摘要
Purpose: Gold fiducial markers are used to guide liver stereotactic body radiation therapy (SBRT) and are hard to detect by magnetic resonance imaging (MRI). In this study, the parameters of the three-dimensional Tl-weighted turbo gradient-echo (3D T1W-GRE) sequence were optimized for gold marker detection without degrading tumor delineation. Methods: Custom-made phantoms mimicking tumor and normal liver parenchyma were prepared and embedded with a gold marker. The 3D T1W-GRE was scanned by varying echo time (TE), bandwidth (BW), flip angle (FA), and base matrix size. The signal-to-noise ratio (SNR), contrast ratio (CR), and relative standard deviation (RSD) of the signal intensity in the area including the gold marker were evaluated, and the parameters were optimized accordingly. The modified 3D T1W-GRE (called HYBRID) was compared with the conventional T1W-GRE- and T2*-sequences in both phantom and clinical studies. In the clinical study of six patients with primary liver tumors, two observers visually assessed marker detection, tumor delineation, and overall image quality on a four-point scale. Results: In the phantom study, HYBRID showed significantly higher SNR and RSD than those of conventional T1W-GRE (P < 0.001). In the clinical study, HYBRID yielded significantly higher scores than conventional T1W-GRE did in terms of marker detection (P < 0.001). The scores of both sequences were not statistically different in terms of tumor delineation and overall image quality (P = 0.56 and P = 0.32). Conclusions: The proposed HYBRID sequence improved gold fiducial marker detection without degrading tumor delineation in MRI for SBRT of primary liver tumor.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [1] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424
  • [2] MR venography: True FISP sequence versus Gadolinium-enhanced 3d T1-weighted gradient-echo sequence
    Pedrosa, I
    Yu, J
    Mahallati, H
    Bryer, HP
    Morrin, MM
    Rofsky, NM
    RADIOLOGY, 2002, 225 : 359 - 360
  • [3] Diagnostic value of 3D T1-weighted gradient-echo and 2D T1-weighted in-phase and out-of-phase gradient-echo sequences for appendicitis diagnosis in pregnant women
    Hung, Nguyen Duy
    Dung, Le Thanh
    Dung, Nguyen-Thi Kim
    Ha Khuong, Nguyen
    Anh, Nguyen Hai
    Duc, Nguyen Minh
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2023, 13 : 1 - 6
  • [4] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [5] Hyperintense nodules on non-enhanced T1-weighted gradient-echo magnetic resonance imaging of cirrhotic liver: Fate and clinical implications
    Yu, Jeong-Sik
    Lee, Jei Hee
    Park, Mi-Suk
    Kim, Ki Whang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 630 - 636
  • [6] The value of 3D T1-weighted gradient-echo MR imaging for evaluation of the appendix during pregnancy: preliminary results
    Jang, Kyung Mi
    Kim, Seong Hyun
    Choi, Dongil
    Lee, Soon Jin
    Rhim, Hyunchul
    Park, Min Jung
    ACTA RADIOLOGICA, 2011, 52 (08) : 825 - 828
  • [7] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [8] Evaluation of Fetal Thyroid with 3D Gradient Echo T1-weighted MR Imaging
    Fujii, Shinya
    Nagaishi, Junichi
    Mukuda, Naoko
    Kaneda, Sachi
    Inoue, Chie
    Fukunaga, Takeru
    Ogawa, Toshihide
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 203 - 208
  • [9] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Jeong Hee Yoon
    Jeong Min Lee
    Eun Sun Lee
    Jeehyun Baek
    Sangwoo Lee
    Yuji Iwadate
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 278 - 288
  • [10] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Yoon, Jeong Hee
    Lee, Jeong Min
    Lee, Eun Sun
    Baek, Jeehyun
    Lee, Sangwoo
    Iwadate, Yuji
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (02): : 278 - 288