Experimental investigation of cold start emission using preheating system on the exhaust line at the idle conditions on a spark ignition engine

被引:2
|
作者
Aktas, Fatih [1 ]
Dinler, Nureddin [1 ]
Karaaslan, Salih [1 ]
Turker, Ahmet [1 ]
Yucel, Nuri [1 ]
机构
[1] Gazi Univ, Fac Engn, Dept Mech Engn, TR-06570 Ankara, Turkey
关键词
Three-way catalytic converter; preheating; exhaust emissions; light-off; cold start; SI engine; ELECTRICALLY HEATED CATALYST; INTERNAL-COMBUSTION ENGINES; CONVERTER; TEMPERATURE; PERFORMANCE; GASOLINE; ETHANOL;
D O I
10.1007/s12046-021-01658-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In an ideal conditions, three-way catalytic converters have a structure that will convert almost all of the harmful exhaust emissions. However, these conditions are not valid for cold start and idle conditions. Especially in cold weather, people wait for a while at the idle speed even though it is not a good way to warm up the engine. In this period, since the required temperature to reach light-off values are not provided, the emission released to the environment is at the highest level. The effects of preheating of the catalytic converter have been investigated in order to minimize the exhaust gases emitted under cold and idle working conditions and to meet the Euro standards as soon as possible after the emission release starts. In this experimental study, preheating of 1060, 1253 and 1493 Watt energy was applied to the exhaust line before the three-way catalytic converter at the cold start and idle conditions. Preheating was started when the engine started running. In the experiments, temperature and emission values were obtained at the catalytic converter inlet and outlet at idle conditions (1000 rpm) for about 430 seconds. The effects of inlet temperatures of exhaust gases on HC and CO emission behavior and converter conversion efficiency were investigated. When 1060, 1253 and 1493 Watt preheating are applied to the exhaust line, the times for reaching the light-off for HC and CO emissions occur at 395, 295, 220 and 369, 277, 200 seconds, respectively. However, when preheating is not applied, the catalytic converter has not been able to reach the light-off within the specified time. Finally, the EURO VI standard could not be achieved for the specified period without preheating. However, when the preheating load was set to 1493 Watt, EURO VI standards were achieved at the end of 310 and 285 seconds preheating times for both HC and CO emissions.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Experimental investigation of cold start emission using preheating system on the exhaust line at the idle conditions on a spark ignition engine
    FATIH AKTAS
    NUREDDIN DINLER
    SALIH KARAASLAN
    AHMET TURKER
    NURI YUCEL
    Sādhanā, 2021, 46
  • [2] EXPERIMENTAL INVESTIGATION OF COLD START EMISSIONS USING ELECTRICALLY HEATED CATALYSTS IN A SPARK IGNITION ENGINE
    Bhaskar, K.
    Nagarajan, G.
    Sampath, S.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2010, 2 : 105 - 118
  • [3] Modeling and Simulation of Engine Speed on Idle Speed Conditions System by using MIMO on Spark Ignition Engine
    Irianto
    Wulandari, Irma
    INNOVATIVE SCIENCE AND TECHNOLOGY IN MECHANICAL ENGINEERING FOR INDUSTRY 4.0, 2019, 2187
  • [4] Investigation of Exhaust Emissions of Vehicles with the Spark Ignition Engine within Emission Control
    Sarkan, Branislav
    Stopka, Ondrej
    Gnap, Jozef
    Caban, Jacek
    TRANSBALTICA 2017: TRANSPORTATION SCIENCE AND TECHNOLOGY, 2017, 187 : 775 - 782
  • [5] The Experimental Investigation of the Effects of Operating Parameters on Exhaust Emissions on a Spark Ignition Engine
    Topgul, Tolga
    Yucesu, Huseyin Serdar
    Okur, Melih
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2005, 8 (01): : 43 - 47
  • [6] Review on performance and emission of spark ignition engine using exhaust gas recirculation
    Pardhi, Chandrakumar
    Prasad, Rabindra
    Jawahar, C. P.
    Chhalotre, Sanjay
    Said, Zafar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (02) : 3692 - 3707
  • [7] EXPERIMENTAL INVESTIGATION OF AN IMPROVED EXHAUST RECOVERY SYSTEM FOR LIQUID PETROLEUM GAS FUELED SPARK IGNITION ENGINE
    Gurbuz, Habib
    Akcay, Husameddin
    THERMAL SCIENCE, 2015, 19 (06): : 2049 - 2064
  • [8] Effect of Preheating on Firing Behavior of a Spark-Ignition Methanol-Fueled Engine during Cold Start
    Li, Jun
    Gong, Changming
    Su, Yan
    Dou, Huili
    Liu, Xunjun
    ENERGY & FUELS, 2009, 23 (11) : 5394 - 5400
  • [9] Investigation of critical firing boundary of spark ignition methanol engine during cold start
    Gong C.-M.
    Li Z.-H.
    Qu X.
    Liu F.-H.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2016, 46 (04): : 1118 - 1123
  • [10] CFD AND EXPERIMENTAL ANALYSIS ON THERMAL PERFORMANCE OF EXHAUST SYSTEM OF A SPARK IGNITION ENGINE
    Durat, Mesut
    Parlak, Zekeriya
    Kapsiz, Murat
    Parlak, Adnan
    Ficici, Ferit
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2013, 33 (02) : 89 - 99