False increase of cardiac troponin I with heterophilic antibodies

被引:0
|
作者
Fitzmaurice, TF
Brown, C
Rifai, N
Wu, AHB
Yeo, KTJ
机构
[1] Dartmouth Coll, Hitchcock Med Ctr, Lebanon, NH 03756 USA
[2] Dartmouth Coll, Sch Med, Lebanon, NH 03756 USA
[3] Childrens Hosp, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Boston, MA 02115 USA
[5] Hartford Hosp, Clin Chem Lab, Hartford, CT 06102 USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:2212 / 2214
页数:3
相关论文
共 50 条
  • [1] False-positive cardiac troponin T due to assay interference with heterophilic antibodies
    Shayanfar, Noushin
    Bestmann, Lukas
    Schulthess, Georg
    Hersberger, Martin
    [J]. SWISS MEDICAL WEEKLY, 2008, 138 (31-32) : 470 - 470
  • [2] Performance of the enhanced Abbott AxSYM Cardiac Troponin I reagent in patients with heterophilic antibodies
    Yeo, KTJ
    Storm, CA
    Li, Y
    Jayne, JE
    Brough, T
    Quinn-Hall, KS
    Fitzmaurice, TF
    [J]. CLINICA CHIMICA ACTA, 2000, 292 (1-2) : 13 - 23
  • [3] Attention should be paid to false-positive results due to heterophilic antibodies interfering with Abbott high-sensitivity cardiac troponin I assay
    Liu, Weiping
    Long, Xia
    Chen, Lulu
    Yang, Kailan
    [J]. JOURNAL OF LABORATORY MEDICINE, 2024, 48 (03) : 137 - 140
  • [4] Determination of the frequency and characterization of heterophilic antibodies that produce interference in a common immunoassay for cardiac Troponin I.
    Laterza, O
    Hock, KG
    Jurga, PA
    Pierson-Perry, J
    Bauer, RS
    Scott, MG
    [J]. CLINICAL CHEMISTRY, 2001, 47 (06) : A44 - A44
  • [5] Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies
    Kim, WJ
    Laterza, OF
    Hock, KG
    Pierson-Perry, JF
    Kaminski, DM
    Mesguich, M
    Braconnier, F
    Zimmermann, R
    Zaninotto, M
    Plebani, M
    Hanna, A
    Cembrowski, GS
    Scott, MG
    [J]. CLINICAL CHEMISTRY, 2002, 48 (07) : 1028 - 1034
  • [6] Interference of heterophilic antibodies in cardiac troponin I assay can be eliminated by pretreating serum with mouse immunoglobulin.
    Saffer, H
    Dasgupta, A
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2001, 116 (02) : 286 - 286
  • [7] Grossly Elevated False-Positive High-Sensitivity Troponin I Due to Heterophilic Antimouse IgG1 Antibodies
    Lewis, John G.
    Connolly, Alison J. L.
    Ploeg, Hank
    Phillips, Ian J.
    King, Richard I.
    Elder, Peter A.
    Florkowski, Christopher M.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2020, 5 (04): : 815 - 817
  • [8] False positive pregnancy test through heterophilic antibodies
    Ludwig, M
    Weger, B
    Schulte, HM
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 2004, 64 (04) : 411 - 414
  • [9] A case of false positive cardiac troponin I in CANOMAD syndrome
    Ben Lassoued, A.
    Fromonot, J.
    Marlinge, M.
    Basset, N.
    Chefrour, M.
    Vairo, D.
    Couillaud, J.
    Lopez, L.
    Cuisset, T.
    Boucraut, J.
    Delmont, E.
    Attarian, S.
    Guieu, R.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 359 - 360
  • [10] Cardiac troponin I does not increase after cardioversion
    Bonnefoy, E
    Chevalier, P
    Kirkorian, G
    Guidolet, J
    Marchand, A
    Touboul, P
    [J]. CHEST, 1997, 111 (01) : 15 - 18