Performance evaluation of the PET component of a hybrid PET/CT-ultrafast ultrasound imaging instrument
被引:8
|
作者:
Perez-Liva, Mailyn
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Perez-Liva, Mailyn
[1
]
Viel, Thomas
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Univ Paris 05, Fac Med, Sorbonne Paris Cite, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Viel, Thomas
[1
,2
]
Yoganathan, Thulaciga
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Univ Paris 05, Fac Med, Sorbonne Paris Cite, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Yoganathan, Thulaciga
[1
,2
]
Garofalakis, Anildtos
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Garofalakis, Anildtos
[1
]
Sourdon, Joevin
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Sourdon, Joevin
[1
]
Facchin, Caterina
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Facchin, Caterina
[1
]
Tanter, Mickael
论文数: 0引用数: 0
h-index: 0
机构:
Paris Sci & Letters Res Univ, Ecole Super Phys & Chim Ind, Technol Res Accelerator Biomed Ultrasound, CNRS,UMR 7587,Inserm,U979,Inst Langevin, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Tanter, Mickael
[3
]
Provost, Jean
论文数: 0引用数: 0
h-index: 0
机构:
Paris Sci & Letters Res Univ, Ecole Super Phys & Chim Ind, Technol Res Accelerator Biomed Ultrasound, CNRS,UMR 7587,Inserm,U979,Inst Langevin, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Provost, Jean
[3
]
Tavitian, Bertrand
论文数: 0引用数: 0
h-index: 0
机构:
Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Univ Paris 05, Fac Med, Sorbonne Paris Cite, Paris, FranceInserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
Tavitian, Bertrand
[1
,2
]
机构:
[1] Inserm, Paris Cardiovasc Res Ctr, UMR970, Paris, France
[2] Univ Paris 05, Fac Med, Sorbonne Paris Cite, Paris, France
[3] Paris Sci & Letters Res Univ, Ecole Super Phys & Chim Ind, Technol Res Accelerator Biomed Ultrasound, CNRS,UMR 7587,Inserm,U979,Inst Langevin, Paris, France
NEMA protocol;
hybrid imaging systems;
ultrafast ultrasound imaging;
PET imaging;
ultrasound probe inside a PET gantry;
ARTIFACTS;
D O I:
10.1088/1361-6560/aad946
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
We recently introduced a hybrid imaging instrument, PETRUS, based on a combination of positron emission tomography (PET) for molecular imaging, x-ray computed tomography (CT) for anatomical imaging, co-registration and attenuation correction, and ultrafast ultrasound imaging (UUI) for motion-correction, hemodynamic and biomechanical imaging. In order to ensure a precise co-registration of simultaneous PET-UUI acquisitions, ultrasound probes attached to an ultrafast ultrasound scanner are operated in the field of view (FOV) of a small animal PET/CT scanner using a remote-controlled micro-positioner. Here we explore the effect of the presence of ultrasound probes on PET image quality. We compare the performance of PET and image quality with and without the presence of probes in the PET field of view, both in vitro following the NEMA-NU-4-2008 standard protocol, and in vivo in small animals. Overall, deviations in the quality of images acquired with and without the ultrasound probes were under 10% and under 7% for the NEMA protocol and in vivo tests, respectively. Our results demonstrate the capability of the PETRUS device to acquire multimodal images in vivo without significant degradation of image quality.