Drug-Eluting Stents Versus Bare-Metal Stents in Saphenous Vein Graft Interventions A Systematic Review and Meta-Analysis

被引:45
|
作者
Wiisanen, Matthew E. [1 ]
Abdel-Latif, Ahmed [1 ]
Mukherjee, Debabrata [1 ]
Ziada, Khaled M. [1 ]
机构
[1] Univ Kentucky, Gill Heart Inst, Div Cardiovasc Med, Lexington, KY 40536 USA
关键词
bare-metal stent(s); drug-eluting stent(s); meta-analysis; percutaneous coronary intervention; saphenous vein graft; PERCUTANEOUS CORONARY INTERVENTION; ANGIOGRAPHIC FOLLOW-UP; LONG-TERM OUTCOMES; INTRAVASCULAR ULTRASOUND; COST-EFFECTIVENESS; BYPASS GRAFTS; IMPLANTATION; IMMEDIATE; EFFICACY; DISEASE;
D O I
10.1016/j.jcin.2010.08.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to review the published data and perform a meta-analysis to reach robust conclusions in the comparison between bare-metal stents (BMS) and drug-eluting stents (DES) in saphenous vein graft (SVG) percutaneous coronary interventions (PCIs). Background Drug-eluting stents are superior to BMS in reducing major adverse cardiac events (MACE) after PCI in native coronary arteries. However, studies comparing BMS with DES in PCI of SVG have had mixed results, probably due to smaller numbers and the nonrandomized nature of most of them. Methods The published reports search identified 4 randomized controlled trials and 19 cohort studies comparing BMS with DES in SVG interventions. Clinical end point data were abstracted and analyzed in aggregate and in subgroup analyses with random-effects model. Results Patients receiving DES had a lower risk of mortality (odds ratio [Or] 0.75; confidence interval [CI]: 0.59 to 0.96), target lesion revascularization (TLR) (OR: 0.57; CI: 0.40 to 0.82), target vessel revascularization (TVR) (OR: 0.56; CI: 0.40 to 0.77), and MACE (OR: 0.61; CI: 0.42 to 0.79). Drug-eluting stent use resulted in a significant absolute risk reduction in TLR (-0.07; CI: -0.11 to -0.03), TVR (-0.10; CI: -0.15 to -0.05), and MACE (-0.12; CI: -0.18 to -0.06). There was no significant difference between the groups in recurrent myocardial infarction (OR: 0.99; CI: 0.65 to 1.51) or stent thrombosis (OR: 0.78; CI: 0.40 to 1.52). Conclusions In this meta-analysis comparing DES with BMS use in PCI of SVG lesions, DES use was associated with improved mortality, MACE, TLR, and TVR. There was no evidence of increased risk of myocardial infarction or stent thrombosis. (J Am Coll Cardiol Intv 2010;3:1262-73) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1262 / 1273
页数:12
相关论文
共 50 条
  • [1] Drug-eluting stents versus bare-metal stents for saphenous vein graft interventions
    Shah, Rahman
    Hesterberg, Kirstin
    [J]. JOURNAL OF THORACIC DISEASE, 2019, 11 : S1257 - S1260
  • [2] Bare Metal Versus Drug-Eluting Stents for Saphenous Vein Graft Interventions: A Systematic Review and Meta-Analysis
    Malik, Qasim
    Saqib, Najam
    Pir, Muhammad Siddique
    Mian, Raza
    Prutzman, David
    Durkin, Raymond
    Shirani, Jamshid
    Puleo, Peter
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B664 - B664
  • [3] Comparison of Drug-Eluting Stents With Bare-Metal Stents for PCI of Saphenous Vein Graft Lesions: Systematic Review and Meta-Analysis
    Mosleh, Wassim
    Gandhi, Sumeet
    Elsiddig, Mohamed
    Schwalm, Jon-David
    Farkouh, Michael E.
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (12): : E139 - E169
  • [4] Drug-eluting Stents Versus Bare-metal Stents for Saphenous Vein Graft Interventions: A Systematic Review and Meta-analysis of Studies With Longer Follow-up
    Garg, Aakash
    Rout, Amit
    Tayal, Raj
    Sharma, Abhishek
    Agrawal, Sahil
    Kostis, John B.
    Cohen, Marc
    Sharma, Samin
    Wasty, Najam
    [J]. CURRENT PROBLEMS IN CARDIOLOGY, 2021, 46 (01)
  • [5] Drug-eluting versus bare-metal stents in saphenous vein graft lesions
    Brilakis, Emmanouil S.
    Banerjee, Subhash
    Shunk, Kendrick A.
    Bhatt, Deepak L.
    [J]. LANCET, 2012, 379 (9816): : 615 - 615
  • [6] Drug-eluting versus bare-metal stents for saphenous vein graft lesions
    Conte, Sean M.
    Florisson, Daniel S.
    De Bono, Joshua A.
    Vale, Peter R.
    [J]. INTERNAL MEDICINE JOURNAL, 2019, 49 (12) : 1534 - 1537
  • [7] A Comprehensive Meta-analysis of Randomized Controlled Trials Comparing Drug-Eluting Stents with Bare-Metal Stents in Saphenous Vein Graft Interventions
    Hesterberg, Kirstin
    Jagadish, Pooja
    Butt, Asra
    Najib, Khalid
    Pathak, Aradhana
    Latham, Samuel
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B208 - B209
  • [8] A COMPREHENSIVE META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS COMPARING DRUG-ELUTING STENTS WITH BARE-METAL STENTS IN SAPHENOUS VEIN GRAFT INTERVENTIONS
    Hesterberg, K. G.
    Jagadish, P. S.
    Butt, A. K.
    Najib, K.
    Latham, S. B.
    Shah, R.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2019, 67 (02) : 583 - 584
  • [9] A comprehensive meta-analysis of randomized controlled trials comparing drug-eluting stents with bare-metal stents in saphenous vein graft interventions
    Shah, Rahman
    Jovin, Ion S.
    Latham, Samuel B.
    Hesterberg, Kirstin
    Heckle, Mark R.
    Rashid, Abdul
    Vetrovec, George W.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (07) : 1229 - 1236
  • [10] Trial Sequential Analysis of Drug-Eluting Stents Versus Bare-Metal Stents in Saphenous Vein Graft Intervention
    Kheiri, Babikir
    Osman, Mohammed
    Bachuwa, Ghassan
    Cigarroa, Joaquin E.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (05): : 823 - 824