Long range neutron-gamma point source detection and imaging using unique rotating detector

被引:7
|
作者
Lacy, Jeffrey L. [1 ]
Athanasiades, Athanasios [1 ]
Martin, Christopher S. [1 ]
Sun, Liang [1 ]
Anderson, Jeffry W. [1 ]
Lyons, Tom D. [1 ]
机构
[1] Proport Technol Inc, Houston, TX 77054 USA
关键词
D O I
10.1109/NSSMIC.2007.4436313
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a new radiation detection technology that offers high sensitivity to both gamma rays and neutrons, and can be applied, cost effectively, to survey monitoring. The detector consists of a close-packed array of many small thin-walled copper straws, each 1 m in length, and lined with a very thin (1 mu m) coating of enriched boron carbide ((B4C)-B-10). Gammas are converted in Cu, while thermal neutrons are converted in B-10. The detector design draws upon low-cost technology developed by the high energy physics community for large particle detectors such as ATLAS, currently being commissioned at CERN. The feasibility of the detection technology has been demonstrated previously [1], [2]. The current work presents a unique application of the straw detectors, whereby a rotating panel is used to significantly improve performance. The proposed concept is based on the characteristic signature of a point source, that differentiates it from background noise. We present and evaluate an algorithm for detecting the presence of a source and estimating its net count, direction, and the background rate. Simulation results show that the proposed technique can detect in about 20 minutes time and in an area 100 m in diameter, a 1 mCi gamma ray source, with 90% sensitivity and false alarm probability of 0.1/hour. At 30 min time, 270 g of neutron-emitting Pu-240 can be detected within a circular area 100 m in diameter, assuming 20% of neutrons thermalize near the source.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 50 条
  • [1] Fabrication and Materials for a Long Range Neutron-Gamma Monitor Using Straw Detectors
    Lacy, Jeffrey L.
    Athanasiades, Athanasios
    Martin, Christopher S.
    Sun, Liang
    Lyons, Tom D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5619 - 5624
  • [2] A New Multi-Layer Scintillation Detector for Detection of Neutron-Gamma Radiation
    Ryzhikov, V. D.
    Naydenov, S. V.
    Onyshchenko, G. M.
    Piven, L. A.
    Zvereva, V. S.
    Pochet, T.
    Smith, C. F.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Digital signal processing for neutron-gamma discrimination using a liquid scintillator detector
    Biganeh, A.
    Azizi, M.
    Kakuee, O.
    Rafi-Kheiri, H.
    Boorkhani, M. Sedaghati
    Ghasemi, B.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [4] Development of a CLYC-based wide dose rate range portable neutron-gamma detector
    Huang, Yuliang
    Zhao, Keqing
    Shan, Chenyu
    Feng, Changqing
    Wang, Yichao
    Wang, Ziqi
    Chang, Kang
    Liu, Feng
    Xie, Wenzhang
    Liu, Shubin
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [5] Improved neutron-gamma discrimination for a 3He neutron detector using subspace learning methods
    Wang, C. L.
    Funk, L. L.
    Riedel, R. A.
    Berry, K. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 853 : 27 - 35
  • [6] A method for determining density based on gamma ray and fast neutron detection using a Cs2LiYCl6 detector in neutron-gamma density logging
    Zhang, Quanying
    Zhang, Feng
    Gardner, Robin P.
    Yan, Huizhong
    Wu, Guoli
    Tian, Lili
    Chen, Qian
    Ti, Yongzhou
    APPLIED RADIATION AND ISOTOPES, 2018, 142 : 77 - 84
  • [7] Digital neutron-gamma discrimination in a wide energy range using pulse reconstruction method
    Jamili, S.
    Bayat, E.
    Afarideh, H.
    Davani, F. Abbasi
    Ghal-Eh, N.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 109 : 13 - 16
  • [8] First measurement of neutron emission profile on JT-60U using Stilbene neutron detector with neutron-gamma discrimination
    Ishikawa, M
    Nishitani, T
    Morioka, A
    Takechi, M
    Shinohara, K
    Shimada, M
    Miura, Y
    Nagami, M
    Kaschuck, YA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (12): : 4237 - 4242
  • [9] FEASIBILITY STUDY ON USING IMAGING PLATES TO ESTIMATE THERMAL NEUTRON FLUENCE IN NEUTRON-GAMMA MIXED FIELDS
    Fujibuchi, Toshioh
    Tanabe, Yu
    Sakae, Takeji
    Terunuma, Toshiyuki
    Isobe, Tomonori
    Kawamura, Hiraku
    Yasuoka, Kiyoshi
    Matsumoto, Tetsuro
    Harano, Hideki
    Nishiyama, Jun
    Masuda, Akihiko
    Nohtomi, Akihiro
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 394 - 400
  • [10] Improved neutron-gamma discrimination for a 6Li-glass neutron detector using digital signal analysis methods
    Wang, C. L.
    Riedel, R. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (01):