Coronary sinus lead extraction in the era of cardiac resynchronization therapy: Single center experience

被引:31
|
作者
Kasravi, B
Tobias, S
Barnes, MJ
Messenger, JC
机构
[1] Long Beach Mem Med Ctr, Mem Heart Inst, Mem Cardiol Med Grp, Long Beach, CA 90806 USA
[2] Univ Calif Irvine, Irvine Med Ctr, Orange, CA 92668 USA
来源
关键词
coronary sinus; lead extraction; resynchronization;
D O I
10.1111/j.1540-8159.2005.09353.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
As the number of coronary sinus (CS) lead implantations for cardiac resynchronization therapy increases so will the need for extraction of these leads. The safety of extraction of leads from the branches of the CS has not been reported. We reviewed our database of patients undergoing pacemaker lead extraction from January 2002 through February 2004 at our institution, Of 149 patients referred for lead extraction, 14 (9%) had a biventricular device. The indications for lead extraction were infection.. lead malfunction, and exit block. The duration of CS lead implants ranged between 2 and 43 months (mean 17 months). All 14 CS leads were removed successfully using nonsurgical lead extraction techniques. Three leads that were in place the longest (greater than or equal to 27 months) were removed via the femoral vein approach due to fibrous attachment of the CS lead body to the other pacemaker leads. The leads were structurally intact and without any significant fibrosis of their tips upon visual inspection. There were no major complications of CS laceration, hypotension, pericardial effusion, or excessive blood loss associated with any of the extraction procedures. CS leads were removed safely, successfully and with relative ease based on our experience in this small cohort of patients.
引用
下载
收藏
页码:51 / 53
页数:3
相关论文
共 50 条
  • [1] Extraction of Coronary Sinus Lead: A Large Single Center Experience
    Carrillo, Roger G.
    Garisto, Juan D.
    CIRCULATION, 2010, 122 (21)
  • [2] Results of transvenous lead extraction of coronary sinus leads in patients with cardiac resynchronization therapy
    Starck, Christoph T.
    Caliskan, Etem
    Klein, Holger
    Steffel, Jan
    Schoenrath, Felix
    Falk, Volkmar
    CHINESE MEDICAL JOURNAL, 2013, 126 (24) : 4703 - 4706
  • [3] Results of transvenous lead extraction of coronary sinus leads in patients with cardiac resynchronization therapy
    Christoph T.Starck
    Etem Caliskan
    Holger Klein
    Jan Steffel
    Felix Schoenrath
    Volkmar Falk
    中华医学杂志(英文版), 2013, 126 (24) : 4703 - 4706
  • [4] Single-center experience of a quadripolar pacing lead for cardiac resynchronization therapy
    Antonello Vado
    Endrj Menardi
    Guido Rossetti
    Gianpaolo Ballari
    Mauro Feola
    Marco Bobbio
    Journal of Interventional Cardiac Electrophysiology, 2014, 39 : 161 - 165
  • [5] Single-center experience of a quadripolar pacing lead for cardiac resynchronization therapy
    Vado, Antonello
    Menardi, Endrj
    Rossetti, Guido
    Ballari, Gianpaolo
    Feola, Mauro
    Bobbio, Marco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (02) : 161 - 165
  • [6] Initial Single-Center Experience of a Quadripolar Pacing Lead for Cardiac Resynchronization Therapy
    Shetty, Anoop K.
    Duckett, Simon G.
    Bostock, Julian
    Roy, Debashis
    Ginks, Matthew
    Hamid, Shoaib
    Rosenthal, Eric
    Razavi, Reza
    Rinaldi, Christopher Aldo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (04): : 484 - 489
  • [7] Percutaneous Lead and System Extraction in Patients with Cardiac Resynchronization Therapy (CRT) Devices and Coronary Sinus Leads
    Williams, Steven E.
    Arujuna, Aruna
    Whitaker, John
    Shetty, Anoop K.
    Bostock, Julian
    Patel, Nikhil
    Mobb, Margaret
    Cooklin, Mike
    Gill, Jaswinder
    Blauth, Christopher
    Bucknall, Cliff
    Hamid, Shoaib
    Rinaldi, C. Aldo.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (10): : 1209 - 1216
  • [8] Cardiac resynchronization therapy coronary venous left ventricular lead removal and reimplantation: Experience from a single center in China
    Zheng, Wencheng
    Li, Ding
    Li, Xuebin
    Ze, Feng
    Wang, Long
    Duan, Jiangbo
    Yuan, Cuizhen
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 18 (03) : 2213 - 2218
  • [9] Clinical predictors of incomplete coronary sinus lead removal during transvenous lead extraction in patients with cardiac resynchronization therapy
    Hayashi, Katsuhide
    Younis, Arwa
    Callahan, Thomas
    Baranowski, Bryan
    Martin, David O.
    Nakhla, Shady
    Wilkoff, Bruce L.
    HEART RHYTHM, 2023, 20 (06) : 872 - 878
  • [10] Cardiac Resynchronization Therapy- Single center experience in Nepal
    Raut, Roshan
    Bahadur, Man K. C.
    Rajbhandari, Sujeeb
    Dhungana, Murari
    Sharma, Mukunda
    Joshi, Surakshya
    Bajracharya, Prashant
    NEPALESE HEART JOURNAL, 2019, 16 (02) : 5 - 9