Effect of low fluency dentin conditioning on tensile bond strength of composite bonded to Er:YAG laser-prepared dentin: a preliminary study

被引:28
|
作者
Bahrami, B. [1 ]
Askari, N. [1 ]
Tielemans, M. [1 ]
Heysselaer, D. [1 ]
Lamard, L. [2 ]
Peremans, A. [2 ]
Nyssen-Behets, C. [3 ]
Nammour, S. [1 ]
机构
[1] Univ Liege, Dept Dent Sci, Fac Med, Liege, Belgium
[2] Fac Univ Notre Dame Paix, LASMOS, B-5000 Namur, Belgium
[3] Catholic Univ Louvain, Expt Morphol Unit, B-1200 Brussels, Belgium
关键词
Composite; Er:YAG laser; Laser conditioning; Tensile bond strength; Thermally altered layer; ER-YAG-LASER; ELECTRON-MICROSCOPIC EVALUATION; PULSE REPETITION RATE; ABLATION; INTERFACE;
D O I
10.1007/s10103-010-0767-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several studies in the literature have previously shown that the bond strength of a composite bonded to dentin is almost equivalent as when dentin is prepared by either bur or Er:YAG laser. The aim of this preliminary study is to assess the hypothesis that dentin conditioning at low fluency by means of Er:YAG laser can improve the value of adhesion of composites resin to dentin. Sixty surfaces of caries-free human third molars extracted for orthodontic purposes were randomly divided into five groups of 12 teeth. The bur group was the control, prepared using bur, group L was prepared using Er:YAG 200 mJ, SSP (50 A mu s), 20 Hz, 15 seconds of sweeping, for groups L80, L100, L120, they were prepared first, with the same parameters of the group L 200, and then they received a conditioning, which is, respectively, 15 s of irradiations at: 80 mJ (SSP, 10 Hz), 100 mJ (SSP, 10 Hz), and 120 mJ (SSP, 10 Hz). All samples were restored in a single-component adhesive system: Xenon (DENTSPLY), and ceramX (DENTSPLY) as the resin composite. The specimens were submitted to tensile bond strength test using a universal testing machine. Data were submitted to statistical analysis using ANOVA coupled to a Tukey-Kramer test at the 95% level. The mean values in MPa were 33.3 for group B, 36.73 for group L 200, 41.7 for group L80, 37.9 for group L100, and 39.1 for group L120. Our results showed that dentin conditioning at a low fluency of 12.58 J/cm(2) per pulse, with 80 mJ output energy and 50-A mu s pulse duration can significantly improve tensile bond strength of a composite bonded to Er:YAG laser-prepared dentine.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [1] Effect of low fluency dentin conditioning on tensile bond strength of composite bonded to Er:YAG laser-prepared dentin: a preliminary study
    B. Bahrami
    N. Askari
    M. Tielemans
    D. Heysselaer
    L. Lamard
    A. Peremans
    C. Nyssen-Behets
    S. Nammour
    [J]. Lasers in Medical Science, 2011, 26 : 187 - 191
  • [2] Shear strength of composite bonded to Er:YAG laser-prepared dentin
    Visuri, SR
    Gilbert, JL
    Wright, DD
    Wigdor, HA
    Walsh, JT
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 (01) : 599 - 605
  • [3] Shear bond strength and SEM evaluation of composite bonded to Er:YAG laser-prepared dentin and enamel
    Dunn, WJ
    Davis, JT
    Bush, AC
    [J]. DENTAL MATERIALS, 2005, 21 (07) : 616 - 624
  • [4] Shear Bond Strength of Composite Bonded to Er, Cr:YSGG Laser-Prepared Dentin
    Gurgan, Sevil
    Kiremitci, Arlin
    Cakir, Filiz Yalcin
    Gorucu, Jale
    Alpaslan, Tugba
    Yazici, Esra
    Gutknecht, Norbert
    [J]. PHOTOMEDICINE AND LASER SURGERY, 2008, 26 (05) : 495 - 500
  • [5] Shear bond strength of different adhesives to Er:YAG laser-prepared dentin
    Celik, Esra Uzer
    Erguecue, Zeynep
    Tuerkuen, L. Sebnem
    Tuerkuen, Murat
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2006, 8 (05): : 319 - 325
  • [6] Shear bond strength of a self-etch adhesive to Er:YAG laser-prepared dentin
    Zhan, Zhenlin
    Wu, Weiliang
    Zhang, Xianzeng
    Zhao, Haibin
    Lin, Shi
    Xie, Shusen
    [J]. OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS IV, 2010, 7845
  • [7] Influence of pulse frequency Er:YAG laser on the tensile bond strength of a composite to dentin
    Gonçalves, MG
    Corona, SAM
    Borsatto, MC
    Pécora, JD
    Dibb, RGP
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2005, 18 (03): : 165 - 167
  • [8] Effect of Er: YAG Laser on Microtensile Bond Strength of Bleached Dentin to Composite
    Rezaei, Mohsen
    Aliasghar, Elham
    Rezvani, Mohammad Bagher
    Chiniforush, Nasim
    Moradi, Zohreh
    [J]. JOURNAL OF LASERS IN MEDICAL SCIENCES, 2019, 10 (02) : 117 - 124
  • [9] Shear bond strength of composite bonded to erbium:yttrium-aluminum-garnet laser-prepared dentin
    Gurgan, Sevil
    Kiremitci, Arlin
    Cakir, Filiz Yalcin
    Yazici, Esra
    Gorucu, Jale
    Gutknecht, Norbert
    [J]. LASERS IN MEDICAL SCIENCE, 2009, 24 (01) : 117 - 122
  • [10] Shear bond strength of composite bonded to erbium:yttrium-aluminum-garnet laser-prepared dentin
    Sevil Gurgan
    Arlin Kiremitci
    Filiz Yalcin Cakir
    Esra Yazici
    Jale Gorucu
    Norbert Gutknecht
    [J]. Lasers in Medical Science, 2009, 24 : 117 - 122