Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography

被引:2
|
作者
Park, Jae Seok [1 ]
Jeong, Myung Yung [1 ]
Kim, Chang-Seok [1 ]
机构
[1] Pusan Natl Univ, WCU Program, Dept Cognomechatron, Pusan 609735, South Korea
关键词
Optical coherence tomography; Common-path interferometer; Biological imaging; DOMAIN REFLECTOMETRY; INTERFEROMETER; SYSTEM;
D O I
10.3807/JOSK.2011.15.4.380
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Common-path interferometers are widely used for endoscopic optical coherence tomography (OCT) because an arbitrary arm length can be chosen for the endoscopic imaging probe. However, the scheme suffers from the limited range of the sample position distance from the end of the imaging probe because the position between the reference reflector and the sample is limited by the optical path-length difference (OPD) to induce an interference signal. In this study, we developed a novel method for compensating the arbitrary sample position in common-path swept-source OCT by adding an extra Mach-Zehnder interferometer in the post-path of the interfered optical signal. Theoretical analysis and an experimental demonstration of imaging depth tuning for the flexible sample position of an endoscopic OCT image are discussed. After post-tuning of sample position distance, the positioning limitation between the reference reflector and the sample can be solved for various sample positions over a range of 26 mm for the cross-sectional images of a fish eye sample.
引用
收藏
页码:380 / 385
页数:6
相关论文
共 50 条
  • [21] Evaluation of choroidal lesions with swept-source optical coherence tomography
    Ung, Cindy
    Lains, Ines
    Silverman, Rebecca F.
    Woods, Russell
    Lane, Anne Marie
    Papakostas, Thanos D.
    Husain, Deeba
    Miller, Joan W.
    Gragoudas, Evangelos S.
    Kim, Ivana K.
    Miller, John B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (01) : 88 - 93
  • [22] The Latest Updates in Swept-Source Optical Coherence Tomography Angiography
    Xia, Fan
    Hua, Rui
    DIAGNOSTICS, 2024, 14 (01)
  • [23] Cataract quantification using swept-source optical coherence tomography
    Panthier, Christophe
    Saad, Main
    Rouger, Helene
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 893 - 894
  • [24] Swept-source optical coherence tomography in a retinal astrocytic hamartoma
    Bastons-Compta, C.
    Moix-Gil, E.
    Huanca, H. G.
    Baradad, M. C.
    Lorenzo, D.
    Caminal, J. M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2020, 43 (07): : 683 - 686
  • [25] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257
  • [26] Swept-source optical coherence tomography imaging of the retinochoroid and beyond
    Vira, Jayesh
    Marchese, Alessandro
    Singh, Rohan Bir
    Agarwal, Aniruddha
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (05) : 413 - 426
  • [27] Swept-source optical coherence tomography findings in peripheral drusen
    Kumar, Vinod
    Tewari, Ruchir
    Chandra, Parijat
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (12) : 930 - 931
  • [28] Active depth-locking handheld micro-injector based on common-path swept source optical coherence tomography
    Cheon, Gyeong-Woo
    Huang, Yong
    Kang, Jin U.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XV, 2015, 9317
  • [29] Lamina cribrosa surface position in idiopathic intracranial hypertension with swept-source optical coherence tomography
    Pasaoglu, Isil
    Satana, Banu
    Altan, Cigdem
    Artunay, Ozgur
    Basarir, Berna
    Onmez, Funda E.
    Inal, Asli
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) : 1085 - 1088
  • [30] Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2010, 14 (01) : 1 - 13