Preanalytical conditions of point-of-care testing in the intensive care unit are decisive for analysis reliability

被引:24
|
作者
Auvet, Adrien [1 ,2 ,3 ]
Espitalier, Fabien [2 ]
Grammatico-Guillon, Leslie [4 ]
Nay, Mai-Anh [1 ,2 ,3 ]
Elaroussi, Djilali [2 ]
Laffon, Marc [2 ,3 ]
Andres, Christian R. [3 ,5 ]
Legras, Annick [1 ]
Ehrmann, Stephan [1 ,3 ,6 ]
Dequin, Pierre-Francois [1 ,3 ,6 ]
Gendrot, Chantal [5 ]
Guillon, Antoine [1 ,3 ,6 ]
机构
[1] CHRU Tours, Serv Reanimat Polyvalente, 2 Blvd Tonnelle, F-37000 Tours, France
[2] CHRU Tours, Dept Anesthesie & Reanimat, 2 Blvd Tonnelle, F-37000 Tours, France
[3] Univ Tours, Fac Med, 10 Blvd Tonnelle, F-37032 Tours, France
[4] CHRU Tours, Hop Bretonneau, Serv Informat Med Epidemiol & Econ Sante, 2 Blvd Tonnelle, F-37000 Tours, France
[5] CHRU Tours, Biochim Lab, 2 Blvd Tonnelle, F-37000 Tours, France
[6] INSERM, Ctr Etud Pathol Resp, U1100, 10 Bd Tonnelle, F-37032 Tours, France
来源
关键词
Point-of-care testing; Preanalytical; Intensive care; Electrolyte; Hemoglobin; BLOOD-GAS ANALYZERS; EMERGENCY-DEPARTMENT; WHOLE-BLOOD; HEMOGLOBIN; ELECTROLYTE; POTASSIUM; HEMATOLOGY; DIFFERENCE; CHEMISTRY; SYRINGES;
D O I
10.1186/s13613-016-0152-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Point-of-care testing (POCT) systems enable a wide range of tests to be rapidly performed at the bedside and have attracted increasing interest in the intensive care unit (ICU). However, previous studies comparing the concordance of POCT with central laboratory testing have reported divergent findings. Most reported studies on POCT reliability have focused on analyzer performance rather than the preanalytical phase. The aim of this study was to assess the reliability of results provided by point-of-care analyzers according to the organization of the care units and the preanalytical process. In three adult critical care units, 491 paired blood samples were analyzed for hemoglobin, potassium, and sodium concentrations by blood gas analyzers (identical reference) and the central laboratory. The clinical significance of agreement was assessed using Bland-Altman plots. A quality improvement program was then implemented to improve the preanalytical POCT process for one ICU where there was poor agreement. A second comparison was performed on 278 paired blood samples in this unit. Biases were clinically nonsignificant for potassium and sodium concentrations for all tested critical care units, relative to the reference method. However, biases [limits of agreements] for hemoglobin analyses were clearly affected by the preanalytical process: -3 [-6; 1] g/L in the operating room, -5 [-28; 17] g/L in a 10-bed ICU, and -19 [-64; 27] g/L in a 37-bed ICU. The quality approach was implemented in the 37-bed ICU and led to corrective actions that: (1) reduced the time for the POCT preanalytical phase; (2) implemented a checklist to validate the preanalytical conditions; (3) used technical innovations. The improvement of the preanalytical process resulted in a substantial decrease of the bias for hemoglobin concentration measurements: -3 [-10; 5] g/L in the 37-bed ICU. We clearly demonstrate that an identical analyzer can provide results of varying quality depending on the local constraints of the ICUs. We demonstrate that quality management focused on the preanalytical process and performed by the partners involved in the POCT can overcome these issues.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Preanalytical conditions of point-of-care testing in the intensive care unit are decisive for analysis reliability
    Adrien Auvet
    Fabien Espitalier
    Leslie Grammatico-Guillon
    Mai-Anh Nay
    Djilali Elaroussi
    Marc Laffon
    Christian R. Andres
    Annick Legras
    Stephan Ehrmann
    Pierre-François Dequin
    Chantal Gendrot
    Antoine Guillon
    [J]. Annals of Intensive Care, 6
  • [2] Point-of-care Testing of Coagulation in Intensive Care Unit: Role of Thromboelastography
    Govil, Deepak
    Pal, Divya
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2019, 23 : S202 - S206
  • [3] POINT-OF-CARE TESTING IN THE INTENSIVE-CARE UNIT - THE INTENSIVE-CARE PHYSICIANS PERSPECTIVE
    CASTRO, HJ
    OROPELLO, JM
    HALPERN, N
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (04) : S95 - S99
  • [4] Point-of-Care Ultrasound in the Intensive Care Unit
    Campbell, Steven J.
    Bechara, Rabih
    Islam, Shaheen
    [J]. CLINICS IN CHEST MEDICINE, 2018, 39 (01) : 79 - +
  • [5] ECONOMIC EVALUATION OF BLOOD GLUCOSE POINT-OF-CARE TESTING IN THE INTENSIVE CARE UNIT
    Steuten, L. M. G.
    Kip, M.
    Hooijdonk, R.
    Monteban, H.
    Spronk, P.
    Schultz, M.
    [J]. VALUE IN HEALTH, 2014, 17 (03) : A250 - A250
  • [6] Point-of-care blood testing and cardiac output measurement in the intensive care unit
    Shapiro, BA
    [J]. NEW HORIZONS-THE SCIENCE AND PRACTICE OF ACUTE MEDICINE, 1999, 7 (02): : 244 - 252
  • [7] Point-of-Care Ultrasound in the Pediatric Intensive Care Unit
    Burton, Luke
    Bhargava, Vidit
    Kong, Michele
    [J]. FRONTIERS IN PEDIATRICS, 2022, 9
  • [8] Pulmonary Point-of-Care Ultrasonography in the Intensive Care Unit
    Gayen, Shameek
    Kim, Jin Sun
    Desai, Parag
    [J]. AACN ADVANCED CRITICAL CARE, 2023, 34 (02) : 113 - 118
  • [9] Finger Prick for Point-of-Care Testing: Issue on Preanalytical Control
    Wiwanitkit, Viroj
    [J]. POINT OF CARE, 2012, 11 (02): : 90 - 90
  • [10] Point-of-care ultrasound: Infection control in the intensive care unit
    Lichtenstein, Daniel A.