Design of a Multiband Near-infrared Sky Brightness Monitor

被引:0
|
作者
Jiang, Feng-xin [1 ]
Chen, Jie [1 ]
Dong, Shu-cheng [1 ]
Tang, Qi-Jie [1 ]
Chen, Jin-ting [1 ]
Zhang, Yi-hao [1 ]
Wang, Zhi-yue [1 ]
Chen, Yaqi [1 ]
Zhang, Hong-fei [1 ]
Jiang, Hai-jiao [3 ]
Zhu, Qing-feng [2 ]
Jiang, Peng [4 ]
Ji, Tuo [4 ]
Wang, Jian [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, State Key Lab Technol Particle Detect & Elect, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Univ Sci & Technol China, Dept Astron, Hefei 230026, Anhui, Peoples R China
[3] Chinese Acad Sci, Nanjing Inst Astron Opt & Technol, Natl Astron Observ, Nanjing 210042, Jiangsu, Peoples R China
[4] Polar Res Inst China, Shanghai 200136, Peoples R China
关键词
Near infrared; Sky background radiation; InSb detector; FILTER SET;
D O I
10.1117/12.2309842
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Infrared sky background level is an important parameter of grounded infrared astronomy observations, which should be firstly measured in a good infrared observatory site, and only the site with low background level is suitable for infrared observations. Infrared sky background level can provide background data for the design of related infrared instruments. However, there is no such data available for major sites in China. Based on the requirement, In order to supplement the current site survey data and guide the design of future infrared instruments, a multiband near-infrared sky brightness monitor (MNISBM) based on an InSb sensor is designed in this paper. The MNISBM consists of optical system, mechanical structure and control system, detector and cooler, high gain readout electronic system, operational software. It is completed and carried out an experimental measurement in the laboratory. The result shows that the sensitivity of the MNISBM meets the requirements of the measurement of near-infrared sky background level.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Design of a multiband near-infrared sky brightness monitor using an InSb detector
    Dong, Shu-cheng
    Wang, Jian
    Tang, Qi-jie
    Jiang, Feng-xin
    Chen, Jin-ting
    Zhang, Yi-hao
    Wang, Zhi-yue
    Chen, Jie
    Zhang, Hong-fei
    Jiang, Hai-jiao
    Zhu, Qing-feng
    Jiang, Peng
    Ji, Tuo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (02):
  • [2] Design of a near-infrared sky brightness monitor and field measurement at the Ngari Observatory, Tibet
    Tang, Qi-Jie
    Wang, Jian
    Dong, Shu-Cheng
    Chen, Jin-Ting
    Zhang, Yi-Hao
    Jiang, Feng-Xin
    Wang, Zhi-Yue
    Chen, Ya-Qi
    Jia, Ming-Hao
    Chen, Jie
    Zhang, Hong-Fei
    Zhu, Qing-Feng
    Jiang, Peng
    Ji, Tuo
    Zhang, Shao-Hua
    Yao, Yong-Qiang
    Zhou, Yun-He
    Wang, Hong-Shuai
    Tang, Peng
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2018, 4 (04)
  • [3] Design of Near Infrared Sky Brightness Monitor for measurements in Antarctica
    Zhang, Jun
    Tang, Qi-jie
    Wang, Jian
    Chen, Jin-ting
    Zhang, Yi-hao
    Wang, Zhi-yue
    Chen, Ya-qi
    Zhang, Qian
    Jia, Ming-hao
    Zhang, Guang-yu
    Chen, Jie
    Jiang, Feng-xin
    Zhang, Hong-fei
    Zhu, Qing-feng
    Jiang, Peng
    Ji, Tuo
    Zhang, Shao-hua
    ASTRONOMICAL OPTICS: DESIGN, MANUFACTURE, AND TEST OF SPACE AND GROUND SYSTEMS II, 2019, 11116
  • [4] The south pole near-infrared sky brightness
    Nguyen, HT
    Rauscher, BJ
    Severson, SA
    Hereld, M
    Harper, DA
    Loewenstein, RF
    Mrozek, F
    Pernic, RJ
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1996, 108 (726) : 718 - 720
  • [5] Design of EPICS and Web-Based Remote Control Software of Near-Infrared Sky Brightness Monitor in Antarctica
    Wang, Zhi-Yue
    Wang, Jian
    Chen, Ya-Qi
    Jia, Ming-Hao
    Zhang, Guang-Yu
    Tang, Qi-Jie
    Chen, Jin-Ting
    Zhang, Yi-Hao
    Zhang, Jun
    Zhang, Hong-Fei
    Chen, Jie
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (08) : 1998 - 2004
  • [6] Design of an extended area blackbody for calibration of near infrared sky brightness monitor in the Antarctic
    Feng, Qi
    Chen, Jin-ting
    Tang, Qi-Jie
    Zhang, Jun
    Zhang, Yi-hao
    Wang, Xing-bo
    Chen, Jie
    Zhang, Hong-fei
    Wang, Jian
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY IX, 2020, 11454
  • [7] South Pole observations of the near-infrared sky brightness
    Ashley, MCB
    Burton, MG
    Storey, JWV
    Lloyd, JP
    Bally, J
    Briggs, JW
    Harper, DA
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1996, 108 (726) : 721 - 723
  • [8] A ROCKET-BORNE OBSERVATION OF THE NEAR-INFRARED SKY BRIGHTNESS
    MATSUURA, S
    KAWADA, M
    MATSUHARA, H
    MATSUMOTO, T
    NODA, M
    TANAKA, M
    BOCK, JJ
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1994, 106 (701) : 770 - 779
  • [9] n Characterizing Near-Infrared Sky Brightness in the Canadian High Arctic
    Sivanandam, Suresh
    Graham, James R.
    Abraham, Roberto
    Tekatch, Anthony
    Steinbring, Eric
    Ngan, Wayne
    Welch, Doug L.
    Law, Nicholas M.
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY IV, 2012, 8446
  • [10] Preliminary results of sky brightness measurements in near-infrared at Lenghu, China
    Li, Jinji
    Ma, Bin
    Dong, Zhongnan
    Zhang, Haoran
    GROUND-BASED AND AIRBORNE TELESCOPES X, 2024, 13094