Development and validation of an LC-ESI-MS/MS method for the determination of nitidine chloride in rat plasma

被引:6
|
作者
Feng, Jie [1 ,2 ]
Yang, Xiu-Wei [1 ]
Huang, Ren-Bin [2 ]
Zhang, Hai-Ying [2 ]
He, Min [2 ]
Huang, Qi-Chun [3 ]
机构
[1] Peking Univ, Sch Pharmaceut Sci, State Key Lab Nat & Biomimet Drugs, Beijing 100191, Peoples R China
[2] Guangxi Med Univ, Sch Pharmaceut Sci, Nanning 530021, Guangxi, Peoples R China
[3] Guangxi Med Univ, Tumor Hosp, Guangxi Tumor Inst & Hosp, Nanning 530021, Guangxi, Peoples R China
关键词
Nitidine chloride; LC-ESI-MS/MS; Pharmacokinetics; IN-VITRO;
D O I
10.1016/j.jchromb.2012.01.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new liquid chromatography-electrospray ionization-mass/mass spectrometry (LC-ESI-MS/MS) assay method has been developed and validated for the quantification of nitidine chloride (NC), an anti-cancer bioactive substance of Zanthoxylum nitidum (Roxb.) DC. plants, in rat plasma using carbamazepine as an internal standard (I.S.). The NC and I.S. were extracted from rat plasma by acetonitrile protein procedure. Chromatographic separation was carried out with a C-18 column (2.1 mm x 150 mm, 3 mu m) with a security guard C-18 column (4 mm x 20 mm, 3 mu m). The mobile phase consisted of acetonitrile-10 mM ammonium acetate buffer solution-formic acid (35:65:0.2, v/v/v) and delivered at the flow rate of 0.25 mL/min. LC-ESI-MS/MS was performed on a triple-quadrupole mass spectrometry equipped with electrospray ionization (ESI) and positive multiple reaction monitoring (MRM). Target ions were monitored at [M](+) m/z 348.2 for NC and [M](+) m/z 237.2 for I.S. The method was linear over the concentration range of 5.0-1500.0 ng/mL. The intra- and inter-day relative standard deviations of the assay were less than 5.0%. The lower limit of quantification was 5.0 ng/mL.. The developed method was successfully applied to the estimation of the pharmacokinetic parameters of NC by intravenous administration to rats. (c) 2012 Elsevier By. All rights reserved.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [1] Determination and Pharmacokinetic Study of Nitidine Chloride in Rat Plasma after Intragastrical Administration by LC-ESI-MS/MS Method
    Dongmei Wang
    Jingfan Zhou
    Xiaobin Zhong
    Jie Feng
    [J]. Chinese Herbal Medicines, 2017, (04) - 380
  • [2] Determination and Pharmacokinetic Study of Nitidine Chloride in Rat Plasma after Intragastrical Administration by LC-ESI-MS/MS Method
    Dong-mei Wang
    Jing-fan Zhou
    Xiao-bin Zhong
    Jie Feng
    [J]. Chinese Herbal Medicines, 2017, 9 (04) : 376 - 380
  • [3] Development and Validation of LC-ESI-MS/MS Method for the Determination of Alfuzosin in Human Plasma
    Rania M. Moustapha E. Moustapha
    Mehnaz El Gamal
    [J]. Journal of Analytical Chemistry, 2021, 76 : 1327 - 1335
  • [4] Development and Validation of LC-ESI-MS/MS Method for the Determination of Alfuzosin in Human Plasma
    Moustapha, Moustapha E.
    El Gamal, Rania M.
    Kamal, Mehnaz
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (11) : 1327 - 1335
  • [5] Development and validation of a LC-ESI-MS/MS method for the determination of swertiamarin in rat plasma and its application in pharmacokinetics
    Li, Hong-Liang
    Peng, Xiao-Jin
    He, Jian-Chang
    Feng, En-Fu
    Xu, Gui-Li
    Rao, Gao-Xiong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (19): : 1653 - 1658
  • [6] Development and Validation of LC-ESI-MS Method for the Quantification of Dapoxetine in Rat Plasma
    Wang, Zhiyi
    Wang, Zhibin
    Chen, Chan
    Wang, Jinjin
    Luo, Shunbin
    Ma, Jianshe
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (01): : 5 - 9
  • [7] LC-ESI-MS/MS Method for the Fosamprenavir Quantification Bioanalytical Method Development and Validation for the Quantification Fosamprenavir in Human Plasma by LC-ESI-MS/MS
    Susmitha, Kondam
    Menaka, Muthukkarupan
    [J]. INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2022, 56 (03) : S599 - S604
  • [8] LC-ESI-MS determination of hydroxycamptothecin in rat plasma
    Liu, Kai
    Sun, Jin
    Wang, Yongjun
    Gao, Kun
    Wen, Bing
    He, Yuan
    He, Zhonggui
    [J]. CHROMATOGRAPHIA, 2008, 67 (9-10) : 833 - 836
  • [9] A Sensitive Bioanalytical Method Development And Validation Of Pazopanib In Human Plasma By LC-ESI-MS/MS
    Annapurna, M.
    Shanthi, Priya D. K.
    [J]. JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 855 - 861
  • [10] A sensitive bioanalytical method development and validation of cabozantinib in human plasma by LC-ESI-MS/MS
    Inturi, Srikanth
    Avula, Prameela Rani
    [J]. BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 54 (02)