Noninvasive temperature and velocity mapping using magnetic resonance imaging

被引:0
|
作者
Jiang, Lanlan [1 ]
Zhou, Xinhuan [2 ]
Liu, Yu [1 ]
Song, Yongchen [1 ]
Zhao, Yuechao [1 ]
Wu, Bohao [1 ]
Teng, Ying [1 ]
机构
[1] Dalian Univ Technol, Key Lab Ocean Energy Utilizat & Energy Conservat, Minist Educ, Dalian 116024, Liaoning, Peoples R China
[2] AVIC Commercial Aircraft Engine CO LTD, Shanghai 200241, Peoples R China
基金
中国国家自然科学基金;
关键词
CO2 capture and storage; MRI; Temperature measurement; Velocity measurement; Inversion recovery tagging method; APPARENT DIFFUSION-COEFFICIENT; PROTON CHEMICAL-SHIFT; IN-VIVO; WATER; LIVER; DEPENDENCE; BRAIN; MAPS;
D O I
10.1007/s12650-015-0326-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate temperature and velocity measurement of fluid is of vital importance for CO2 Capture and Storage (CCS). The aims of this study were to evaluate the application of several magnetic resonance imaging (MRI) temperature measurement techniques in CCS and to simultaneously measure velocity and temperature distribution for flow field. First, the relations between MRI parameters including apparent self-diffusion coefficient (D), longitudinal relaxation time (T (1)), longitudinal equilibrium magnetization (M (0)) and temperature for three different samples were investigated. The results show that in high magnetic strength field the linear relationship between D and temperature is better than M (0)-T and T (1)-T in terms of accuracy and sensitivity. Then we used inversion recovery tagging method to simultaneously measure temperature and velocity of water flowing through a heated vessel. Temperature measured by IR-tagging method is within a deviation of 2 A degrees C from the numerical results obtained by computational fluid dynamics.
引用
收藏
页码:403 / 415
页数:13
相关论文
共 50 条
  • [1] Noninvasive temperature and velocity mapping using magnetic resonance imaging
    Lanlan Jiang
    Xinhuan Zhou
    Yu Liu
    Yongchen Song
    Yuechao Zhao
    Bohao Wu
    Ying Teng
    Journal of Visualization, 2016, 19 : 403 - 415
  • [2] Temperature mapping with magnetic resonance imaging
    Feng, Suyun
    Peng, Yuhua
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 604 - 608
  • [3] NONINVASIVE MAPPING OF OCULAR OXYGENATION USING STANDARD MAGNETIC-RESONANCE-IMAGING
    BERKOWITZ, BA
    WILSON, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S105 - S105
  • [4] Glass transition temperature mapping using magnetic resonance imaging
    Ruan, RR
    Long, Z
    Chang, K
    Chen, PL
    Taub, IA
    TRANSACTIONS OF THE ASAE, 1999, 42 (04): : 1055 - 1059
  • [5] Magnetic Resonance Imaging and Velocity Mapping in Chemical Engineering Applications
    Gladden, Lynn F.
    Sederman, Andrew J.
    ANNUAL REVIEW OF CHEMICAL AND BIOMOLECULAR ENGINEERING, VOL 8, 2017, 8 : 227 - 247
  • [6] TEMPERATURE MAPPING IN A MODEL FOOD GEL USING MAGNETIC-RESONANCE-IMAGING
    SUN, XZ
    LITCHFIELD, JB
    SCHMIDT, SJ
    JOURNAL OF FOOD SCIENCE, 1993, 58 (01) : 168 - &
  • [7] A TECHNIQUE FOR VELOCITY IMAGING USING MAGNETIC-RESONANCE-IMAGING
    RIDGWAY, JP
    SMITH, MA
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 822 - 822
  • [8] A TECHNIQUE FOR VELOCITY IMAGING USING MAGNETIC-RESONANCE-IMAGING
    RIDGWAY, JP
    SMITH, MA
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (702): : 603 - 607
  • [9] Advances in magnetic resonance imaging: cine MRI and flow velocity mapping
    Flamm, SD
    Moodie, DS
    PROGRESS IN PEDIATRIC CARDIOLOGY, 1997, 7 (03) : 117 - 129
  • [10] Mapping analysis of brain tissue temperature by magnetic resonance imaging
    Cadoux-Hudson, TAD
    BRAIN HYPOTHERMIA: PATHOLOGY, PHARMACOLOGY, AND TREATMENT OF SEVERE BRAIN INJURY, 2000, : 109 - 112