Faulted line detection is a key step of intelligent fault diagnosis of distribution systems, laying the foundation for the further fault location and service restoration. A novel single line-to-ground (SLG) faulted line detection method based on the feature fusion framework is proposed. In the proposed framework, one dimensional Convolutional Neural Network is employed as a powerful tool to extract more effective features. In addition, there is an imbalance phenomenon between data of the faulted line and healthy lines when a data-driven model is used in the faulted line detection. The proposed framework offers an avenue for overcoming it and improves the accuracy of detection. Considering the limited data of SLG faults in actual power systems, prior knowledge of SLG fault detection is integrated into the data-driven model, which proves useful in reducing dependency on the training data quantity. The experiments verified the superior performance of the proposed feature fusion framework based method.
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Single Line-to-Ground Faulted Line Detection of Distribution Systems With Resonant Grounding Based on Feature Fusion Framework
    Du, Ying
    Liu, Yadong
    Shao, Qingzhu
    Luo, Lingen
    Dai, Jindun
    Sheng, Gehao
    Jiang, Xiuchen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1766 - 1775
  • [2] Suppression Strategy on Neutral Point Overvoltage in Resonant Grounding System Considering Single Line-to-ground Fault
    Wang, Hui
    Guo, Moufa
    Zheng, Zeyin
    Cai, Wenqiang
    Tang, Jie
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 206
  • [3] Faulted feeder identification and location for a single line-to-ground fault in ungrounded distribution system based on principal frequency component
    Liu, Ling
    ARCHIVES OF ELECTRICAL ENGINEERING, 2020, 69 (03) : 695 - 704
  • [4] Single line-to-ground fault location based on unsynchronized phasors in automated ungrounded distribution systems
    Nam, Soon-Ryul
    Kang, Sang-Hee
    Ahn, Seon-Ju
    Choi, Joon-Ho
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 86 : 151 - 157
  • [5] High resistance single-phase grounding line selection in resonant grounding systems based on correlation detection
    Liu J.
    Chen X.
    Zhang Z.
    Li
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (01): : 63 - 70
  • [6] A Novel Automatic Detection Model for Single Line-to-ground Fault
    Sun Z.
    Lv G.
    Luo Z.
    Xie C.
    Wang W.
    Journal Europeen des Systemes Automatises, 2019, 52 (03): : 229 - 233
  • [7] Line selection method for grounding fault in resonant grounding distribution systems
    Long R.
    Huang C.
    Tang T.
    Zeng J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (21): : 21 - 29
  • [8] Resonance mechanisms of a single line-to-ground fault on ungrounded systems
    Jiang, Jun
    Liu, Ling
    ARCHIVES OF ELECTRICAL ENGINEERING, 2020, 69 (02) : 455 - 466
  • [9] A Study on the Detection of Single line-to-ground fault in High Resistance Grounding System using Convolutional Neural Network
    Hwang D.-J.
    Kim C.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (09): : 987 - 993
  • [10] A composite ground faulted line detection device in small current neutral grounding network
    Zhongshan Polytechnic, Zhongshan 528404, China
    Gaoya Dianqi, 2007, 4 (298-300+303):