Comparing, with the other air conditioning systems, liquid desiccant air conditioning system is able to transfer and store its energy as chemic energy to achieve the dense energy-storage. It has the advantages like energy losing caused by treating the temperature and humidity of air at the same time. Since having, no pollution and saves power, it will become a new kind of environmental-friendly refrigerating function with a splendid prospect. Still, this system needs to be optimized. This article shows the research in the optimization on the use of energy during the treatment of air and solution and the exchange of heal and mass, etc., in order to make reasonable use of energy sources and save energy sources, so that the liquid desiccant air conditioning can be used better and more widely.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
  • [1] Design of ionic liquids as a desiccant for the liquid desiccant type air conditioning system
    Itoh, Toshiyuki
    Kim, Hyung J.
    [J]. CHEMISTRY LETTERS, 2024, 53 (09)
  • [2] Design of ionic liquids as liquid desiccant for an air conditioning system
    Haruki Watanabe
    Takuro Komura
    Ryo Matsumoto
    Kenta Ito
    Hiroshi Nakayama
    Toshiki Nokami
    Toshiyuki Itoh
    [J]. Green Energy & Environment, 2019, 4 (02) : 139 - 145
  • [3] Design of ionic liquids as liquid desiccant for an air conditioning system
    Watanabe, Haruki
    Komura, Takuro
    Matsumoto, Ryo
    Ito, Kenta
    Nakayama, Hiroshi
    Nokami, Toshiki
    Itoh, Toshiyuki
    [J]. GREEN ENERGY & ENVIRONMENT, 2019, 4 (02) : 139 - 145
  • [4] A comprehensive review of liquid desiccant air conditioning system
    Gurubalan, A.
    Maiya, M. P.
    Geoghegan, Patrick J.
    [J]. APPLIED ENERGY, 2019, 254
  • [5] Liquid desiccant air conditioning system with natural convection
    Fazilati, Mohammad Ali
    Alemrajabi, Ali Akbar
    Sedaghat, Ahmad
    [J]. APPLIED THERMAL ENGINEERING, 2017, 115 : 305 - 314
  • [6] PERFORMANCE OPTIMIZATION OF LIQUID DESICCANT AIR-CONDITIONING PROCESSES
    Jiang, J. J.
    Liu, X. H.
    Zhang, T.
    Zhang, L.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 745 - 750
  • [7] Factor analysis and optimization of operational parameters in a liquid desiccant air-conditioning system
    Tu, Min
    Huang, Hui
    Liu, Ze-Hua
    Chen, Huan-Xin
    Ren, Cheng-Qin
    Chen, Guo-Jie
    Hu, Yan
    [J]. ENERGY, 2017, 139 : 767 - 781
  • [8] ENERGY ANALYSIS OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH VARIABLE TEMPERATURE AND HUMIDITY DESIGN
    Xu, Guiquan
    Pei, Qingqing
    Li, Fangyan
    Liao, Zhu
    Chen, Yujian
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1957 - 1964
  • [9] Analysis and modeling of solar liquid desiccant air conditioning system
    Fang, Chengchao
    Sun, Ketao
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1997, 18 (02): : 128 - 133
  • [10] Control strategies for a liquid desiccant air-conditioning system
    Ge, Gaoming
    Xiao, Fu
    Niu, Xiaofeng
    [J]. ENERGY AND BUILDINGS, 2011, 43 (06) : 1499 - 1507