A European survey on the regulatory status for the estimation of the effective dose and the equivalent dose to the lens of the eye when radiation protection garments are used

被引:5
|
作者
Carinou, Eleftheria [1 ]
Kollaard, Robert [2 ]
Petrovic, Jelena Stankovic [3 ]
Ginjaume, Merce [4 ]
机构
[1] Greek Atom Energy Commiss EEAE, Athens, Greece
[2] Nucl Res & Consultancy Grp NRG, POB 9034, NL-6800 ES Arnhem, Netherlands
[3] Univ Belgrade, Vinca Inst Nucl Sci, MP Alasa 12-14, Belgrade 11351, Serbia
[4] Univ Politecn Cataluna, Inst Tecn Energet, Avda Diagonal 647, E-08028 Barcelona, Spain
关键词
effective dose; equivalent dose to the lens of the eye; double dosimetry; regulatory status; INTERVENTIONAL RADIOLOGY;
D O I
10.1088/1361-6498/aaf456
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Following the proposal of the ICRP for the reduction of the dose limit for the lens of the eye, which has been adopted by the International Atomic Energy Agency and the European Council, concerns have been raised about the implementation of proper dose monitoring methods as defined in national regulations, and about the harmonisation between European countries. The European Radiation Dosimetry Group organised a survey at the end of 2017, through a web questionnaire, regarding national dose monitoring regulations. The questions were related to: double dosimetry, algorithms for the estimation of the effective dose, methodology for the determination of the equivalent dose to the lens of the eye and structure of the national dose registry. The results showed that more than 50% of the countries that responded to the survey have legal requirements about the number and the position of dosemeters used for estimation of the effective dose when radiation protection garments are used. However, in only five out of 26 countries are there nationally approved algorithms for the estimation of the effective dose. In 14 out of 26 countries there is a legal requirement to estimate the dose to the lens of the eye. All of the responding countries use some kind of national database for storing individual monitoring data but in only 12 out of 26 countries are the estimated effective dose values stored. The personal dose equivalent at depth 3 mm is stored in the registry of only seven out of 26 countries. From the survey, performed just before the implementation of the European Basic Safety Standards Directive, it is concluded that national occupational exposure frameworks require intensive and immediate work under the coordination of the competent authorities to bring them into line with the latest basic safety standards and achieve harmonisation between European countries.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 38 条
  • [1] Status of eye lens radiation dose monitoring in European hospitals
    Carinou, Eleftheria
    Ginjaume, Merce
    O'Connor, Una
    Kopec, Renata
    Merce, Marta Sans
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (04) : 729 - 739
  • [2] THE CHALLENGES IN THE ESTIMATION OF THE EFFECTIVE DOSE WHEN WEARING RADIOPROTECTIVE GARMENTS
    Vargas, C. Saldarriaga
    Struelens, L.
    Vanhavere, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 101 - 111
  • [3] APPLICATION OF EFFECTIVE DOSE EQUIVALENT TO RADIATION PROTECTION PRACTICE
    FUKUSHIMA, A
    YOSHIZAWA, Y
    [J]. HEALTH PHYSICS, 1982, 42 (05): : 742 - 742
  • [4] Space radiation protection: Comparison of effective dose to bone marrow dose equivalent
    Hoff, JL
    Townsend, LW
    Zapp, EN
    [J]. JOURNAL OF RADIATION RESEARCH, 2002, 43 : S125 - S128
  • [5] THE MEANING AND THE PRINCIPLE OF DETERMINATION OF THE EFFECTIVE DOSE EQUIVALENT IN RADIATION PROTECTION
    DREXLER, G
    WILLIAMS, G
    ZANKL, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1985, 12 (02) : 95 - 100
  • [6] Radiation protection measures to reduce the eye lens dose in spinal surgery
    Klingler, Jan-Helge
    Hoedlmoser, Herbert
    Naseri, Yashar
    [J]. SPINE JOURNAL, 2021, 21 (08): : 1243 - 1245
  • [7] Occupational radiation dose and protection to the eye lens for interventional cardiology operators
    Lian, Meng-En
    Wu, Guan-Yi
    Chao, Min-Fang
    Wang, Chong-Sheng
    Miao, Hsiao-Chien
    Tsai, Ming-Sung
    Hsieh, Mu-Yang
    Chen, Yeh-Peng
    Chu, Chun-Yuan
    Chang, Szu-Li
    Tsai, Hui-Yu
    [J]. RADIATION MEASUREMENTS, 2022, 154
  • [8] Practical guidelines for personal monitoring and estimation of effective dose and dose to the lens of the eye in interventional procedures
    Askounis, Panagiotis
    Gonzalez, Anna Torras
    Ginjaume, Merce
    Carinou, Eleftheria
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [9] Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry
    Patino, G.
    Alaman, C.
    Luquero, N.
    Ballester, F.
    Vijande, J.
    Diez, S.
    [J]. 2016 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2016,
  • [10] Regulatory implementation of the occupational equivalent dose limit for the lens of the eye and underlying relevant efforts in Japan
    Yokoyama, Sumi
    Hamada, Nobuyuki
    Tsujimura, Norio
    Kunugita, Naoki
    Nishida, Kazutaka
    Ezaki, Iwao
    Kato, Masahiro
    Okubo, Hideki
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2023, 99 (04) : 604 - 619