Real-Time QCM-D Monitoring of the Adsorption-Desorption of Expansin on Lignin

被引:12
|
作者
Cui, Mei [2 ]
Duan, Yuhao [2 ]
Ma, Yuanyuan [3 ]
Al-Shwafy, Khaled W. A. [2 ]
Liu, Yudong [2 ]
Zhao, Xudong [2 ]
Huang, Renliang [1 ]
Qi, Wei [2 ,4 ]
He, Zhonghe [2 ]
Su, Rongxin [2 ,4 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Chem Engn & Technol, State Key Lab Chem Engn, Tianjin Key Lab Membrane Sci & Desalinat Technol, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Sch Chem Engn & Technol, Biomass Convers Lab, Tianjin Univ R&D Ctr Petrochem Technol, Tianjin 300072, Peoples R China
[4] Collaborat Innovat Ctr Chem Sci & Engn Tianjin, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
ENZYMATIC-HYDROLYSIS; BACTERIAL EXPANSIN; FUNCTIONAL-CHARACTERIZATION; BACILLUS-SUBTILIS; LIGNOCELLULOSE; CONVERSION; PROTEINS; CELLULASE; KINETICS; ENZYMES;
D O I
10.1021/acs.langmuir.0c00104
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Expansin has nonhydrolytic disruptive activity and synergistically acts with cellulases to enhance the hydrolysis of cellulose. The adsorption-desorption of expansin on noncellulosic lignin can greatly affect the action of expansin on lignocellulose. In this study, three lignins with different sources (kraft lignin (KL), sodium lignin sulfonate (SLS), and enzymatic hydrolysis lignin (EHL)) were selected as the substrates. The real-time adsorption-desorption of Bacillus subtilis expansin (BsEXLX1) on lignins was monitored using quartz crystal microgravimetry with dissipation (QCM-D). The effects of temperature and Tween 80 on the adsorption-desorption behaviors were also investigated. The results show that BsEXLX1 exhibited high binding ability on lignin and achieved maximum adsorption of 283.2, 273.8, and 266.9 ng cm(-2) at 25 degrees C on KL, SLS, and EHL, respectively. The maximum adsorption decreased to 148.2-192.8 ng cm(-2) when the temperature increased from 25 to 45 degrees C. Moreover, Tween 80 competitively bound to lignin and significantly prevented expansin adsorption. After irreversible adsorption of Tween 80, the maximum adsorption of BsEXLX1 greatly decreased to 33.3, 37.2, and 10.3 ng cm(-2) at 25 degrees C on la, SLS, and EHL, respectively. Finally, a kinetic model was developed to analyze the adsorption- desorption process of BsEXLX1. BsEXLX1 has a higher adsorption rate constant (k(A)) and a lower desorption rate constant (k(D)) on KL than on SLS and EHL. The findings of this study provide useful insights into the adsorption-desorption of expansin on lignin.
引用
收藏
页码:4503 / 4510
页数:8
相关论文
共 50 条
  • [1] QCM-D real-time monitoring of structural changes in an adsorbed protein layer
    Zelander, G
    NATURE METHODS, 2006, : 41 - 42
  • [2] Real-time QCM-D monitoring of cellular responses to different cytomorphic agents
    Fatisson, Julien
    Azari, Fereshteh
    Tufenkji, Nathalie
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (07): : 3207 - 3212
  • [3] Real-time QCM-D monitoring of cancer cell death early events in a dynamic context
    Nowacki, Laetitia
    Follet, Julie
    Vayssade, Muriel
    Vigneron, Pascale
    Rotellini, Laura
    Cambay, Florian
    Egles, Christophe
    Rossi, Claire
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 469 - 476
  • [4] Non-Invasive Real-Time Study of Cell Adhesion using Dissipation Monitoring of the QCM-D
    Chen, Jennifer Y.
    Garcia, Marcela P.
    Penn, Lynn S.
    Xi, Jun
    BIOPHYSICAL JOURNAL, 2013, 104 (02) : 528A - 528A
  • [5] Real-time monitoring of mechanical changes during dynamic adhesion of erythrocytes to endothelial cells by QCM-D
    Zhang, Shaolian
    Bai, Haihua
    Yang, Peihui
    CHEMICAL COMMUNICATIONS, 2015, 51 (57) : 11449 - 11451
  • [6] Using QCM-D for Real-Time Analysis of Cell Adhesion Dynamics at Biointerfaces
    Rogala, Agnes
    Tiainen, Hanna
    Zaytseva-Zotova, Daria
    ADVANCED MATERIALS INTERFACES, 2024,
  • [7] Adsorption-desorption noise in QCM gas sensors
    Sedlak, Petr
    Sikula, Josef
    Majzner, Jiri
    Vrnata, Martin
    Fitl, Premysl
    Kopecky, Dusan
    Vyslouzil, Filip
    Handel, Peter H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 264 - 268
  • [8] A real-time QCM-D approach to monitoring mammalian DNA damage using DNA adsorbed to a polyelectrolyte surface
    Rawle, Robert J.
    Johal, Malkiat S.
    Selassie, Cynthia R. D.
    BIOMACROMOLECULES, 2008, 9 (01) : 9 - 12
  • [9] Real-Time QCM-D Monitoring of Electrostatically Driven Lipid Transfer between Two Lipid Bilayer Membranes
    Wikstrom, Angelica
    Svedhem, Sofia
    Sivignon, Marc
    Kasemo, Bengt
    JOURNAL OF PHYSICAL CHEMISTRY B, 2008, 112 (44): : 14069 - 14074
  • [10] Real-Time QCM-D Monitoring of Deposition of Gold Nanorods on a Supported Lipid Bilayer as a Model Cell Membrane
    Guo, Huxiang
    Xing, Qiguo
    Huang, Renliang
    Lee, Dong Woog
    Su, Rongxin
    Qi, Wei
    He, Zhimin
    ACS OMEGA, 2019, 4 (03): : 6059 - 6067