Time-domain fluorescence molecular tomography based on experimental data

被引:0
|
作者
Zhang, Limin [1 ]
Li, Jiao [1 ]
Gao, Feng [1 ]
He, Huiyuan [1 ]
Zhao, Huijuan [1 ]
机构
[1] Tianjin Univ, Coll Precis Instrument & Optoeletron Engn, Tianjin 300072, Peoples R China
关键词
Fluorescence molecular tomography; Time-domain; Image reconstruction algorithm; Generalized pulse spectrum technique; DIFFUSE OPTICAL TOMOGRAPHY; RECONSTRUCTION; ALGORITHM; SCHEME; MEDIA;
D O I
10.1117/12.807445
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a 3D scheme for time-domain fluorescence molecular tomography within the normalized Born-ratio formulation. A finite element method solution to the Laplace transformed time-domain coupled diffusion equations is employed as the forward model, and the resultant linear inversions at two distinct transform-factors are solved with an algebraic reconstruction technique to separate fluorescent yield and lifetime images. By use of a multichannel time-correlation single photon counting system, we experimentally validate that the proposed scheme can achieve simultaneous reconstruction of the fluorescent yield and lifetime distributions with a reasonable accuracy.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Linear scheme for time-domain fluorescence molecular tomography
    高峰
    刘维
    赵会娟
    [J]. Chinese Optics Letters, 2006, (10) : 595 - 597
  • [2] A linear GPST-based scheme for time-domain fluorescence molecular tomography
    Gao, Feng
    Xue, Yuan
    Zhao, Huijuan
    Tanikawa, Yukari
    Yamada, Yukio
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [3] A linear, featured-data scheme for image reconstruction in time-domain fluorescence molecular tomography
    Gao, Feng
    Zhao, Huijuan
    Tanikawa, Yukari
    Yamada, Yukio
    [J]. OPTICS EXPRESS, 2006, 14 (16): : 7109 - 7124
  • [4] Direct reconstruction method for time-domain fluorescence molecular lifetime tomography
    Cai, Chuangjian
    Zhang, Lin
    Zhang, Jiulou
    Bai, Jing
    Luo, Jianwen
    [J]. OPTICS LETTERS, 2015, 40 (17) : 4038 - 4041
  • [5] Mesh-based Monte Carlo method in time-domain widefield fluorescence molecular tomography
    Chen, Jin
    Fang, Qianqian
    Intes, Xavier
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)
  • [6] Experimental validation for time-domain fluorescence diffuse optical tomography of linear scheme
    高峰
    张丽敏
    李娇
    赵会娟
    [J]. Chinese Optics Letters, 2008, 6 (12) : 889 - 892
  • [7] Experimental validation for time-domain fluorescence diffuse optical tomography of linear scheme
    Gao, Feng
    Zhang, Limin
    Li, Jiao
    Zhao, Huijuan
    [J]. CHINESE OPTICS LETTERS, 2008, 6 (12) : 889 - 892
  • [8] Self-guided reconstruction for time-domain fluorescence molecular lifetime tomography
    Cai, Chuangjian
    Cai, Wenjuan
    Cheng, Jiaju
    Yang, Yuxuan
    Luo, Jianwen
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (12)
  • [9] Depth-recognizable time-domain fluorescence molecular tomography in reflective geometry
    Cheng, Jiaju
    Zhang, Peng
    Cai, Chuangjian
    Gao, Yang
    Liu, Jie
    Hui, Hui
    Tian, Jie
    Luo, Jianwen
    [J]. BIOMEDICAL OPTICS EXPRESS, 2021, 12 (07): : 3806 - 3818
  • [10] In-vivo experimental validation for a featured-data time-domain diffuse fluorescence tomography based on the radiative transfer equation
    Zhang, Yan
    Zhang, Limin
    Jin, Meng
    Zhao, Huijuan
    Gao, Feng
    Li, Jiao
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XI, 2015, 9319