Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis

被引:89
|
作者
Zhao, Lei
Tian, Zhuang
Fang, Quan [1 ]
机构
[1] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Cardiol, 1 Shuaifuyuan, Beijing 100730, Peoples R China
来源
关键词
Cardiac amyloidosis; Cardiac magnetic resonance; LGE; Meta-analysis; ENDOMYOCARDIAL BIOPSY; T1; CMR; AL; QUANTIFICATION; INVOLVEMENT; MANAGEMENT; DISEASE; PROVEN;
D O I
10.1186/s12872-016-0311-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study is a systematic review and meta-analysis of the diagnostic value of cardiovascular magnetic resonance (CMR) in cardiac amyloidosis (CA). Methods: A wide variety of electronic databases were searched for studies of CMR that reported the diagnostic accuracy in patients with suspected CA. Research manuscripts were subjected to further systematic review and meta-analysis. Methodological evaluation was performed under the guidance of the Quality Assessment of Diagnostic Accuracy Studies -2 (QUADAS-2). Heterogeneity was assessed, and a random-effects model was used to assess the diagnostic effects of CMR on pooled sensitivity, pooled specificity, and summary receiver operating characteristics (SROC). Results: Seven studies that reported the performance of CMR for CA were included in the present systematic review, among which five studies (257 patients) that evaluated the diagnostic accuracy of late gadolinium enhancement (LGE) CMR were analyzed in the present meta-analysis. Heterogeneity was observed only in specificity. A summary sensitivity and specificity of 85 % (95 % CI: 77-91 %) and 92 % (95 % CI: 83-97 %) indicated a high diagnostic accuracy of LGE for CA. The AUC of SROC curve was 0.9530, suggesting that LGE is an effective way of diagnosing patients with possible cardiac involvement in amyloidosis. Conclusions: LGE-CMR seems to have a relatively high diagnostic accuracy for amyloidosis patients with possible cardiac involvement. Combined CMR techniques may provide important information for the selection of suitable therapy.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis
    Lei Zhao
    Zhuang Tian
    Quan Fang
    BMC Cardiovascular Disorders, 16
  • [2] Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis A Systematic Review and Meta-Analysis
    Kotanidis, Christos P.
    Bazmpani, Maria-Anna
    Haidich, Anna-Bettina
    Karvounis, Charalambos
    Antoniades, Charalambos
    Karamitsos, Theodoros D.
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (11) : 1583 - 1590
  • [3] Diagnostic accuracy of elastography and magnetic resonance imaging in patients with NAFLD: A systematic review and meta-analysis
    Selvaraj, Emmanuel Anandraj
    Mozes, Ferenc Emil
    Jayaswal, Arjun Narayan Ajmer
    Zafarmand, Mohammad Hadi
    Vali, Yasaman
    Lee, Jenny A.
    Levick, Christina Kim
    Young, Liam Arnold Joseph
    Palaniyappan, Naaventhan
    Liu, Chang-Hai
    Aithal, Guruprasad Padur
    Romero-Gomez, Manuel
    Brosnan, M. Julia
    Tuthill, Theresa A.
    Anstee, Quentin M.
    Neubauer, Stefan
    Harrison, Stephen A.
    Bossuyt, Patrick M.
    Pavlides, Michael
    JOURNAL OF HEPATOLOGY, 2021, 75 (04) : 770 - 785
  • [4] Diagnostic Accuracy of Cardiac Magnetic Resonance Versus Fractional Flow Reserve: A Systematic Review and Meta-Analysis
    Ullah, Waqas
    Roomi, Sohaib
    Abdullah, Hafez M.
    Mukhtar, Maryam
    Ali, Zain
    Ye, Ping
    Haas, Donald C.
    Figueredo, Vincent M.
    CARDIOLOGY RESEARCH, 2020, 11 (03) : 145 - 154
  • [5] Diagnostic accuracy of bone scintigraphy imaging for transthyretin cardiac amyloidosis: systematic review and meta-analysis
    Ahluwalia, Nanki
    Roshankar, Golnaz
    Draycott, Logan
    Jimenez-Zepeda, Victor
    Fine, Nowell
    Chan, Denise
    Han, Donghee
    Miller, Robert J. H.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) : 2464 - 2476
  • [6] Diagnostic accuracy of bone scintigraphy imaging for transthyretin cardiac amyloidosis: systematic review and meta-analysis
    Nanki Ahluwalia
    Golnaz Roshankar
    Logan Draycott
    Victor Jimenez-Zepeda
    Nowell Fine
    Denise Chan
    Donghee Han
    Robert J. H. Miller
    Journal of Nuclear Cardiology, 2023, 30 : 2464 - 2476
  • [7] Diagnostic Accuracy Of Bone Scintigraphy Imaging For Transthyretin Cardiac Amyloidosis: Systematic Review And Meta-Analysis
    Ahluwalia, Nanki
    Roshankar, Golnaz
    Jimenez-Zepeda, Victor
    Fine, Nowell
    Denise, Chan
    Han, Donghee
    Miller, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [8] Accuracy of Diagnostic Ultrasound in Patients With Suspected Subacromial Disorders: A Systematic Review and Meta-Analysis
    Ottenheijm, Ramon P.
    Jansen, Mariette J.
    Staal, J. Bart
    van den Bruel, Ann
    Weijers, Rene E.
    de Bie, Rob A.
    Dinant, Geert-Jan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (10): : 1616 - 1625
  • [9] Tissue mapping by cardiac magnetic resonance imaging for the prognostication of cardiac amyloidosis: A systematic review and meta-analysis
    Cai, Sean
    Haghbayan, Hourmazd
    Chan, Kelvin K. W.
    Deva, Djeven P.
    Jimenez-Juan, Laura
    Connelly, Kim A.
    Ng, Ming-Yen
    Yan, Raymond T.
    Yan, Andrew T.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 403
  • [10] Diagnostic accuracy of magnetic resonance imaging in patients with suspected pulmonary embolism: A bivariate meta-analysis
    Squizzato, Alessandro
    Pomero, Fulvio
    Allione, Attilio
    Priotto, Roberto
    Riva, Nicoletta
    Huisman, Menno V.
    Klok, Frederikus A.
    Stein, Paul D.
    Guasti, Luigina
    Fenoglio, Luigi
    Dentali, Francesco
    Ageno, Walter
    THROMBOSIS RESEARCH, 2017, 154 : 64 - 72