Assessment of Corneal Pachymetry Distribution and Morphologic Changes in Subclinical Keratoconus with Normal Biomechanics

被引:14
|
作者
Song, Peng [1 ,2 ,3 ]
Yang, Kaili [4 ]
Li, Pei [1 ]
Liu, Yu [1 ]
Liang, Dengfeng [1 ]
Ren, Shengwei [4 ]
Zeng, Qingyan [1 ,2 ,3 ]
机构
[1] Cent South Univ, Aier Sch Ophthalmol, Changsha, Hunan, Peoples R China
[2] Hankou Aier Eye Hosp, Wuhan, Hubei, Peoples R China
[3] Wuhan Aier Eye Inst, Wuhan, Hubei, Peoples R China
[4] Zhengzhou Univ, Peoples Hosp, Henan Eye Inst, Henan Prov Peoples Hosp,Henan Eye Hosp, Zhengzhou, Henan, Peoples R China
关键词
FELLOW EYES; TOMOGRAPHY; PARAMETERS; ECTASIA; ELEVATION; INDEX;
D O I
10.1155/2019/1748579
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To investigate the pachymetry distribution of central cornea and morphologic changes in subclinical keratoconus with normal biomechanics and determine their potential benefit for the screening of very early keratoconus. Methods. This retrospective comparative study was performed in 33 clinically unaffected eyes with normal topography and biomechanics from 33 keratoconus patients with very asymmetric ectasia (VAE-NTB; Corvis Biomechanical Index defined) and 70 truly normal eyes from 70 age-matched subjects. Corneal topographic, tomographic, and biomechanical metrics were measured using Pentacam and Corvis ST. The distance and pachymetry difference between the corneal thinnest point and the apex were defined as DTCP-Apex and DPTCP-Apex, respectively, to evaluate the pachymetry distribution within the central cornea. The discriminatory power of metrics was analysed via the receiver operating characteristic curve. A logistic regression analysis was used to establish predictive models. Results. The parameters, DTCP-Apex and DPTCP-Apex, were significantly higher in VAE-NTB than those in normal eyes. For differentiating normal and VAE-NTB eyes, the Belin-Ambrosio deviation (BAD-D) showed the largest area under the curve (AUC; 0.799), followed by ARTmax (0.798), DTCP-Apex (0.771), tomography and biomechanical index (0.760), maximum pachymetry progression index (PPImax, 0.756), DPTCP-Apex (0.753), and back eccentricity (B_Ecc, 0.707) with no statistically significant differences among these AUCs. In the VAE-NTB group, the parameter B_Ecc was significantly and positively correlated with DTCP-Apex (P=0.011) and DPTCP-Apex (P=0.035), whereas the posterior elevation difference had a significant positive association with DPTCP-Apex (P=0.042). A model using the indices DTCP-Apex, B_Ecc, PPImax, and index of height asymmetry demonstrated the highest AUC of 0.846 with 91.43% specificity. Conclusions. Abnormal pachymetry distribution within the central cornea and subtle morphologic changes are detectable in subclinical keratoconus with normal biomechanics. This may improve VAE-NTB eyes detection.
引用
收藏
页数:7
相关论文
共 34 条
  • [1] Corneal biomechanics in normal and subclinical keratoconus eyes
    Peyman, Alireza
    Sepahvand, Fatemeh
    Pourazizi, Mohsen
    Noorshargh, Pegah
    Forouhari, Ali
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [2] Corneal biomechanics in normal and subclinical keratoconus eyes
    Alireza Peyman
    Fatemeh Sepahvand
    Mohsen Pourazizi
    Pegah Noorshargh
    Ali Forouhari
    BMC Ophthalmology, 23
  • [3] Changes of Corneal Biomechanics With Keratoconus
    Wolffsohn, James S.
    Safeen, Saima
    Shah, Sunil
    Laiquzzaman, Mohammad
    CORNEA, 2012, 31 (08) : 849 - 854
  • [4] Evaluation of corneal topography, pachymetry and higher order aberrations for detecting subclinical keratoconus
    Kandel, Sandeep
    Chaudhary, Meenu
    Mishra, Sanjeeb K.
    Joshi, Niraj D.
    Subedi, Manish
    Puri, Prajjol R.
    Gyawali, Parash
    Bist, Jeewanand
    Kandel, Himal
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2022, 42 (03) : 594 - 608
  • [5] Morphologic Corneal Changes after Crosslinking for Keratoconus
    Mueller, P. L.
    Loeffler, K. U.
    Kohlhaas, M.
    Holz, F. G.
    Herwig-Carl, M. C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (07) : 809 - 819
  • [6] Assessment of corneal biomechanics, tonometry and pachymetry with the Corvis ST in myopia
    Wang, Xiaorui
    McAlinden, Colm
    Zhang, Hongbing
    Yan, Jie
    Wang, Dan
    Wei, Wei
    Mi, Shengjian
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus
    Pinero, David P.
    Alio, Jorge L.
    Aleson, Alicia
    Escaf Vergara, Munir
    Miranda, Mauricio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 814 - 825
  • [8] Assessment of corneal biomechanics, tonometry and pachymetry with the Corvis ST in myopia
    Xiaorui Wang
    Colm McAlinden
    Hongbing Zhang
    Jie Yan
    Dan Wang
    Wei Wei
    Shengjian Mi
    Scientific Reports, 11
  • [9] Changes in Corneal Biomechanics in Patients With Keratoconus After Penetrating Keratoplasty
    Yenerel, Nursal Melda
    Kucumen, Raciha Beril
    Gorgun, Ebru
    CORNEA, 2010, 29 (11) : 1247 - 1251
  • [10] Dynamic corneal biomechanics in different cell layers: in keratoconus and normal eyes
    Alvani, Azam
    Hashemi, Hassan
    Pakravan, Mohammad
    Mahbod, Mirgholamreza
    Amanzadeh, Kazem
    Seyedian, Mohammad Amin
    Yaseri, Mehdi
    Jafarzadehpur, Ebrahim
    Fotouhi, Akbar
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2021, 41 (02) : 414 - 423