Development and application of a broadly reactive real-time reverse transcription-PCR assay for detection of murine noroviruses

被引:62
|
作者
Kitajima, Masaaki [1 ]
Oka, Tomoichiro [2 ]
Takagi, Hirotaka [3 ]
Tohya, Yukinobu [4 ]
Katayama, Hiroyuki [1 ]
Takeda, Naokazu [5 ]
Katayama, Kazuhiko [2 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Urban Engn, Bunkyo Ku, Tokyo 1138656, Japan
[2] Natl Inst Infect Dis, Dept Virol 2, Tokyo 2080011, Japan
[3] Natl Inst Infect Dis, Div Biosafety Control & Res, Tokyo 2080011, Japan
[4] Nihon Univ, Dept Vet Med, Coll Bioresource Sci, Kanagawa 2520880, Japan
[5] Natl Inst Hlth, Res Collaborat Ctr Emerging & Reemerging Infect, Dept Med Sci, Minist Publ Hlth, Muang 11000, Nonthaburi, Thailand
关键词
Murine norovirus; Real-time RT-PCR; Murine stool specimens; In vitro replication; HEPATITIS-A VIRUS; MURINE-NOROVIRUS-1; INFECTION; MICE; INACTIVATION; DIVERSITY; SURROGATE;
D O I
10.1016/j.jviromet.2010.07.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Murine norovirus (MNV) is a viral agent newly identified in laboratory mice and a large number of genetically diverse MNV strains have been reported to date. A broadly reactive TaqMan-based real-time reverse transcription (RT)-polymerase chain reaction (PCR) assay was developed for MNVs. Novel primers and a TaqMan MGB probe were designed targeting highly conserved sequences among MNV strains, which are located in the open reading frames 1 (ORF1)-ORF2 junction region. The quantitative range of this assay was determined as 1.0 x 10(2)-1.0 x 10(8) copies/PCR tube based on a 10-fold serial dilution of plasmid DNA containing the target sequences. Viral RNA in eight murine stool specimens positive by nested RT-PCR assay was measured, and the highest viral RNA load was calculated at 4.7 x 10(6) copies/g-stool. MNV was inoculated into RAW 264.7 cells, and the viral RNA was monitored to validate assay sensitivity. MNV-RNA in the supernatant was detected during in vitro replication, which increased substantially from 5 to 30 h post-infection (hpi) and reached more than 1.0 x 10(10) copies/mL at 96 hpi. This real-time RT-PCR assay is a useful tool to detect and quantify MNV-RNA in in vivo and in vitro studies. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [1] Development of a broadly reactive nested reverse transcription-PCR assay to detect murine noroviruses, and investigation of the prevalence of murine noroviruses in laboratory mice in Japan
    Kitajima, Masaaki
    Oka, Tomoichiro
    Tohya, Yukinobu
    Katayama, Hiroyuki
    Takeda, Naokazu
    Katayama, Kazuhiko
    MICROBIOLOGY AND IMMUNOLOGY, 2009, 53 (09) : 531 - 534
  • [2] Sensitive multiplex real-time reverse transcription-PCR assay for the detection of human and animal noroviruses in clinical and environmental samples
    Wolf, Sandro
    Williamson, Wendy M.
    Hewitt, Joanne
    Rivera-Aban, Malet
    Lin, Susan
    Ball, Andrew
    Scholes, Paula
    Greening, Gail E.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (17) : 5464 - 5470
  • [3] Environmental Detection of Genogroup I, II, and IV Noroviruses by Using a Generic Real-Time Reverse Transcription-PCR Assay
    Miura, Takayuki
    Parnaudeau, Sylvain
    Grodzki, Marco
    Okabe, Satoshi
    Atmar, Robert L.
    Le Guyader, Francoise S.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2013, 79 (21) : 6585 - 6592
  • [4] Real-time reverse transcription-PCR assay for comprehensive detection of human rhinoviruses
    Lu, Xiaoyan
    Holloway, Brian
    Dare, Ryan K.
    Kuypers, Jane
    Yagi, Shigeo
    Williams, John V.
    Hall, Caroline B.
    Erdman, Dean D.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (02) : 533 - 539
  • [5] Broadly reactive and highly sensitive assay for Norwalk-like viruses based on real-time quantitative reverse transcription-PCR
    Kageyama, T
    Kojima, S
    Shinohara, M
    Uchida, K
    Fukushi, S
    Hoshino, FB
    Takeda, N
    Katayama, K
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (04) : 1548 - 1557
  • [6] Detection of equine arteritis virus by real-time TaqMan® reverse transcription-PCR assay
    Balasuriya, UBR
    Leutenegger, CM
    Topol, JB
    McCollum, WH
    Timoney, PJ
    MacLachlan, NJ
    JOURNAL OF VIROLOGICAL METHODS, 2002, 101 (1-2) : 21 - 28
  • [7] Broadly reactive nested reverse transcription-PCR using an internal RNA standard control for detection of noroviruses in stool samples
    Medici, MC
    Martinelli, M
    Ruggeri, FM
    Abelli, LA
    Bosco, S
    Arcangeletti, MC
    Pinardi, F
    De Conto, F
    Calderaro, A
    Chezzi, C
    Dettori, G
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (08) : 3772 - 3778
  • [8] Real-time reverse transcription-PCR assay for detection of mumps virus RNA in clinical specimens
    Boddicker, Jennifer D.
    Rota, Paul A.
    Kreman, Trisha
    Wangeman, Andrea
    Lowe, Louis
    Hummel, Kimberly B.
    Thompson, Robert
    Bellini, William J.
    Pentella, Michael
    DesJardin, Lucy E.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (09) : 2902 - 2908
  • [9] An Improved One-Step Real-Time Reverse Transcription-PCR Assay for Detection of Norovirus
    Glowacka, Ilona
    Harste, Gabrielle
    Witthuhn, Jennifer
    Heim, Albert
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (02) : 497 - 499
  • [10] Development of a Real-Time Reverse Transcription PCR Assay for the Detection of Porcine Kobuvirus
    Liu, Xiao-Wan
    Zhou, Yuan-Chen
    Yang, Fan
    Liu, Meng-Liang
    Zhu, Ling
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MEDICINE AND BIOPHARMACEUTICALS, 2016, : 206 - 216