Preparation of an anion stationary phase modified by quaternary ammoniated allyl glycidyl ether

被引:0
|
作者
Li Zongying [1 ]
Chen Xin [1 ]
Zhang Feifang [1 ]
Yang Bingcheng [1 ]
机构
[1] East China Univ Sci & Technol, Sch Pharm, Shanghai 200237, Peoples R China
关键词
ion chromatography (IC); poly (glycidylmethacrylate-divinylbenzene) (GMA-DVB); pedant double bonds; stationary phase; EXCHANGE SELECTIVITY; ION CHROMATOGRAPHY; POLYETHYLENEIMINE; PERFORMANCE;
D O I
10.3724/SP.J.1123.2022.03008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polymer-based strong anion stationary phase modified by quaternary ammoniated allyl glycidyl ether (AGE) for ion chromatography (IC) was developed. It was prepared by surface copolymerization between AGE and the pedant double bonds associated with hydrolyzed poly(glycidylmethacrylate-divinylbenzene) (GMA-DVB) substrate , followed by quaternization with N,N-methyldiethanolamine (a tertiary amine, MDEA). The synthesis conditions were optimized, including the type of organic tertiary amines (MDEA, N,N-dimethylethanolamine , trimethylamine) , substrate hydrolysis , the amount of monomer and initiator, reaction temperature and reaction time. The obtained anion stationary phase was characterized by scanning electron microscope and elemental analysis. MDEA was observed to be the best quaternization reagent since the anion exchanger obtained by such reagent showed good separation and suitable retention time towards model inorganic anions. The resulting reason probably lies in higher hydrophilicity of MDEA relative the other two ones. The use of rich epoxy groups of GMA-DVB to introduce the functional groups was commonly used in many previous reports. Here the epoxy groups were firstly hydrolyzed to be diol groups and the pendant double bonds onto the surface of GMA-DVB particles were used to graft AGE. The data achieved indicated that the use of hydrolyzed GMA-DVB substrate would be helpful to reduce anion exchange capacity and unwanted non-ion exchange interaction , in which the rich epoxy groups were converted to hydroxy groups. More important, the obtained anion exchanger after hydrolytic treatment could offer a significantly reduction of retention time (similar to 68%) and a similar to 1. 67-fold higher plate count (take Br- as an example). The apparent capacity of the phase was computed to be 264 mu mol/g by content of N data and its effective capacity was measured to be 98. 5 mu mol/column by the breakthrough curve method. Under the optimal chromatographic conditions, the obtained stationary phase showed baseline separation of seven common inorganic anions in less than 13 min using carbonate-bicarbonate mixed eluent, exhibiting high separation efficiency and peak shape, e. g. 49 000 plate/m and 38 000 plate/m of the theoretical plate counts respectively for chloride and nitrate, and their asymmetric factor were 1. 3 and 1. 4. These can be comparable or slightly higher than those of commercial columns. The fitted equation of the eluent concentration and the retention factors of model anions was proved that ion exchange model dominates the retention mechanism of the anion stationary phase. This offers a simple way to prepare anion exchanger and to manipulate anion exchange capacity. The utility of the obtained anion exchanger has been demonstrated to the analysis of tap water.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 16 条
  • [1] The polystyrene-divinylbenzene stationary phase modified with poly (Amine-Epichlorohydrin) for ion chromatography
    Huang, Zhongping
    Zhuge, Chun
    Zhu, Qiulian
    Liu, Huijun
    She, Yuanbin
    Zhu, Yan
    [J]. MICROCHEMICAL JOURNAL, 2020, 155
  • [2] Thiol and disulfide addition to the pendant vinylbenzene groups of poly(divinylbenzene-co-ethylvinylbenzene including Amberlite XAD-4
    Hubbard, KL
    Finch, JA
    Darling, GD
    [J]. REACTIVE & FUNCTIONAL POLYMERS, 1999, 40 (01): : 61 - 90
  • [3] Verification of Core/Shell Structure of Poly(glycidyl methacrylate-co-divinyl benzene) Microspheres
    Jin, Jeongmin
    Choi, Jin Young
    Lee, Kangseok
    Choe, Soonja
    [J]. MACROMOLECULAR RESEARCH, 2009, 17 (05) : 339 - 345
  • [4] Investigations on the selectivity of grafted high performance anion exchangers and the underlying graft mechanism
    Kaltz, Achim
    Bohra, Lea
    Tripp, Jonathan S.
    Seubert, Andreas
    [J]. ANALYTICA CHIMICA ACTA, 2018, 999 : 176 - 183
  • [5] A polymer-based zwitterionic stationary phase for hydrophilic interaction chromatography
    Li, Shuxiang
    Li, Zongying
    Zhang, Feifang
    Geng, Huiliang
    Yang, Bingcheng
    [J]. TALANTA, 2020, 216
  • [6] Octadecylamine-modified poly (glycidylmethacrylate-divinylbenzene) stationary phase for HPLC determination of N-nitrosamines
    Liu, Junwei
    Wang, Yong
    Li, Weixia
    Zhang, Peimin
    Wang, Nani
    Wu, Shuchao
    Zhu, Yan
    [J]. TALANTA, 2016, 160 : 298 - 305
  • [7] High-capacity anion exchangers based on poly (glycidylmethacrylate-divinylbenzene) microspheres for ion chromatography
    Liu, Junwei
    Wang, Yong
    Cheng, Heli
    Wang, Nani
    Wu, Shuchao
    Zhang, Peimin
    Zhu, Yan
    [J]. TALANTA, 2016, 159 : 272 - 279
  • [8] Silica based click amino stationary phase for ion chromatography and hydrophilic interaction liquid chromatography
    Liu, Yajing
    Du, Qing
    Yang, Bingcheng
    Zhang, Feifang
    Chu, Changhu
    Liang, Xinmiao
    [J]. ANALYST, 2012, 137 (07) : 1624 - 1628
  • [9] Factors controlling ion-exchange selectivity in suppressed ion chromatography
    Pohl, CA
    Stillian, JR
    Jackson, PE
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) : 29 - 41
  • [10] Novel polymer-based anion-exchangers with covalently-bonded functional layers of quaternized polyethyleneimine for ion chromatography
    Shchukina, O. I.
    Zatirakha, A. V.
    Uzhel, A. S.
    Smolenkov, A. D.
    Shpigun, O. A.
    [J]. ANALYTICA CHIMICA ACTA, 2017, 964 : 187 - 194