Mortality after treatment of intracranial aneurysms with the Pipeline Embolization Device

被引:7
|
作者
Kang, Huibin [1 ]
Luo, Bin [1 ]
Liu, Jianmin [2 ]
Zhang, Hongqi [3 ]
Li, Tianxiao [4 ]
Song, Donglei [5 ]
Zhao, Yuanli [6 ]
Guan, Sheng [7 ]
Maimaitili, Aisha [8 ]
Wang, Yunyan [9 ]
Feng, Wenfeng [10 ]
Wang, Yang [11 ]
Wan, Jieqing [12 ]
Mao, Guohua [13 ]
Shi, Huaizhang [14 ]
Wang, Kun [1 ]
Yang, Xinjian [1 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, 119 South Fourth Ring West Rd, Beijing 100050, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Shanghai, Peoples R China
[3] Capital Med Univ, Xuanwu Hosp, Beijing, Peoples R China
[4] Zhengzhou Univ Peoples Hosp, Zhengzhou, Peoples R China
[5] Shanghai Donglei Brain Hosp, Shanghai, Peoples R China
[6] Peking Univ Int Hosp, Beijing, Peoples R China
[7] Zhengzhou Univ, Affiliated Hosp 1, Zhengzhou, Henan, Peoples R China
[8] Xinjiang Med Univ, Affiliated Hosp 1, Urumqi, Xinjiang, Peoples R China
[9] Shandong Univ, Qilu Hosp, Jinan, Peoples R China
[10] Southern Med Univ, Nanfang Hosp, Guangzhou, Guangdong, Peoples R China
[11] Nanchang Univ, Affiliated Hosp 1, Nanchang, Jiangxi, Peoples R China
[12] Shanghai Jiao Tong Univ, Sch Med, Renji Hosp, Shanghai, Peoples R China
[13] Nanchang Univ, Affiliated Hosp 2, Nanchang, Jiangxi, Peoples R China
[14] Harbin Med Univ, Affiliated Hosp 1, Harbin, Peoples R China
基金
中国国家自然科学基金;
关键词
aneurysm; complication; stroke; flow diverter; CEREBRAL ANEURYSMS; FLOW DIVERSION; OUTCOMES; SAFETY;
D O I
10.1136/neurintsurg-2020-017002
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background The Pipeline Embolization Device (PED) is reported to be a safe treatment tool for aneurysms. However, mortality occurs in a few cases, and this has not been clearly studied. We conducted a multicenter study to retrospectively evaluate the causes of, and risk factors for, mortality in patients with intracranial aneurysms treated with the PED. Methods We retrospectively reviewed the prospectively maintained databases of patients with intracranial aneurysms treated by PED placement at 14 academic institutions from 2014 to 2019. Patients' data, including clinical and radiographic information, were analyzed with an emphasis on mortality-related complications. Results A total of 1171 consecutive patients underwent 1319 PED procedures to treat 1322 intracranial aneurysms. The mortality rate was 1.5% (17/1171), and in 1.3% of the patients (15/1171), deaths were caused by delayed aneurysmal rupture, distal intraparenchymal hemorrhage, and neurological compression symptoms associated with PED procedures. Multivariate analysis showed that previous treatment (OR, 12.657; 95% CI, 3.189 to 50.227; P<0.0001), aneurysm size >= 10 mm (OR, 4.704; 95% CI, 1.297 to 17.068; P=0.019), aneurysm location (basilar artery) (OR, 10.734; 95% CI, 2.730 to 42.207; P=0.001), and current subarachnoid hemorrhage (OR, 4.505; 95% CI, 0.991 to 20.474; P=0.051) were associated with neurological complications resulting in mortality. Conclusions Delayed aneurysm rupture, distal intraparenchymal hemorrhage, and neurological compression were the main causes of mortality in patients with intracranial aneurysms treated with the PED. Large basilar aneurysms are associated with an increased risk of postoperative death and require increased attention and caution.
引用
收藏
页码:46 / +
页数:6
相关论文
共 50 条
  • [1] The Pipeline embolization device for treatment of intracranial aneurysms
    Eller, Jorge L.
    Dumont, Travis M.
    Sorkin, Grant C.
    Mokin, Maxim
    Levy, Elad I.
    Snyder, Kenneth V.
    Hopkins, L. Nelson
    Siddiqui, Adnan H.
    EXPERT REVIEW OF MEDICAL DEVICES, 2014, 11 (02) : 137 - 150
  • [2] Treatment of Ruptured Intracranial Aneurysms With the Pipeline Embolization Device
    Chalouhi, Nohra
    Zanaty, Mario
    Whiting, Alex
    Tjoumakaris, Stavropoula
    Hasan, David
    Ajiboye, Norman
    Hann, Shannon
    Rosenwasser, Robert H.
    Jabbour, Pascal
    NEUROSURGERY, 2015, 76 (02) : 165 - 172
  • [3] The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
    Nelson, P. K.
    Lylyk, P.
    Szikora, I.
    Wetzel, S. G.
    Wanke, I.
    Fiorella, D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (12) : S43 - S49
  • [4] The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
    Nelson, P. K.
    Lylyk, P.
    Szikora, I.
    Wetzel, S. G.
    Wanke, I.
    Fiorella, D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 34 - 40
  • [5] Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device
    Chalouhi, Nohra
    Chitale, Rohan
    Starke, Robert M.
    Jabbour, Pascal
    Tjoumakaris, Stavropoula
    Dumont, Aaron S.
    Rosenwasser, Robert H.
    Gonzalez, L. Fernando
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (01) : 19 - 23
  • [6] Treatment of unruptured intracranial aneurysms with the pipeline embolization device
    Murthy, Santosh B.
    Shah, Shreyansh
    Rao, Chethan P. Venkatasubba
    Bershad, Eric M.
    Suarez, Jose I.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (01) : 6 - 11
  • [7] Predictors of Clinical Outcome After Treatment of Intracranial Aneurysms with the Pipeline Embolization Device
    Griffin, Andrew
    Reese, Vanessa
    Huseyinoglu, Zeynep
    Niedzwiecki, Donna
    Yang, Lexie
    Cutler, Andrew
    Gonzalez, L. Fernando
    Zomorodi, Ali
    Smith, Tony
    Hauck, Erik F.
    WORLD NEUROSURGERY, 2019, 130 : E666 - E671
  • [8] Pipeline Embolization Device for the Treatment of Unruptured Intracranial Dissecting Aneurysms
    Chen, Jigang
    Tao, Mushun
    Han, Jiangli
    Feng, Xin
    Peng, Fei
    Tong, Xin
    Niu, Hao
    Ma, Ning
    Liu, Aihua
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [9] The Role of the Pipeline Embolization Device for the Treatment of Dissecting Intracranial Aneurysms
    de Barros Faria, M.
    Nella Castro, R.
    Lundquist, J.
    Scrivano, E.
    Ceratto, R.
    Ferrario, A.
    Lylyk, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) : 2192 - 2195
  • [10] A Single Pipeline Embolization Device is Sufficient for Treatment of Intracranial Aneurysms
    Chalouhi, N.
    Tjoumakaris, S.
    Phillips, J. L. H.
    Starke, R. M.
    Hasan, D.
    Wu, C.
    Zanaty, M.
    Kung, D.
    Gonzalez, L. F.
    Rosenwasser, R.
    Jabbour, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (08) : 1562 - 1566