A Comparison of the Effects of Intraosseous and Intravenous 5% Albumin on Infusion Time and Hemodynamic Measures in a Swine Model of Hemorrhagic Shock

被引:8
|
作者
Muir, Stacy L. [1 ]
Sheppard, Lance B. [1 ]
Maika-Wilson, Anne [1 ]
Burgert, James M. [1 ,2 ]
Garcia-Blanco, Jose [2 ]
Johnson, Arthur D. [1 ,2 ]
Coyner, Jennifer L. [1 ]
机构
[1] Northeastern Univ, US Army Med Dept Ctr & Sch, US Army Grad Program Anesthesia Nursing, Ft Sam Houston, TX USA
[2] Geneva Fdn, Tacoma, WA USA
关键词
albumin; hemorrhagic shock; infusion time; intraosseous; resuscitation; NATURAL COLLOID RESUSCITATION; FREEZE-DRIED PLASMA; DILUTIONAL COAGULOPATHY; INCREASING HEMORRHAGE; VASCULAR ACCESS; GUIDELINES; INJURY; BLOOD;
D O I
10.1017/S1049023X16000509
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Obtaining intravenous (IV) access in patients in hemorrhagic shock is often difficult and prolonged. Failed IV attempts delay life-saving treatment. Intraosseous (IO) access may often be obtained faster than IV access. Albumin (5%) is an option for prehospital volume expansion because of the absence of interference with coagulation and platelet function. Hypothesis/Problem There are limited data comparing the performance of IO and IV administered 5% albumin. The aims of this study were to compare the effects of tibial IO (TIO) and IV administration of 500 mL of 5% albumin on infusion time and hemodynamic measurements of heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and stroke volume (SV) in a swine model of hemorrhagic shock. Methods Sixteen male swine were divided into two groups: TIO and IV. All subjects were anesthetized and a Class III hemorrhage was achieved by exsanguination of 31% of estimated blood volume (EBV) from a femoral artery catheter. Following exsanguination, 500 mL of 5% albumin was administered under pressurized infusion (300 mmHg) by the TIO or IV route and infusion time was recorded. Hemodynamic measurements of HR, MAP, CO, and SV were collected before and after exsanguination and every 20 seconds for 180 seconds during 5% albumin infusion. Results An independent t-test determined that IV 5% albumin infusion was significantly faster compared to IO (P=.01). Mean infusion time for TIO was seven minutes 35 seconds (SD=two minutes 44 seconds) compared to four minutes 32 seconds (SD=one minute 08 seconds) in the IV group. Multivariate Analysis of Variance was performed on hemodynamic data collected during the 5% albumin infusion. Analyses indicated there were no significant differences between the TIO and IV groups relative to MAP, CO, HR, or SV (P>.05). Conclusion While significantly longer to infuse 5% albumin by the TIO route, the longer TIO infusion time may be negated as IO devices can be placed more quickly compared to repeated IV attempts. The lack of significant difference between the TIO and IV routes relative to hemodynamic measures indicate the TIO route is a viable route for the infusion of 5% albumin in a swine model of Class III hemorrhage.
引用
收藏
页码:436 / 442
页数:7
相关论文
共 50 条
  • [1] Safety of Pressurized Intraosseous Blood Infusion Strategies in a Swine Model of Hemorrhagic Shock
    Auten, Jonathan D.
    McEvoy, Christian S.
    Roszko, Paul J.
    Polk, Travis M.
    Kachur, Ryan E.
    Kemp, Jean D.
    Natarajan, Ramesh
    Zarow, Greg J.
    JOURNAL OF SURGICAL RESEARCH, 2020, 246 : 190 - 199
  • [2] COMPARISON OF INTRAOSSEOUS, CENTRAL, AND PERIPHERAL ROUTES OF CRYSTALLOID INFUSION FOR RESUSCITATION OF HEMORRHAGIC-SHOCK IN A SWINE MODEL
    NEUFELD, JDG
    MARX, JA
    MOORE, EE
    LIGHT, AI
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (03): : 422 - 428
  • [3] Effects of Intraosseous Erythropoietin during Hemorrhagic Shock in Swine
    Borovnik-Lesjak, Vesna
    Whitehouse, Kasen
    Baetiong, Alvin
    Miao, Yang
    Currie, Brian M.
    Velmurugan, Sathya
    Radhakrishnan, Jeejabai
    Gazmuri, Raul J.
    PLOS ONE, 2014, 9 (11):
  • [4] Hypertonic saline: Intraosseous infusion causes myonecrosis in a dehydrated swine model of uncontrolled hemorrhagic shock
    Alam, HB
    Punzalan, CM
    Koustova, E
    Bowyer, MW
    Rhee, P
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 52 (01): : 18 - 25
  • [5] A Comparison of Intraosseous Pressure Transfusion Strategies in a High Bone Density In Vivo Swine Model of Hemorrhagic Shock
    Stein, M.
    Auten, J.
    Reilly, E.
    Gehrz, J.
    Morrison, T.
    Beville, E.
    Powell, J.
    Fry, P.
    Burgess, B.
    Bianci, W.
    ANNALS OF EMERGENCY MEDICINE, 2023, 82 (04) : S105 - S105
  • [6] TREATMENT OF HEMORRHAGIC-SHOCK WITH INTRAOSSEOUS OR INTRAVENOUS-INFUSION OF HYPERTONIC SALINE DEXTRAN SOLUTION
    CHAVEZNEGRETE, A
    CRUZ, SM
    MUNARI, AF
    PERCHES, A
    ARGUERO, R
    EUROPEAN SURGICAL RESEARCH, 1991, 23 (02) : 123 - 129
  • [7] HEMODYNAMIC EFFECTS OF BLOOD PRESSURE-TARGETED STEPWISE RESUSCITATION IN SWINE HEMORRHAGIC SHOCK MODEL
    Hwang, J.
    Lee, J.
    Kim, K.
    Jo, Y.
    Lee, J.
    Kim, J.
    Chung, H.
    Lee, M.
    Yu, M.
    SHOCK, 2015, 43 (06): : 21 - 22
  • [8] The effects of hemorrhagic shock secondary to hepatectomy in a swine model
    Mylonas, Anastasios I.
    Orfanos, Nikolaos F.
    Karmaniolou, Iosifina I.
    Lolis, Evangelos D.
    Stergiou, Eirini P.
    Papalois, Apostolos E.
    Nomikos, Tzortzis N.
    Kondi-Pafiti, Agathi I.
    Smyrniotis, Vasileios E.
    Arkadopoulos, Nikolaos F.
    JOURNAL OF SURGICAL RESEARCH, 2015, 195 (01) : 228 - 234
  • [9] Effects of Erythropoietin during Hemorrhagic Shock in a Swine Model
    Whitehouse, Kasen
    Lesjak, Vesna Borovnik
    Miao, Yang
    Baetiong, Alvin
    Velmurugan, Sathya
    Currie, Brian
    Radhakrishnan, Jeejabal
    Gazmuri, Raul J.
    CIRCULATION, 2012, 126 (21)
  • [10] Intraosseous Pressure infusion Comparison Using a Rapid Infusion Device and a Pressure Bag In a Swine Model
    Lairet, J. R.
    Bebarta, V
    Lairet, K.
    Kacprowicz, R.
    Johnson, R.
    Pitotti, R.
    Bolleter, S.
    Cowart, J.
    Bush, A.
    ANNALS OF EMERGENCY MEDICINE, 2010, 56 (03) : S26 - S27