A New Type of Portable Micro-X-Ray Fluorescence Spectrometer with Polycapillary Optics

被引:6
|
作者
Duan Ze-ming [1 ,2 ,3 ]
Liu Jun [1 ,2 ,3 ]
Jiang Qi-li [1 ,2 ,3 ]
Pan Qiu-li [1 ,2 ,3 ]
Li Rong-wu [1 ,2 ,3 ]
Cheng Lin [1 ,2 ,3 ]
机构
[1] Beijing Normal Univ, Coll Nucl Sci & Technol, Key Lab Beam Technol, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, Coll Nucl Sci & Technol, Minist Educ, Beijing 100875, Peoples R China
[3] Beijing Radiat Ctr, Beijing 100875, Peoples R China
关键词
Polycapillary optics; X-ray fluorescence; Portable X-ray fluorescence spectrometer; Micro -X-ray fluorescence; Laser displacement sensor; Ancient porcelain; MA-XRF;
D O I
10.3964/j.issn.1000-0593(2019)01-0303-07
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The portable micro-X-ray fluorescence analysis with polycapillary optics has advantages of being non-destructive, and it has been widely used in the analysis of cultural relics. However, due to the irregular or curving surface of archaeological objects and the shortcoming of polycapillary optics in focusing X-rays, the distances between the irradiation spot of samples and exit of polycapillary optics are variables. As a result, the sizes of focused X-ray spot cant keep constant, which reduces the accuracy of measurement and the resolution of elemental mappings of scanning area. In this paper, we propose a new type of portable micro -X-ray fluorescence spectrometer that consists of a new closed loop feedback system and SDD X-ray detector, 30W lower power X-ray tube, polycapillary optics, CCD and so on. In particularly, the closed loop feedback system is composed of Laser Displacement Sensor (LDS) stepper motor, sample stage and computer programs developed by LabVIEW languages. During measuring, the LDS accurately controls the distances between the irradiation spot of samples and exit of polycapillary optics. Based on this closed loop feedback system, our portable micro X-ray fluorescence spectrometer can keep the sizes of focused X-ray spot constant. On the other hand, we provide different alternative sizes of focused X-ray spot by controlling the distances between the exit of polycapillary optics and measured spot of samples in our spectrometer. In order to test the feasibility of this instrument, the concentration of elements and elemental mappings of K, Ca, Zn, Fe and other elements in the irregular colored glaze of a piece of ancient porcelain have been measured by our portable micro X-ray fluorescence spectrometer under enabling and disabling LDS conditions. From the results, it can be concluded that the concentration of elements is very close to the real values and the resolution of elemental mappings is better when LDS is enabled. This indicates that the closed loop feedback system based on LDS can accurately reduce the measurement errors caused by the irregular or curving surface of archaeological objects. Therefore, this portable micro X-ray fluorescence spectrometer developed by our laboratory has potential application prospects in nondestructive analysis of cultural relics.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 14 条
  • [1] Optimization of mobile scanning macro-XRF systems for the in situ investigation of historical paintings
    Alfeld, Matthias
    Janssens, Koen
    Dik, Joris
    de Nolf, Wout
    van der Snickt, Geert
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (05) : 899 - 909
  • [2] Characterization of X-ray polycapillary optics by LiF crystal radiation detectors through confocal fluorescence microscopy
    Bonfigli, Francesca
    Hampai, Dariush
    Dabagov, Sultan B.
    Montereali, Rosa Maria
    [J]. OPTICAL MATERIALS, 2016, 58 : 398 - 405
  • [3] Micro-XRF analysis of silver coins from medieval Poland
    del Hoyo-Melendez, Julio M.
    Swit, Pawel
    Matosz, Marta
    Wozniak, Mateusz
    Klisinska-Kopacz, Anna
    Bratasz, Lukasz
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 349 : 6 - 16
  • [4] Enamel paint techniques in archaeology and their identification using XRF and micro-XRF
    Hlozek, M.
    Trojek, T.
    Komoroczy, B.
    Prokes, R.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 243 - 247
  • [5] Lin C, 2011, NUCL INSTRUMENTS M B, V269, P239
  • [6] A novel approach to varve counting using μXRF and X-radiography in combination with thin-section microscopy, applied to the Late Glacial chronology from Lake Suigetsu, Japan
    Marshall, Michael
    Schlolaut, Gordon
    Nakagawa, Takeshi
    Lamb, Henry
    Brauer, Achim
    Staff, Richard
    Ramsey, Christopher Bronk
    Tarasov, Pavel
    Gotanda, Katsuya
    Haraguchi, Tsuyoshi
    Yokoyama, Yusuke
    Yonenobu, Hitoshi
    Tada, Ryuji
    [J]. QUATERNARY GEOCHRONOLOGY, 2012, 13 : 70 - 80
  • [7] Using micro X-ray fluorescence to image chloride profiles in concrete
    Moradllo, Mehdi Khanzadeh
    Sudbrink, Bryan
    Hu, Qinang
    Aboustait, Mohammed
    Tabb, Braden
    Ley, M. Tyler
    Davis, Jeffrey M.
    [J]. CEMENT AND CONCRETE RESEARCH, 2017, 92 : 128 - 141
  • [8] Elemental mapping of biofortified wheat grains using micro X-ray fluorescence
    Ramos, I.
    Pataco, I. M.
    Mourinho, M. P.
    Lidon, F.
    Reboredo, F.
    Pessoa, M. F.
    Carvalho, M. L.
    Santos, J. P.
    Guerra, M.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 120 : 30 - 36
  • [9] Macro X-ray fluorescence (MA-XRF) scanning of illuminated manuscript fragments: potentialities and challenges
    Ricciardi, Paola
    Legrand, Stijn
    Bertolotti, Giulia
    Janssens, Koen
    [J]. MICROCHEMICAL JOURNAL, 2016, 124 : 785 - 791
  • [10] Macro X-ray fluorescence scanning (MA-XRF) as tool in the authentication of paintings
    Saverwyns, Steven
    Currie, Christina
    Lamas-Delgado, Eduardo
    [J]. MICROCHEMICAL JOURNAL, 2018, 137 : 139 - 147