Glass Ceramic CAD/CAM crowns and severely altered posterior teeth: a three levels study

被引:5
|
作者
Fages, Michel [1 ]
Corn, Stephane [2 ]
Slangen, Pierre [3 ]
Raynal, Jacques [4 ]
Ienny, Patrick [2 ]
Turzo, Kinga [5 ]
Cuisinier, Frederic [1 ]
Durand, Jean-Cedric [1 ]
机构
[1] Univ Montpellier, LBN, EA4203, Montpellier, France
[2] Ecole Mines Ales, C2MA Mat Ctr, Ales, France
[3] Ecole Mines Ales, LGEI Lab Ind Environm Engn, Ales, France
[4] Univ Montpellier, Dept Prosthodont, Fac Odontol, Montpellier, France
[5] Univ Szeged, Fac Dent, Dept Oral Biol & Expt Dent Res, Szeged, Hungary
关键词
DENTIN;
D O I
10.1007/s10856-017-5948-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For many practitioners, longevity of full glass ceramic crowns in the posterior area, molars and premolars, remains a real challenge. The purpose of this article is to identify and evaluate the parameters that can significantly influence their resistance when preparing a tooth. The analysis proposed in this article relies on interrelated studies conducted at three levels: in vitro (mechanical tests), in silico (finite elements simulations) and in vivo (clinical survival rates). The in vitro and the in silico studies proved that an appropriate variation of the geometric design of the preparations enables to increase up to 80% the mechanical strength of ceramic reconstructions. The in vivo clinical study of CAD/CAM full ceramic crowns was performed in accordance with the principles stated within the in vitro and the in silico studies and provided a 98.97% success rate over a 6 years period. The variations of geometric design parameters for dental preparation allows for reconstructions with a mechanical breaking up to 80% higher than that of a non-appropriate combination. These results are confirmed in clinical practice.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Glass Ceramic CAD/CAM crowns and severely altered posterior teeth: a three levels study
    Michel Fages
    Stephane Corn
    Pierre Slangen
    Jacques Raynal
    Patrick Ienny
    Kinga Turzo
    Frederic Cuisinier
    Jean-Cédric Durand
    Journal of Materials Science: Materials in Medicine, 2017, 28
  • [2] Marginal adaptation of CAD/CAM milled lithium disilicate glass ceramic crowns
    Kojima, K.
    Nagaoka, K.
    Murata, Y.
    Yamamoto, K.
    Akiyama, S.
    Hokii, Y.
    Fusejima, F.
    JOURNAL OF OSSEOINTEGRATION, 2022, 14 (04) : 201 - 204
  • [3] Outcome of chairside CAD/CAM ceramic restorations on endodontically treated posterior teeth: a prospective study
    Hu, Su-Ning
    Li, Jing-Wen
    Zhang, Xi-Xi
    Wei, Rong
    Liang, Yu-Hong
    BMC ORAL HEALTH, 2024, 24 (01)
  • [4] Outcome of chairside CAD/CAM ceramic restorations on endodontically treated posterior teeth: a prospective study
    Su-Ning Hu
    Jing-Wen Li
    Xi-Xi Zhang
    Rong Wei
    Yu-Hong Liang
    BMC Oral Health, 24
  • [5] A clinical evaluation of prefabricated CAD-CAM crowns for restoring anterior and posterior primary teeth
    Hanafi, Louay
    Altinawi, Mohamed
    PEDIATRIC DENTAL JOURNAL, 2020, 30 (03) : 175 - 181
  • [6] SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns
    Ortega, Rocio
    Gonzalo, Esther
    Gomez-Polo, Miguel
    Lopez-Suarez, Carlos
    Suarez, Maria J.
    DENTAL MATERIALS JOURNAL, 2017, 36 (04) : 387 - 393
  • [7] Fracture strength of CAD/CAM posterior ceramic crowns after manual enhancement of occlusal morphology
    Passos, L.
    Torrealba, Y.
    Linke, B.
    Street, A.
    Passos, S.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2018, 21 (03) : 191 - 200
  • [8] Fracture Load of Monolithic CAD/CAM Lithium Disilicate Ceramic Crowns and Veneered Zirconia Crowns as a Posterior Implant Restoration
    Kim, Jee Hwan
    Lee, Su-Jeong
    Park, Jun Sub
    Ryu, Jae Jun
    IMPLANT DENTISTRY, 2013, 22 (01) : 66 - 70
  • [9] Marginal accuracy of CAD/CAM crowns compared to conventional ceramic crowns.
    Runge, J
    Kunzelmann, KH
    Hickel, R
    Perry, R
    Kugel, G
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1244 - 1244
  • [10] CAD/CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study
    Alfarsi, M. A.
    Okutan, H. Mehmet
    Bickel, M.
    AUSTRALIAN DENTAL JOURNAL, 2009, 54 (01) : 12 - 16