Rapid lactate oxidase-based assay for lactate content in milk to ascertain its hygienic quality

被引:1
|
作者
Kumar, Brajesh [1 ]
Sharma, Rajan [1 ]
Thakur, Rahul [1 ]
Barui, Amit Kumar [1 ]
Rajput, Yudhishthir S. [2 ]
Mann, Bimlesh [1 ]
机构
[1] Natl Dairy Res Inst, Div Dairy Chem, Karnal 132001, Haryana, India
[2] Natl Dairy Res Inst, Anim Biochem Div, Karnal 132001, Haryana, India
关键词
Milk; L-Lactate; Lactate oxidase; Neutraliser; Milk hygiene; L-LACTIC ACID; COW-MILK; BIOSENSOR; GLUCOSE; STRIP; RAW;
D O I
10.1111/1471-0307.12285
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A rapid method for qualitative and quantitative assaying of L-lactate in milk is described. The method is based on oxidation of lactate by lactate oxidase with the simultaneous formation of H2O2 which subsequently oxidises 2, 4, 6-tribromo 3-hydroxy benzoic acid (TBHBA) in the presence of peroxidase. Oxidised TBHBA then reacts with 4-amino antipyrine to obtain magenta colour (lambda(max) = 523 nm). In the qualitative assay, colour change becomes visible in raw milk samples spiked with 300 mg lactate/L. The absorbance increases linearly up to 1000 mg/L. The method can be used for rapid assessment of the hygienic quality of milk.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 17 条
  • [1] Rapid lactate oxidase-based assay for lactate content in milk to ascertain its hygienic quality (vol 69, pg 460, 2017)
    Kumar, Brajesh
    Sharma, Rajan
    Thakur, Rahul
    Barui, Amit Kumar
    Rajput, Yudhishthir S.
    Mann, Bimlesh
    INTERNATIONAL JOURNAL OF DAIRY TECHNOLOGY, 2017, 70 (03) : 457 - 457
  • [2] Clinical applications of L-lactate oxidase-based biosensor
    Xing, K
    Liu, YF
    Wang, L
    Qiao, H
    Lizhi, Y
    INTERNATIONAL CONFERENCE ON SENSOR TECHNOLOGY (ISTC 2001), PROCEEDINGS, 2001, 4414 : 141 - 144
  • [3] Influence of macroporous gold support and its functionalization on lactate oxidase-based biosensors response
    Gamero, M.
    Sosna, M.
    Pariente, F.
    Lorenzo, E.
    Bartlett, P. N.
    Alonso, C.
    TALANTA, 2012, 94 : 328 - 334
  • [4] Dual range lactate oxidase-based screen printed amperometric biosensor for analysis of lactate in diversified samples
    Cunha-Silva, Hugo
    Julia Arcos-Martinez, M.
    TALANTA, 2018, 188 : 779 - 787
  • [5] Nanostructured rough gold electrodes for the development of lactate oxidase-based biosensors
    Gamero, M.
    Pariente, F.
    Lorenzo, E.
    Alonso, C.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (09): : 2038 - 2044
  • [6] Prussian Blue- and lactate oxidase-based amperometric biosensor for lactic acid
    Garjonyte, R
    Yigzaw, Y
    Meskys, R
    Malinauskas, A
    Gorton, L
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) : 33 - 38
  • [7] CATALYTIC ASSAY OF L-LACTATE OR PYRUVATE WITH AN ENZYME ELECTRODE BASED ON IMMOBILIZED LACTATE OXIDASE AND LACTATE-DEHYDROGENASE
    MIZUTANI, F
    SHIMURA, Y
    TSUDA, K
    CHEMISTRY LETTERS, 1984, (02) : 199 - 202
  • [8] Recent progress in lactate oxidase-based drug delivery systems for enhanced cancer therapy
    Li, Lu
    Yue, Tian
    Feng, Jie
    Zhang, Yujun
    Hou, Jun
    Wang, Yi
    NANOSCALE, 2024, 16 (18) : 8739 - 8758
  • [9] Mill Scale-Derived Magnetite Nanoparticles: A Novel Substrate for Lactate Oxidase-Based Biosensors
    Khosravi, Hamid
    Carreras-Gallo, Oscar
    Casals-Terre, Jasmina
    BIOSENSORS-BASEL, 2023, 13 (11):
  • [10] AMPEROMETRIC L-LACTATE-SENSING ELECTRODE BASED ON A POLYION COMPLEX LAYER CONTAINING LACTATE OXIDASE - APPLICATION TO SERUM AND MILK SAMPLES
    MIZUTANI, F
    YABUKI, S
    HIRATA, Y
    ANALYTICA CHIMICA ACTA, 1995, 314 (03) : 233 - 239