Evaluation of an isothermal signal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus from patient-screening swabs

被引:20
|
作者
Levi, K
Bailey, C
Bennett, A
Marsh, P
Cardy, DLN
Towner, KJ [1 ]
机构
[1] Univ Nottingham Hosp, Queens Med Ctr, Publ Hlth Lab, Mol Diagnost & Typing Unit, Nottingham NG7 2UH, England
[2] Cytocell Ltd, Oxford OX17 3SN, England
关键词
D O I
10.1128/JCM.41.7.3187-3191.2003
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A new molecular assay (CytAMP) utilizing isothermal signal-mediated amplification of RNA was evaluated for rapid detection of methicillin (oxacillin)-resistant Staphylococcus aureus (MRSA). The assay targeted the coa (coagulase) and mecA genes, thereby simultaneously identifying S. aureus and methicillin (oxacillin) resistance. Results were obtained in approximately 3.5 h as a color signal in 96-well microliter plates. The detection limit was between 2 x 10(5) and 10(6) CFU/assay, equivalent to 4 x 10(6) to 2 x 10(7) CFU/ml in an overnight broth. This level of growth was obtained with an initial inoculum of 10 to 50 CFU. The CytAMP assay and a mecA-femB PCR assay both detected 113 MRSA strains among 396 clinical isolates of bacteria (CytAMP sensitivity and specificity were both 100% relative to those of PCR). Conventional culture detected 109 MRSA strains, but with 19 false-positive and 23 false-negative results relative to both molecular methods. Discrepancies were also observed for 100 enrichment broths containing MRSA screening swabs, with 11 broths culture negative but PCR positive. CytAMP and PCR were more in agreement, but six broths were CytAMP negative and PCR positive. Five of these contained 10(2) to 10(5) CFU/assay (below the CytAMP detection limit of 2 x 10(5) CFU/assay), and the sixth contained 106 CFU/assay. Overall, culture and CytAMP had similar sensitivities and specificities relative to those of PCR, but the CytAMP assay enabled swabs to be analyzed as a batch following overnight incubation in enrichment broth, with results reported before 12 noon the next day.
引用
收藏
页码:3187 / 3191
页数:5
相关论文
共 50 条
  • [1] The application of the loop-mediated isothermal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus
    Khosravi, A. D.
    Khoshnood, S.
    Montazeri, E. Abbasi
    Jomehzadeh, N.
    Moradi, M.
    Shahi, F.
    NEW MICROBES AND NEW INFECTIONS, 2022, 45
  • [2] A PCR method for the identification of methicillin-resistant Staphylococcus aureus (MRSA) from screening swabs
    Hope, WW
    Morton, AP
    Looke, DFM
    Schooneveldt, JM
    Nimmo, GR
    PATHOLOGY, 2004, 36 (03) : 265 - 268
  • [3] SCREENING METHOD FOR RAPID DETECTION OF METHICILLIN-RESISTANT (HETERORESISTANT) STAPHYLOCOCCUS-AUREUS
    HANSEN, SL
    POPE, WA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (05) : 886 - 887
  • [4] Rapid PCR-based identification of methicillin-resistant Staphylococcus aureus from screening swabs
    Jonas, D
    Speck, M
    Daschner, FD
    Grundmann, H
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (05) : 1821 - 1823
  • [5] Clinical Application of Loop-Mediated Isothermal Amplification in the Rapid Detection of Methicillin-Resistant Staphylococcus aureus
    Li, Cai-Yan
    Huang, Wen-Feng
    Cai, E.
    Wang, Qun-Li
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2015, 9 : 31 - 35
  • [6] Comparison of three chromogenic media for rapid detection of methicillin-resistant Staphylococcus aureus from screening swabs in hospitalised patients
    Nonhoff, C.
    Denis, O.
    Brenner, A.
    Buidin, P.
    Thiroux, C.
    Struelens, M.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S451 - S451
  • [7] Evaluation of Different Screening Methodologies for the Detection of Methicillin-Resistant Staphylococcus aureus from Environmental Surfaces: Swabs, Gauzes, and Polywipes
    Aires-de-Sousa, Marta
    Rodrigues, Suzilaine
    Conceicao, Teresa
    de Lencastre, Herminia
    MICROBIAL DRUG RESISTANCE, 2018, 24 (05) : 585 - 589
  • [8] Rapid detection of methicillin-resistant Staphylococcus aureus and SCCmec types from nasal swabs by multiplex PCR
    Cavalcante, Fernanda Sampaio
    Abad, Eliane de Dios
    Fonseca Guimaraes, Ana Carolina
    Barbosa, Simone Saintive
    Ribeiro, Marcia
    Ferreira, Dennis de Carvalho
    Netto dos Santos, Katia Regina
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2016, 10 (02): : 195 - 198
  • [10] Evaluation of Molecular Assays for Rapid Detection of Methicillin-Resistant Staphylococcus aureus
    Malhotra-Kumar, Surbhi
    Van Heirstraeten, Liesbet
    Lee, Andie
    Abrahantes, Jose Cortinas
    Lammens, Christine
    Vanhommerig, Evelyn
    Molenberghs, Geert
    Aerts, Marc
    Harbarth, Stephan
    Goossens, Herman
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (12) : 4598 - 4601