Technical note: Comparison of radial immunodiffusion and ELISA for quantification of bovine immunoglobulin G in colostrum and plasma

被引:68
|
作者
Gelsinger, S. L. [1 ]
Smith, A. M. [1 ]
Jones, C. M. [1 ]
Heinrichs, A. J. [1 ]
机构
[1] Penn State Univ, Dept Anim Sci, University Pk, PA 16802 USA
关键词
radial immunodiffusion; ELISA; IgG; calf; colostrum; HEAT-TREATED COLOSTRUM; PASSIVE TRANSFER; VISCOSITY;
D O I
10.3168/jds.2014-8491
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Historically, radial immunodiffusion (RID) has been the only method that directly measures IgG; however, recent studies have reported IgG concentrations in colostrum, milk, and plasma as measured using an ELISA. To our knowledge no comparison between RID and ELISA methods has been made for bovine colostrum or plasma. The objective of this study was to compare IgG concentrations measured by both methods in samples of bovine colostrum before and after heat treatment and bovine plasma. Concentration of IgG was quantified using a commercially available RID kit and a modified ELISA. Samples of bovine colostrum and plasma were collected from individual animals and colostrum was tested before and after heat treatment at 60 degrees C for 30 min. All samples were tested using both methods. Pearson correlation coefficients were determined for RID and ELISA values from unheated colostrum, heat-treated colostrum, and plasma samples. Mixed models were used to determine the effect of assay on IgG measurement in colostrum and plasma and effect of heat treatment on IgG concentration in colostrum. A weak correlation was found between ELISA and RID results in plasma and unheated colostrum. Concentration of IgG was significantly lower in all sample types when measured by ELISA compared to RID. Thus, direct comparison of ELISA and RID results is not recommended. Colostrum IgG concentration significantly decreased after heat treatment as measured by ELISA, but means were not different when measured by RID. Correlation plots between colostrum values measured before and after heat treatment indicated changes in the colostrum protein matrix due to heat affected RID and ELISA assays differently. This investigation compared RID and ELISA results, but no conclusions could be drawn as to the accuracy of either assay.
引用
收藏
页码:4084 / 4089
页数:6
相关论文
共 50 条
  • [1] Comparison of single radial immunodiffusion and ELISA for the quantification of immunoglobulin G in bovine colostrum, milk and calf sera
    Dunn, Amanda
    Duffy, Catherine
    Gordon, Alan
    Morrison, Steven
    Arguello, Anastasio
    Welsh, Michael
    Earley, Bernadette
    JOURNAL OF APPLIED ANIMAL RESEARCH, 2018, 46 (01) : 758 - 765
  • [2] Comparison of two commercial radial immunodiffusion assays for detection of bovine immunoglobulin G in newborn calves
    Ameri, Mehrdad
    Wilkerson, Melinda J.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2008, 20 (03) : 333 - 336
  • [3] Comparison of radial immunodiffusion, turbidimetric immunoassay, and Brix refractometry for determining bovine colostrum quality
    Westhoff, T. A.
    Behling-Kelly, E. L.
    Mann, S.
    JDS COMMUNICATIONS, 2024, 5 (06):
  • [4] Sources of variance in the results of a commercial bovine immunoglobulin G radial immunodiffusion assay
    Thompson, Alexis C. C.
    Wills, Robert W. W.
    Smith, David R. R.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2023, 35 (01) : 34 - 41
  • [5] Affinity liquid chromatography method for the quantification of immunoglobulin G in bovine colostrum powders
    Copestake, David E. J.
    Indyk, Harvey E.
    Otter, Don E.
    JOURNAL OF AOAC INTERNATIONAL, 2006, 89 (05) : 1249 - 1256
  • [6] Characterisation of an ELISA detecting immunoglobulin G to Mycobacterium avium subsp paratuberculosis in bovine colostrum
    Zervens, Lisa Marie-Louise
    Nielsen, Soren Saxmose
    Jungersen, Gregers
    VETERINARY JOURNAL, 2013, 197 (03): : 889 - 891
  • [7] Prevalence of immunoglobulin G in bovine colostrum and colostrum replacement products
    Son, Y. M.
    Choi, K-H
    Seo, J. S.
    Lee, K.
    Hwang, M-H
    Jung, B. Y.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2017, 50 : S163 - S164
  • [8] COMPARISON OF IMMUNOGLOBULIN METHODS - TURBIDIMETRIC, NEPHELOMETRIC, RADIAL IMMUNODIFFUSION
    HAVEN, MC
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1071 - 1071
  • [9] Comparison of serum immunoglobulin G half-life in dairy calves fed colostrum, colostrum replacer or administered with intravenous bovine plasma
    Murphy, Jacob M.
    Hagey, Jill V.
    Chigerwe, Munashe
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2014, 158 (3-4) : 233 - 237
  • [10] NOTE ON BOVINE COLOSTRUM AS AN ALTERNATIVE SOURCE OF IMMUNOGLOBULIN FOR LAMBS
    LOGAN, EF
    FOSTER, WH
    IRWIN, D
    ANIMAL PRODUCTION, 1978, 26 (FEB): : 93 - 96