Structural control of a prototype building using an MR damper

被引:0
|
作者
Lau, YK [1 ]
Wong, KY [1 ]
Liao, WH [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Automat & Comp Aided Engn, Smart Mat & Struct Lab, Shatin, Hong Kong, Peoples R China
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Buildings provide the physical foundation for a society's wealth and quality of life. Vibration problems of buildings mainly arise from seismic loadings due to earthquakes and strong winds due to typhoons. Effective vibration control of buildings is desired so that the living safety and comfort will be improved. In this paper, a double-ended magnetorheological (MR) damper for a prototype building is designed and manufactured. The developed MR damper is tested and the behavior of the MR damper is characterized. A dynamic phenomenological model is adopted to describe the MR damper behavior. Then the MR damper is integrated with a prototype building to develop a structural control system. Multi-voltage control is implemented to show the feasibility of vibration control of a building using a controlled MR damper.
引用
收藏
页码:319 / 328
页数:10
相关论文
共 50 条
  • [1] Application of MR damper in structural control using ANFIS method
    Gu, Zhi Q.
    Oyadiji, S. Olutunde
    [J]. COMPUTERS & STRUCTURES, 2008, 86 (3-5) : 427 - 436
  • [2] Optimal static output feedback control of a building using an MR damper
    Purohit, Sharadkumar
    Chandiramani, Naresh K.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2011, 18 (08): : 852 - 868
  • [3] Seismic response control of adjacent building by using hybrid control algorithm of MR damper
    Department of Architectural Engineering, Seoil University, Seoul, Korea, Republic of
    不详
    [J]. Procedia Eng., (1013-1020):
  • [4] Seismic Response Control of Adjacent Building by using Hybrid Control Algorithm of MR Damper
    Kim, G. C.
    Kang, J. W.
    [J]. PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14 : 1013 - 1020
  • [5] Tall building vibration control using a TM-MR damper assembly
    Zemp, Rene
    de la Llera, Juan C.
    Almazan, Jose L.
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (03): : 339 - 354
  • [6] SEISMIC RESPONSE CONTROL OF A BUILDING USING MR DAMPER WITH OPTIMAL STATIC OUTPUT FEEDBACK
    Purohit, Sharadkumar
    Chandiramani, Naresh K.
    [J]. PROCEEDINGS OF THE 17TH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, 2010,
  • [7] Experiment investigation of structural seismic control with MR damper
    State Key Lab of Costal and Offshore Engineering, Dalian University of Technology, Dalian 116024, China
    [J]. Xitong Fangzhen Xuebao, 2006, 5 (1343-1346):
  • [8] Intelligent Control method of Structural Vibration Based on MR Damper
    Liu, Jianjun
    Xia, Kaiquan
    Zhu, Caixia
    [J]. 2009 SECOND INTERNATIONAL CONFERENCE ON FUTURE INFORMATION TECHNOLOGY AND MANAGEMENT ENGINEERING, FITME 2009, 2009, : 320 - +
  • [9] Semi-Active Control of a Benchmark Building using Neuro-Inverse Dynamics of MR Damper
    Vadtala, Irfan H.
    Soni, Devesh P.
    Panchal, Dolarray. G.
    [J]. CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 45 - 54
  • [10] An experimental study of semiactive modal neuro-control scheme using MR damper for building structure
    Lee, Heon-Jae
    Jung, Hyung-Jo
    Cho, Sang-Won
    Lee, In-Won
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2008, 19 (09) : 1005 - 1015