Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants

被引:44
|
作者
Rohlmann, A [1 ]
Zander, T [1 ]
Bergmann, G [1 ]
机构
[1] Charite Univ Med Berlin, Biomech Lab, D-12203 Berlin, Germany
关键词
biomechanics; finite element method; internal fixation device; lumbar spine; MACS system;
D O I
10.1007/s00586-004-0784-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Posteriorly and anteriorly fixed implants for stabilizing unstable spines are available on the market. Differences in the biomechanical behavior of these implant types are not yet fully clear. They were investigated using three-dimensional nonlinear finite element models of the lumbar spine in an intact state, with an anteriorly fixed MACS-TL implant and with posteriorly fixed internal fixators. The bisegmental implants spanned the L3 vertebra, and bone grafts were used with both implant types to replace parts of the two bridged discs. The computer models were loaded with partial body weight and muscle forces simulating standing, flexion, extension and axial rotation. Both implant types have reduced intersegmental rotation for flexion, extension, and axial rotation in the bridged region. The reduction is more pronounced for the MACS-TL implant. The implant type has only a minor effect on intradiscal pressure. Maximum von Mises stresses in the vertebrae are lower for flexion and extension with the MACS-TL implant than with the internal fixator. Very high stresses are predicted for flexion after insertion of internal fixators. For standing and torsion, maximum stresses differ only negligibly between the two implant types. In the period immediately after surgery, patients with osteoporotic vertebrae and who are treated with an internal spinal fixation device should therefore avoid excessive flexion. This study adds new information about the mechanical behavior of the lumbar spine after insertion of posterior and anterior spine-stabilizing implants. This information improves our biomechanical understanding of the spine.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 50 条
  • [1] Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants
    Antonius Rohlmann
    T. Zander
    G. Bergmann
    [J]. European Spine Journal, 2005, 14 : 445 - 453
  • [2] Spine-stabilizing muscles in runners
    Schmid, T
    Mederer, A
    Weishaupt, P
    Möckel, F
    Prochnow, T
    [J]. SPORTVERLETZUNG-SPORTSCHADEN, 2002, 16 (02) : 59 - 63
  • [3] A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine
    Koh, YD
    Lim, TH
    You, JW
    Eck, J
    An, HS
    [J]. SPINE, 2001, 26 (01) : 15 - 21
  • [4] Spine-stabilizing muscles in golf players.
    Weishaupt, P
    Obermüller, R
    Hofmann, A
    [J]. SPORTVERLETZUNG-SPORTSCHADEN, 2000, 14 (02) : 55 - 58
  • [5] Biomechanical comparison of the effects of anterior, posterior and transforaminal lumbar interbody fusion on vibration characteristics of the human lumbar spine
    Fan, Wei
    Guo, Li-Xin
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (05) : 490 - 498
  • [6] Anterior instrumentation of the thoracolumbar spine - A biomechanical comparison
    Dick, JC
    Brodke, DS
    Zdeblick, TA
    Bartel, BD
    Kunz, DN
    Rapoff, AJ
    [J]. SPINE, 1997, 22 (07) : 744 - 750
  • [7] BIOMECHANICAL COMPARISON OF ANTERIOR INSTRUMENTATION FOR THE CERVICAL-SPINE
    GRIFFITH, SL
    ZOGBI, SW
    GUYER, RD
    SHELOKOV, AP
    CONTILIANO, JH
    GEIGER, JM
    [J]. JOURNAL OF SPINAL DISORDERS, 1995, 8 (06): : 429 - 438
  • [8] Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model
    Lim, TH
    An, HS
    Hong, JH
    Ahn, JY
    You, JW
    Eck, J
    McGrady, LM
    [J]. SPINE, 1997, 22 (03) : 261 - 266
  • [9] Biomechanical Comparison of Anterior, Posterior, and Circumferential Fixation After One-Level Anterior Cervical Corpectomy in the Human Cadaveric Spine
    Karam, Youssef R.
    Dahdaleh, Nader S.
    Magnetta, Michael J.
    Kim, Byeong-Sam
    Lim, Tae-Hong
    Serhan, Hassan
    Torner, James C.
    Hitchon, Patrick W.
    [J]. SPINE, 2011, 36 (07) : E455 - E460
  • [10] BIOMECHANICAL CONSIDERATIONS ON FRACTURE STABILIZING IMPLANTS
    JENSEN, JS
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (02): : 203 - 203