Diagnostic performance of quantitative coronary artery disease assessment using computed tomography in patients with aortic stenosis undergoing transcatheter aortic-valve implantation

被引:9
|
作者
Malebranche, Daniel [1 ]
Hoffner, Maximilian K. M. [2 ]
Huber, Adrian T. [2 ]
Cicovic, Aleksandar [1 ]
Spano, Giancarlo [1 ]
Bernhard, Benedikt [1 ]
Bartkowiak, Joanna [1 ]
Okuno, Taishi [1 ]
Lanz, Jonas [1 ]
Raber, Lorenz [1 ]
Praz, Fabien [1 ]
Stortecky, Stefan [1 ]
Windecker, Stephan [1 ]
Pilgrim, Thomas [1 ]
Grani, Christoph [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept Diagnost Intervent & Pediat Radiol, Inselspital, Bern, Switzerland
关键词
Transcatheter aortic valve replacement; Computed tomography angiography; CTA; TAVI; CAD; Coronary artery disease; QCA; Invasive angiography; CT ANGIOGRAPHY; TASK-FORCE; ACCURACY; CALCIUM; REPLACEMENT;
D O I
10.1186/s12872-022-02623-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. Methods In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. >= 50% stenosis). Results 100 consecutive patients were retrospectively included, age was 82.3 +/- 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. Conclusion In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Diagnostic performance of quantitative coronary artery disease assessment using computed tomography in patients with aortic stenosis undergoing transcatheter aortic-valve implantation
    Daniel Malebranche
    Maximilian K. M. Hoffner
    Adrian T. Huber
    Aleksandar Cicovic
    Giancarlo Spano
    Benedikt Bernhard
    Joanna Bartkowiak
    Taishi Okuno
    Jonas Lanz
    Lorenz Räber
    Fabien Praz
    Stefan Stortecky
    Stephan Windecker
    Thomas Pilgrim
    Christoph Gräni
    BMC Cardiovascular Disorders, 22
  • [2] Prevalence of coronary artery disease among patients with bicuspid aortic valve stenosis undergoing computed tomography before transcatheter aortic valve implantation
    Wiessman, M.
    Aviv, Y.
    Shafir, G.
    Kornowski, R.
    Hamdan, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 202 - 202
  • [3] Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation
    Meier, David
    Depierre, Arnaud
    Topolsky, Antoine
    Roguelov, Christan
    Dupre, Marion
    Rubimbura, Vladimir
    Eeckhout, Eric
    Qanadli, Salah Dine
    Muller, Olivier
    Mahendiran, Thabo
    Rotzinger, David
    Fournier, Stephane
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2021, 14 (05) : 894 - 901
  • [4] Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation
    David Meier
    Arnaud Depierre
    Antoine Topolsky
    Christan Roguelov
    Marion Dupré
    Vladimir Rubimbura
    Eric Eeckhout
    Salah Dine Qanadli
    Olivier Muller
    Thabo Mahendiran
    David Rotzinger
    Stephane Fournier
    Journal of Cardiovascular Translational Research, 2021, 14 : 894 - 901
  • [5] Transcatheter Aortic-Valve Implantation for Aortic Stenosis
    Newman, Jonathan
    Shimbo, Daichi
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (02): : 180 - 180
  • [6] Performance of quantitative flow ratio in patients with aortic stenosis undergoing transcatheter aortic valve implantation
    Sejr-Hansen, Martin
    Christiansen, Evald Hoj
    Ahmad, Yousif
    Vendrik, Jeroen
    Westra, Jelmer
    Holm, Niels R.
    Thim, Troels
    Seligman, Henry
    Hall, Kerry
    Sen, Sayan
    Terkelsen, Christian Juhl
    Eftekhari, Ashkan
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (01) : 68 - 73
  • [7] Coronary Artery Disease in Patients with Aortic Stenosis and Transcatheter Aortic Valve Implantation: Implications for Management
    de Azevedo Filho, Antonio F. B.
    Accorsi, Tarso A. D.
    Ribeiro, Henrique B.
    EUROPEAN CARDIOLOGY REVIEW, 2021, 16
  • [8] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Opolski, Maksymilian P.
    Kim, Won-Keun
    Liebetrau, Christoph
    Walther, Claudia
    Blumenstein, Johannes
    Gaede, Luise
    Kempfert, Joerg
    Van Linden, Arnaud
    Walther, Thomas
    Hamm, Christian W.
    Moellmann, Helge
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (06) : 471 - 480
  • [9] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Opolski, M. P.
    Kim, W. K.
    Walther, C.
    Walther, T.
    Blumenstein, J.
    Liebetrau, C.
    Gaede, L.
    Kempfert, J.
    Hamm, C. W.
    Moellmann, H.
    EUROPEAN HEART JOURNAL, 2014, 35 : 715 - 716
  • [10] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Maksymilian P. Opolski
    Won-Keun Kim
    Christoph Liebetrau
    Claudia Walther
    Johannes Blumenstein
    Luise Gaede
    Jörg Kempfert
    Arnaud Van Linden
    Thomas Walther
    Christian W. Hamm
    Helge Möllmann
    Clinical Research in Cardiology, 2015, 104 : 471 - 480