Surgical Treatment of Adult Extra-Articular Distal Humeral Diaphyseal Fractures Using an Oblique Metaphyseal Locking Compression Plate via a Posterior Approach

被引:13
|
作者
Yang, Qing [1 ]
Wang, Fang [1 ]
Wang, Qiugen [1 ]
Gao, Wei [1 ]
Huang, Jianhua [1 ]
Wu, Xiaofeng [1 ]
Wu, Jiaqi [1 ]
Chen, Hao [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthoped Surg, Coll Med, Shanghai Peoples Hosp 1, Shanghai 200080, Peoples R China
关键词
Distal humeral fracture; Open reduction and internal fixation; Fixation; Locking compression plates; Osteosynthesis; Complication; SHAFT FRACTURES; FIXATION; OSTEOSYNTHESIS; NERVE; 3RD;
D O I
10.1159/000331791
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The purpose of this study was to evaluate the feasibility and clinical outcome of using an oblique AO (Association for the Study of Internal Fixation) metaphyseal locking compression plate (MLCP) in the treatment of adult extra-articular distal humeral diaphyseal fractures via a posterior approach. Subjects and Methods: A series of 19 cases of adult extra-articular distal humeral diaphyseal fractures were surgically treated using an MLCP and lag screws, if necessary, via a posterior approach. All patients were followed for a mean time of 16.6 months (range from 12 to 20 months). The patients were followed up to 1 year, and radiological assessment was performed to observe fracture reduction and healing. Functional outcome was measured including the range of motion of the shoulder and elbow, by the University of California at Los Angeles and the Mayo Elbow Performance Score. Results: The incidence of iatrogenic radial nerve palsy was 5%. There was no failure of internal fixation and no infection. After 1 year, the University of California at Los Angeles scoring system rated 12 (63.2%) patients as excellent results. The Mayo elbow performance scoring system rated 10 (84%) cases as excellent results. Completely normal alignment was presented in 16 cases. Conclusion: Following surgical treatment of adult extra-articular distal humeral diaphyseal fractures, an oblique MLCP applied via a posterior approach achieved an adequate internal fixation and obtained an excellent functional outcome. Copyright (C) 2011 S. Karger AG, Basel
引用
收藏
页码:40 / 45
页数:6
相关论文
共 50 条
  • [1] Single locking compression plate fixation of extra-articular distal humeral fractures
    Kumar M.N.
    Ravishankar M.R.
    Manur R.
    Journal of Orthopaedics and Traumatology, 2015, 16 (2) : 99 - 104
  • [2] Biomechanical evaluation of a modified proximal humeral locking plate application for distal extra-articular diaphyseal humeral fractures
    Lim, Joon-Ryul
    Yoon, Tae-Hwan
    Choi, Yun-Rak
    Lee, Hwan-Mo
    Chun, Yong-Min
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (09) : 1877 - 1883
  • [3] Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures
    Sohn, Hoon-Sang
    Shin, Sang-Jin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (07): : 1300 - 1305
  • [4] Comparison of lateral and posterior surgical approach in management of extra-articular distal humeral shaft fractures
    Yin, Peng
    Zhang, Lihai
    Mao, Zhi
    Zhao, Yanpeng
    Zhang, Qun
    Tao, Sheng
    Liang, Xiangdang
    Zhang, Hao
    Lv, Houchen
    Li, Tongtong
    Tang, Peifu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (07): : 1121 - 1125
  • [5] Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures
    Shin, Sang-Jin
    Kwak, Ji-Woong
    Sohn, Hoon-Sang
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (09) : 2119 - 2126
  • [6] Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures
    Sang-Jin Shin
    Ji-Woong Kwak
    Hoon-Sang Sohn
    International Orthopaedics, 2022, 46 : 2119 - 2126
  • [7] Analyzing the modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures with some concerns
    Bansal, Hemant
    Mittal, Samarth
    Gupta, Anupam
    Trikha, Vivek
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (08): : 1938 - 1938
  • [8] Fixation of extra-articular distal humeral fractures with a lateral approach and a locked plate: an alternative method
    Parmaksizoglu, Atilla Sancar
    Ozkaya, Ufuk
    Bilgili, Fuat
    Mutlu, Harun
    Cetin, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (02) : 132 - 138
  • [9] A NEW ANATOMICAL PLATE FOR EXTRA-ARTICULAR DISTAL HUMERAL FRACTURES: BIOMECHANICAL STUDY
    Mutlu, Harun
    Polat, Abdulkadir
    Cetin, Mehmet Umit
    Mutlu, Serhat
    Demir, Teyfik
    Parmaksizoglu, Atilla Sancar
    ACTA ORTOPEDICA BRASILEIRA, 2022, 30 (01):
  • [10] Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
    Tarallo L.
    Mugnai R.
    Adani R.
    Catani F.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 285 - 290