Combined measurement of PEMFC performance decay and water droplet distribution under low humidity and high CO

被引:13
|
作者
Murahashi, Toshiaki [1 ]
Kobayashi, Hiroyuki [1 ]
Nishiyama, Enju [1 ]
机构
[1] Fukui Univ Technol, Dept Elect & Elect Engn, Fukui 9108505, Japan
关键词
PEMFC; degradation; visualization; CO poisoning; water droplet;
D O I
10.1016/j.jpowsour.2007.09.038
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Measurements of the performance decay for a proton exchange membrane fuel cell (PEMFC) and the observation of water droplets were simultaneously carried out for 4000 h under degradation conditions of low humidity and high CO concentration. An optical cell was designed for observation of water droplets and measurement of the transition points. It was found that as the performance decayed with time, the transition point to a two-phase flow moved toward the cathode exit for conditions of both low humidity and high CO concentration. Performance data showed that under these conditions, there was no pinhole in the membrane or significant mass transport loss observed. It was supposed that the deactivation of electrodes occurred at the cathode inlet and the anode outlet under low humidity and high CO concentration, and that this caused the decay in performance and observed change of the transition point at the cathode. The change of the transition point was computed using a two-dimensional cell model. Performance decay, such as oxygen gain and the cell over-potential, was simulated by changing the value of the exchange current densities of the cathode and anode. Comparison with the experimental results shows good agreement for the total duration of cell operation. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 50 条
  • [1] MEASUREMENT OF WATER DISTRIBUTION IN ANODE OF POLYMER ELECTROLYTE FUEL CELL UNDER LOW HUMIDITY CONDITIONS
    Nishida, Kosuke
    Yokoi, Yohma
    Tsushima, Shohji
    Hirai, Shuichiro
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY, 2009, : 121 - 127
  • [2] Progress of Highly Durable MEA for PEMFC Under High Temperature and Low Humidity Conditions
    Endoh, Eiji
    FUEL CELL SEMINAR 2007, 2008, 12 (01): : 41 - 50
  • [3] Combined effects of Pt/C ratio and relative humidity on the performance and gas distribution quality of PEMFC with graded ionomer distribution
    Ding, Rui
    Cheng, Youliang
    Fan, Xiaochao
    Wang, Naixiao
    Zhang, Lei
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 79 : 208 - 220
  • [4] Development of Highly Durable PFSA Membrane for PEMFC Under High Temperature and Low Humidity Conditions
    Endoh, Eiji
    BATTERY/ENERGY TECHNOLOGY (GENERAL) - 216TH ECS MEETING, 2010, 25 (35): : 293 - 307
  • [5] Investigations on PEMFC Performance Under High Current Density and Low Humidification
    Fan, Lin-Hao
    Zhang, Guo-Bin
    Jiao, Kui
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2019, 40 (04): : 870 - 876
  • [6] Development of Highly Durable PFSA Membrane and MEA for PEMFC Under High Temperature and Low Humidity Conditions
    Endoh, Eiji
    PROTON EXCHANGE MEMBRANE FUEL CELLS 8, PTS 1 AND 2, 2008, 16 (02): : 1229 - 1240
  • [7] Water management issues during load cycling under high temperature and low humidity conditions relevant for heavy-duty applications of PEMFC
    Shao, Yangbin
    Xu, Liangfei
    Xu, Ling
    Zhang, Xiyuan
    Wang, Zhina
    Zhao, Guanlei
    Hu, Zunyan
    Li, Jianqiu
    Ouyang, Minggao
    ETRANSPORTATION, 2023, 18
  • [8] Separation Analysis of Electro-Osmosis and Diffusion of Water in Electrolyte Membrane of PEMFC under Low-Humidity Operation
    Nishida, K.
    Hosotani, T.
    Asa, M.
    Tsushima, S.
    Hirai, S.
    POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 621 - 630
  • [9] Study on the Alleviation of Performance Degradation and Voltage Stability of PEMFC by Adding Silica Under Low-Temperature and Low-Humidity Conditions
    Bai, Qiang
    Hsieh, Chuangyu
    Liu, Zhenghong
    Chen, Qipeng
    Weng, Fangbor
    CRYSTALS, 2024, 14 (12)
  • [10] Influence of Triple MPL Coated GDL on the PEFC Performance under Low and High Humidity
    Kitahara, T.
    Nakajima, H.
    Inamoto, M.
    Shinto, K.
    POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 1401 - 1408