The effect of different lower detection thresholds in microdosimetric spectra and their mean values

被引:14
|
作者
Bianchi, Anna [1 ,2 ,3 ]
Selva, Anna [3 ]
Colautti, Paolo [3 ]
Parisi, Alessio [1 ]
Vanhavere, Filip [1 ]
Reniers, Brigitte [2 ]
Conte, Valeria [3 ]
机构
[1] SCK CEN, Belgian Nucl Res Ctr, Boeretang 200, B-2400 Boeretang, Belgium
[2] Univ Hasselt, Fac Engn Technol, Ctr Environm Sci, Nucl Technol Ctr, B-3590 Diepenbeek, Belgium
[3] Ist Nazl Fis Nucl INFN, Lab Nazl Legnaro, Viale Univ 2, Padua, Italy
关键词
Microdosimetry; Mini-TEPC; Particle therapy; Linear extrapolation; PROTON-BEAM;
D O I
10.1016/j.radmeas.2021.106626
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Research on the applications of microdosimetry to particle therapy is spreading worldwide with a rapid increase of publications in the last years. In order to be able to perform an intercomparison of data acquired with different detectors in different clinical centres it is important to analyse data with a standard procedure. Often microdosimetric spectra are presented with different lower detection thresholds, in relation with different detection sensitivity and noise levels. The purpose of this paper is to analyse the influence of the lower detection threshold on the dose-mean lineal energy values, which are used as an assessment of the average LET of the radiation field. Furthermore, the dose distribution of the lineal energy can be used in combination with biological weighting functions to estimate the biological RBE at different positions along the penetration depths of therapeutic proton or carbon ion beams. Microdosimetric spectra cut at different lower thresholds lead in principle to different RBE values. It was an additional purpose of this work to analyse and discuss this effect both for proton and carbon ion irradiations. Spectra in proton and carbon ion beams gathered with a miniaturized TEPC developed at the Legnaro National Laboratories of the Italian Institute for Nuclear Physics (LNL-INFN) have been used to perform this study. Linear extrapolation of the microdosimetric spectra to a common value of 0.01 keV/mu m significantly reduces the deviations in the mean values due to different lower thresholds. It is advisable to perform this procedure to have uniformity in data analysis and facilitate the intercomparison of data.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] CONCEPTS OF MICRODOSIMETRY .3. MEAN-VALUES OF MICRODOSIMETRIC DISTRIBUTIONS
    KELLERER, AM
    CHMELEVSKY, D
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1975, 12 (04) : 321 - 335
  • [2] Bilateral olfactory detection thresholds are lower than unilateral olfactory detection thresholds
    Betchen, S
    McKeown, DA
    Lee, WW
    Marcus, A
    Pham, L
    Hebhardt, P
    Doty, RL
    CHEMICAL SENSES, 1995, 20 (06) : 22 - 22
  • [3] Mean inactivity time of lower record values
    Nanda, Phalguni
    Kayal, Suchandan
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2019, 48 (20) : 5145 - 5164
  • [4] Effect of localized defocus on detection thresholds for different sized targets in the fovea and periphery
    Anderson, RS
    McDowell, RD
    Ennis, FA
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (01): : 60 - 63
  • [5] EFFECT OF FOUR DIFFERENT STEP DETECTION THRESHOLDS ON NONMOTORIZED TREADMILL SPRINT MEASUREMENT
    Cronin, John B.
    Rumpf, Michael C.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (10) : 2996 - 3000
  • [6] Comparison of different predicted and lower limit of normal (LLN) values in ventilation disorders detection
    Kameneva, Marina
    Tishkov, Artem
    Bykhova, Alina
    Trofimov, Vasiliy
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [7] The Effect of Conductivity Values on Activation Times and Defibrillation Thresholds
    Johnston, Barbara M.
    Barnes, Josef P.
    Johnston, Peter R.
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 161 - 164
  • [8] The Effect of Fissure Sealants on the Values of Two Different Caries Detection Devices
    Hastar, Esin
    Yildiz, Esma
    Aktan, Ali Murat
    PHOTOMEDICINE AND LASER SURGERY, 2012, 30 (12) : 683 - 687
  • [9] Correlation analyses of detection thresholds of four different odorants
    Zernecke, Rebekka
    Frank, Tilman
    Haegler, Katrin
    Albrecht, Jessica
    Brueckmann, Hartmut
    Wiesmann, Martin
    RHINOLOGY, 2011, 49 (03) : 331 - 336
  • [10] Modelling detection thresholds for sounds repeated at different delays
    Heil, Peter
    Verhey, Jesko L.
    Zoefel, Benedikt