Self-focused ZnO transducers for ultrasonic biomicroscopy

被引:24
|
作者
Cannata, J. M. [1 ]
Williams, J. A. [1 ]
Zhou, Q. F. [1 ]
Sun, L. [1 ]
Shung, K. K. [1 ]
Yu, H. [2 ]
Kim, E. S. [3 ]
机构
[1] Univ So Calif, Dept Biomed Engn, NIH, Res Ctr Med Ultrason Transducer Technol, Los Angeles, CA 90089 USA
[2] Arizona State Univ, Dept Elect Engn, Sch Earth & Space Explorat, Tempe, AZ 85287 USA
[3] Univ So Calif, Dept Elect Engn & Electrophys, Los Angeles, CA 90089 USA
关键词
D O I
10.1063/1.2907716
中图分类号
O59 [应用物理学];
学科分类号
摘要
A simple fabrication technique was developed to produce high frequency (100 MHz) self-focused single element transducers with sputtered zinc oxide (ZnO) crystal films. This technique requires the sputtering of a ZnO film directly onto a curved backing substrate. Transducers were fabricated by sputtering an 18 mu m thick ZnO layer on 2 mm diameter aluminum rods with ends shaped and polished to produce a 2 mm focus or f-number equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A 4 mu m Parylene matching layer was deposited on the transducers after housing and interconnect. This matching layer was used to protect the substrate and condition the transfer of acoustic energy between the ZnO film and the load medium. The pulse-echo response for a representative transducer was centered at 101 MHz with a -6 dB bandwidth of 49%. The measured two way insertion loss was 44 dB. A tungsten wire phantom and an adult zebrafish eye were imaged to show the capability of these transducers. (c) 2008 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Self-focused ZnO transducers for ultrasonic biomicroscopy
    Cannata, J. M.
    Williams, J. A.
    Zhou, Q.
    Yu, H.
    Sun, L.
    Kim, E. S.
    Shung, K. Y.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 945 - +
  • [2] Self-focused high frequency ultrasonic transducers based on ZnO piezoelectric films
    Zhou, Q. F.
    Sharp, C.
    Cannata, J. M.
    Shung, K. K.
    Feng, G. H.
    Kim, E. S.
    [J]. APPLIED PHYSICS LETTERS, 2007, 90 (11)
  • [3] 200 MHz self-focused ZnO MEMS ultrasonic transducers for biomedical imaging
    Sharp, CC
    Feng, GH
    Zhou, QF
    Cannata, JM
    Kim, ES
    Shung, KK
    [J]. 2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1946 - 1949
  • [4] Acoustic Power Transfer Using Self-Focused Transducers for Miniaturized Implantable Neurostimulators
    Kim, Kyungmin
    Jang, Seok Geun
    Lim, Hae Gyun
    Kim, Hyung Ham
    Park, Sung-Min
    [J]. IEEE ACCESS, 2021, 9 : 153850 - 153862
  • [5] Lead-free self-focused piezoelectric transducers for viscous liquid ejection
    Kwok, K. W.
    Hon, S. F.
    Lin, Dunmin
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2011, 168 (01) : 168 - 171
  • [6] Research on nonlinear effects of sound fields induced by self-focused concave spherical transducers
    College of Physics and Information Science, Hunan Normal University, Changsha 410081, China
    [J]. Yadian Yu Shengguang, 2007, 6 (720-722):
  • [7] FORMATION OF SELF-FOCUSED BEAM
    LAUER, EJ
    LEARY, JM
    BAUER, RW
    BRIGGS, RJ
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (11): : 982 - 982
  • [8] The Self-focused Practice Questionnaire (SfPQ): Preliminary Psychometric Properties of a Measure of Therapist Self-focused Practice
    Chigwedere, Craig
    Fitzmaurice, Brian
    Donohoe, Gary
    [J]. BEHAVIOURAL AND COGNITIVE PSYCHOTHERAPY, 2017, 45 (05) : 497 - 509
  • [9] DYSPHORIA AND SPECIFICITY IN SELF-FOCUSED ATTENTION
    CONWAY, M
    GIANNOPOULOS, C
    CSANK, P
    MENDELSON, M
    [J]. PERSONALITY AND SOCIAL PSYCHOLOGY BULLETIN, 1993, 19 (03) : 265 - 268
  • [10] SELF-FOCUSED ATTENTION AND BELIEF PERSEVERANCE
    DAVIES, MF
    [J]. JOURNAL OF EXPERIMENTAL SOCIAL PSYCHOLOGY, 1982, 18 (06) : 595 - 605