Single-center experience of ultra-high-density mapping guided catheter ablation of focal atrial tachycardia

被引:3
|
作者
Kellnar, Antonia [1 ]
Fichtner, Stephanie [1 ]
Mehr, Michael [1 ]
Czermak, Thomas [1 ]
Sinner, Moritz F. [1 ,2 ]
Lackermair, Korbinian [1 ]
Estner, Heidi L. [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp Munich, Dept Med 1, Munich, Germany
[2] German Cardiovasc Res Ctr DZHK, Partner Site Munich Heart Alliance, Munich, Germany
关键词
3D mapping; ablation; atrial tachycardia; high density; Orion; rhythmia; FIBRILLATION;
D O I
10.1002/clc.23774
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Catheter ablation is the treatment of choice for recurrent focal atrial tachycardia (FAT) as medical therapy is limited. Routinely, a three-dimensional mapping system is used. Whether or not optimized signal detection does improve ablation success rates has not yet been investigated. This retrospective cohort study compared ablation procedures using an ultra-high-density mapping system (UHDM, Rhythmia, Boston Scientific) with improved signal detection and automatic annotation with procedures using a conventional electroanatomic mapping system (CEAM, Biosense Webster, CARTO). Methods All patients undergoing ablation for FAT using UHDM or CEAM from April 2015 to August 2018 were included. Endpoints comprised procedural parameters, acute success as well as freedom from arrhythmia 12 months after ablation. Results A total of 70 patients underwent ablation (48 with UHDM, 22 with CEAM). No significant differences were noted for parameters like procedural and radiation duration, area dose, and RF applications. Acute success was significantly higher in the UHDM cohort (89.6% vs. 68.2%, p = .03). Nevertheless, arrhythmia freedom 12 months after ablation was almost identical (56.8% vs. 60%, p = .87), as more patients with acute success of ablation presented with a relapse during follow-up (35.0 vs. 7.7%, p = .05). Conclusion Acute success rate of FAT ablation might be improved by UHDM, without an adverse effect on procedural parameters. Nevertheless, further research is needed to understand the underlying mechanism for increased recurrence rates after acute successful ablation.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [1] Outcome after tailored catheter ablation of atrial tachycardia using ultra-high-density mapping
    Jungen, Christiane
    Akbulak, Ruken
    Kahle, Ann-Kathrin
    Eickholt, Christian
    Schaeffer, Benjamin
    Scherschel, Katharina
    Dinshaw, Leon
    Muenkler, Paula
    Schleberger, Ruben
    Nies, Moritz
    Gunawardene, Melanie A.
    Klatt, Niklas
    Hartmann, Jens
    Merbold, Lydia
    Jularic, Mario
    Willems, Stephan
    Meyer, Christian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (10) : 2645 - 2652
  • [2] 10-year single center experience of catheter ablation of focal atrial tachycardia
    John Whitaker
    Nathaniel Steiger
    Jorge Romero
    Sunil Kapur
    Thomas Tadros
    William H. Sauer
    Paul C. Zei
    Usha Tedrow
    Bruce Koplan
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1135 - 1144
  • [3] 10-year single center experience of catheter ablation of focal atrial tachycardia
    Whitaker, John
    Steiger, Nathaniel
    Romero, Jorge
    Kapur, Sunil
    Tadros, Thomas
    Sauer, William H.
    Zei, Paul C.
    Tedrow, Usha
    Koplan, Bruce
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (05) : 1135 - 1144
  • [4] Complications of Catheter Ablation of Ventricular Tachycardia A Single-Center Experience
    Peichl, Petr
    Wichterle, Dan
    Pavlu, Ludek
    Cihak, Robert
    Aldhoon, Bashar
    Kautzner, Josef
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (04): : 684 - 690
  • [5] The impact of ultra-high-density mapping on long-term outcome after catheter ablation of ventricular tachycardia
    Schleberger, Ruben
    Schwarzl, Jana M.
    Moser, Julia
    Nies, Moritz
    Hoeller, Alexandra
    Muenkler, Paula
    Dinshaw, Leon
    Jungen, Christiane
    Lemoine, Marc D.
    Maury, Philippe
    Sacher, Frederic
    Martin, Claire A.
    Wong, Tom
    Estner, Heidi L.
    Jais, Pierre
    Willems, Stephan
    Eickholt, Christian
    Meyer, Christian
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] The impact of ultra-high-density mapping on long-term outcome after catheter ablation of ventricular tachycardia
    Ruben Schleberger
    Jana M. Schwarzl
    Julia Moser
    Moritz Nies
    Alexandra Höller
    Paula Münkler
    Leon Dinshaw
    Christiane Jungen
    Marc D. Lemoine
    Philippe Maury
    Frederic Sacher
    Claire A. Martin
    Tom Wong
    Heidi L. Estner
    Pierre Jaïs
    Stephan Willems
    Christian Eickholt
    Christian Meyer
    Scientific Reports, 12
  • [7] Catheter ablation of ventricular tachycardia in the pediatric patients: A single-center experience
    Wu, Jinjin
    Chen, Yiwei
    Ji, Wei
    Gu, Beiyin
    Shen, Jie
    Fu, Lijun
    Li, Fen
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (01): : 37 - 46
  • [8] Atypical Atrial Flutter Ablation Utilizing Ultra-High-Density Activation Mapping
    Romanowicz, Katherine C.
    Athar, Muhammad W.
    Costea, Alexandru I.
    CIRCULATION, 2021, 144
  • [9] Single-Center Experience of Catheter Ablation for Atrial Fibrillation Using Multi-Electrode Mapping and Ablation Catheters
    Zeb, Mehmood
    Yue, Arthur
    Scott, Paul Andrew
    Roberts, Paul R.
    Morgan, John M.
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (10): : 407 - 413
  • [10] Catheter ablation of atrial arrhythmias by using a multipolar grid-patterned high density mapping catheter in patients with congenital heart disease: a single-center experience
    Kerst, G.
    Gulgun, M.
    Ozcan, S.
    Ostenmayer, S.
    Hartmann, L.
    Hanten, J.
    Vazquez-Jimenez, J.
    EUROPEAN HEART JOURNAL, 2022, 43 : 642 - 642