Indications for transvenous lead extraction and its procedural and early outcomes in elderly patients: a single-center experience

被引:3
|
作者
Zabek, Andrzej [1 ]
Boczar, Krzysztof [1 ]
Debskil, Maciej [1 ]
Pfitzner, Roman [2 ,3 ]
Ulmanl, Mateusz [1 ]
Holcman, Katarzyna [2 ,4 ]
Kostkiewicz, Magdalena [2 ,4 ]
Musial, Robert [5 ]
Lelakowski, Jacek [1 ,2 ]
Malecka, Barbara [1 ,2 ]
机构
[1] John Paul 2 Hosp, Dept Electrocardiol, Ul Pradnicka 80, PL-31202 Krakow, Poland
[2] Jagiellonian Univ, Inst Cardiol, Med Coll, Krakow, Poland
[3] John Paul 2 Hosp, Dept Cardiovasc Surg, Krakow, Poland
[4] John Paul 2 Hosp, Dept Cardiac & Vasc Dis, Krakow, Poland
[5] John Paul 2 Hosp, Dept Anesthesiol & Intens Therapy, Krakow, Poland
关键词
cardiovascular implantable electronic devices; effectiveness; elderly; safety; transvenous lead extraction; PREDICTORS; MORTALITY; DEFIBRILLATOR; PACEMAKER; REGISTRY; SAFETY; 30-DAY; OLDER;
D O I
10.20452/pamw.15182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION Due to the prolonged survival of patients with cardiovascular implantable electronic devices, leads often need to be removed in elderly individuals. OBJECTIVES We aimed to analyze indications for transvenous lead extraction (TLE), procedure effectiveness and safety, as well as 30-day follow-up in younger patients (<= 80 years) and octogenarians (>80 years). PATIENTS AND METHODS This prospective study included 667 patients who underwent TLE: 90 octogenarians (13.5%) at a mean age of 83.8 (range, 80.4-93) years and 577 younger patients (86.5%) at a mean age of 64.2 (range, 18.9-79.9) years. RESULTS Octogenarians had a greater number of comorbidities, fewer implantable cardioverter-defibrillators implanted, and more frequently had infection as an indication for TLE, as compared with younger patients (33.3% vs 17.1%; P <0.001). In octogenarians, 138 leads were extracted, as compared with 894 leads in younger patients. Octogenarians and younger patients had similar rates of complete lead removal (98.6% and 97.1%, respectively; P = 0.48), total procedural success (97.8% and 96%, respectively; P = 0.7), major complications (0% and 1.6%, respectively; P = 0.45), and minor complications (2.2% and 1.6%, respectively; P = 0.45). There was 1 death associated with TLE in younger patients. Non-procedure-related deaths within 30 days after TLE were more frequent in octogenarians than in younger patients (5.6% vs 1.9%; P = 0.04). CONCLUSIONS We showed that TLE in patients older than 80 years seems to be as effective as in younger patients; however, it is associated with significantly higher non-procedure-related 30-day mortality.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
  • [1] Outcomes of transvenous lead extraction in patients with lead perforation: A single-center experience
    Zhou, Xu
    Ze, Feng
    Li, Ding
    Wang, Long
    Guo, Jihong
    Li, Xuebin
    CLINICAL CARDIOLOGY, 2020, 43 (04) : 386 - 393
  • [2] Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications
    Jones, Samuel O.
    Eckart, Robert E.
    Albert, Christine M.
    Epstein, Laurence M.
    HEART RHYTHM, 2008, 5 (04) : 520 - 525
  • [3] Large, Single-Center Experience in Transvenous Coronary Sinus Lead Extraction: Procedural Outcomes and Predictors for Mechanical Dilatation
    Di Cori, Andrea
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    Segreti, Luca
    Viani, Stefano
    De Lucia, Raffaele
    Paperini, Luca
    Soldati, Ezio
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (02): : 215 - 222
  • [4] The complications of lead extraction with infected vegetations: a single-center experience and consequences of transvenous extraction
    Nagashima, M.
    Goya, M.
    Soga, Y.
    Hiroshima, K.
    Andou, K.
    Iwabuchi, M.
    Yokoi, H.
    Nobuyoshi, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 796 - 796
  • [5] Strategies and outcomes of patients with severely reduced ejection fraction (≤15%) undergoing transvenous lead extraction: A single-center experience
    Arora, Yingyot
    Llaneras, Noah
    Carrillo, Roger
    HEART RHYTHM, 2022, 19 (12) : 2002 - 2008
  • [6] Safety and Efficacy of Transvenous Lead Extraction Utilizing the Evolution Mechanical Lead Extraction System A Single-Center Experience
    Sharma, Saumya
    Ekeruo, Ijeoma A.
    Nand, Nikita P.
    Raman, Ajay Sundara
    Zhang, Xu
    Reddy, Sunil K.
    Hariharan, Ramesh
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (02) : 212 - 220
  • [7] Safe and effective transvenous lead extraction for elderly patients utilizing non-laser and laser tools: a single-center experience in Japan
    Ayako Okada
    Hiroaki Tabata
    Morio Shoda
    Wataru Shoin
    Hideki Kobayashi
    Takahiro Okano
    Koji Yoshie
    Ken Kato
    Tatsuya Saigusa
    Soichiro Ebisawa
    Hirohiko Motoki
    Koichiro Kuwahara
    Heart and Vessels, 2021, 36 : 882 - 889
  • [8] Safe and effective transvenous lead extraction for elderly patients utilizing non-laser and laser tools: a single-center experience in Japan
    Okada, Ayako
    Tabata, Hiroaki
    Shoda, Morio
    Shoin, Wataru
    Kobayashi, Hideki
    Okano, Takahiro
    Yoshie, Koji
    Kato, Ken
    Saigusa, Tatsuya
    Ebisawa, Soichiro
    Motoki, Hirohiko
    Kuwahara, Koichiro
    HEART AND VESSELS, 2021, 36 (06) : 882 - 889
  • [9] Transvenous Pacemaker and Defibrillator Lead Extraction in the Setting of Noninfectious Indications: A Large, Single Center Experience
    Mahoney, Timothy H.
    Alves, Carlos
    Wazni, Ousamma
    Martin, David O.
    Saliba, Walid
    Niebauer, Mark
    Varma, Niraj
    Callahan, Thomas
    Kanj, Mohamed
    Wilkoff, Bruce L.
    CIRCULATION, 2009, 120 (18) : S714 - S714
  • [10] Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience
    Federico Migliore
    Raimondo Pittorru
    Manuel De Lazzari
    Vincenzo Tarzia
    Gianni Pastore
    Lina Marcantoni
    Domenico Catanzariti
    Gino Gerosa
    Francesco Zanon
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 175 - 182