Joint TNT and RDX detection via quadrupole resonance

被引:12
|
作者
Xiong, Hong [1 ]
Li, Jian [1 ]
Barrall, Geoffrey A. [2 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[2] Quantum Magnet Inc, San Diego, CA 92128 USA
基金
美国国家科学基金会;
关键词
D O I
10.1109/TAES.2007.4441739
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Quadrupole resonance (QR) technology has been receiving increasing attention for explosive detection in applications including landmine detection. It can be used as a confirming sensor for buried plastic landmine detection by detecting the explosives within the mine. Since a single mine can contain more than one type of explosives (e.g., trinitrotoluene (TNT) and Royal Demolition eXplosive (RDX) compound), a detector designed to detect only one type of explosive may not provide the best detection. We focus herein on the joint detection of TNT and RDX explosives for the landmine detection via the QR sensor. To mitigate the RF interferences (RFIs) associated with the QR measurements, we apply a doubly constrained robust Capon beamformer (DCRCB) to perform the spatial beamforming by exploiting the spatial correlation of the RFIs. Based on the output of the spatial DCRCB, we devise a generalized likelihood ratio test (GLRT) for the joint TNT/RDX detection, which is referred to as the DCRCB-GLRT detector. We show that our detector has the constant false alarm rate (CFAR) property and that the detection variable obeys a chi(2)-mixture distribution in the mine-free scenario. The effectiveness of the proposed DCRCB-GLRT detector is demonstrated with the experimental data collected by Quantum Magnetics, Inc.
引用
收藏
页码:1282 / 1293
页数:12
相关论文
共 50 条
  • [1] The detection of RDX and TNT mine like targets by nuclear quadrupole resonance
    Deas, RM
    Burch, IA
    Port, DM
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS VII, PTS 1 AND 2, 2002, 4742 : 482 - 489
  • [2] Detection of TNT and RDX landmines by stand-off nuclear quadrupole resonance
    Hibbs, AD
    Barrall, GA
    Czipott, PV
    Drew, AJ
    Gregory, D
    Lathrop, DK
    Lee, YK
    Magnuson, EE
    Matthews, R
    Skvoretz, DC
    Vierkötter, SA
    Walsh, DO
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS IV, PTS 1 AND 2, 1999, 3710 : 454 - 463
  • [3] Nuclear quadrupole resonance of explosives: Simultaneous detection of RDX and PETN in semtex
    R. I. Jenkinson
    J. M. Bradley
    G. N. Shilstone
    Applied Magnetic Resonance, 2004, 25 : 439 - 448
  • [4] Nuclear quadrupole resonance of explosives: Simultaneous detection of RDX and PETN in semtex
    Jenkinson, RI
    Bradley, JM
    Shilstone, GN
    APPLIED MAGNETIC RESONANCE, 2004, 25 (3-4) : 439 - 448
  • [5] Use of multi-pulse nuclear quadrupole resonance techniques for the detection of explosives containing RDX
    Kaliningrad State Univ, Kaliningrad, Russia
    J Phys D, 9 (1377-1382):
  • [6] The use of multi-pulse nuclear quadrupole resonance techniques for the detection of explosives containing RDX
    Rudakov, TN
    Mikhaltsevich, VT
    Selchikhin, OP
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (09) : 1377 - 1382
  • [7] SOFT LIBRATIONAL MODE DETECTION VIA NUCLEAR QUADRUPOLE RESONANCE
    OLEARY, GP
    PHYSICAL REVIEW LETTERS, 1969, 23 (14) : 782 - &
  • [8] Gas-phase reactions for selective detection of the explosives TNT and RDX
    Meurer, EC
    Chen, H
    Riter, L
    Cotte-Rodriguez, I
    Eberlin, MN
    Cooks, RG
    CHEMICAL COMMUNICATIONS, 2004, (01) : 40 - 41
  • [10] A METHOD FOR DETERMINING RDX EXPOSURE IN AN ATMOSPHERE CONTAINING RDX AND TNT
    MCGEE, WA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1968, 29 (02): : 104 - &