Paper-Based Bipolar Electrode Electrochemiluminescence Platform Combined with Pencil-Drawing Trace for the Detection of M.SssI Methyltransferase

被引:62
|
作者
Zhu, Lin [1 ]
Lv, Xue [1 ]
Yu, Haihan [1 ]
Tan, Xiaoran [1 ]
Rong, Yumeng [1 ]
Feng, Weihao [1 ]
Zhang, Lina [2 ]
Yu, Jinghua [1 ]
Zhang, Yan [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
45;
D O I
10.1021/acs.analchem.2c00803
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a hand-drawing paper-based bipolar electrode (BPE) electrochemiluminescence (ECL) platform for M.SssI methyltransferase (M.SssI MTase) assay was proposed via employing high electrocatalytic Pt@CeO2 as an ECL co-reaction accelerator and pencil-drawing graphite electric circuits as wires and electrodes. Notably, the introduction of pencil-drawing trace not only simplified the manufacturing process but also reduced the cost and saved fabricating time. Meanwhile, Pt@CeO2 with good electrocatalytic activity and satisfactory chemical stability was used at the anode of the closed BPE-ECL device to accelerate the oxidation rate of uric acid. Due to the balanced charges of the bipolar electrode, the ECL response of the MnS: CdS@ZnS/S2O82- system emitted on the cathode was enhanced. In situ growth of gold nanoparticles in the two electrode areas was convenient for DNA immobilization. With the above points in mind, the specific DNA double strands functionalized via Pt@CeO2 were employed to identify M.SssI MTase. The unmethylated DNA double strands were cut by HpaII endonuclease, resulting in the quenching of the ECL signal. Under the optimal conditions, sensitive detection of M.SssI MTase in a wide linear range of 0.01-100 U.mL(-1) with a satisfactory detection limit of 0.008 U.mL(-1) was realized. The reliable and versatile BPE-ECL tool for the determination of M.SssI MTase with easy-to-operate pencil-drawing traces and independent solution systems provides a new opportunity to develop paper-based devices applied in early disease diagnosis and pathogenesis research.
引用
收藏
页码:8327 / 8334
页数:8
相关论文
共 25 条
  • [1] Paper-Based Bipolar Electrode Electrochemiluminescence Platform for Detection of Multiple miRNAs
    Wang, Fangfang
    Liu, Yunqing
    Fu, Cuiping
    Li, Na
    Du, Miao
    Zhang, Lina
    Ge, Shenguang
    Yu, Jinghua
    ANALYTICAL CHEMISTRY, 2021, 93 (03) : 1702 - 1708
  • [2] Graphite paper-based bipolar electrode electrochemiluminescence sensing platform
    Zhang, Xin
    Ding, Shou-Nian
    BIOSENSORS & BIOELECTRONICS, 2017, 94 : 47 - 55
  • [3] Disposable paper-based bipolar electrode for sensitive electrochemiluminescence detection of a cancer biomarker
    Feng, Qiu-Mei
    Pan, Jian-Bin
    Zhang, Huai-Rong
    Xu, Jing-Juan
    Chen, Hong-Yuan
    CHEMICAL COMMUNICATIONS, 2014, 50 (75) : 10949 - 10951
  • [4] Paper-based closed Au-Bipolar electrode electrochemiluminescence sensing platform for the detection of miRNA-155
    Wang, Fangfang
    Fu, Cuiping
    Huang, Chuan
    Li, Na
    Wang, Yanhu
    Ge, Shenguang
    Yu, Jinghua
    BIOSENSORS & BIOELECTRONICS, 2020, 150
  • [5] A bipolar electrochemiluminescence sensing platform based on pencil core and paper reservoirs
    Lu, Wen-Xiu
    Bao, Ning
    Ding, Shou-Nian
    RSC ADVANCES, 2016, 6 (30): : 25388 - 25392
  • [6] Disposable paper-based bipolar electrode array for multiplexed electrochemiluminescence detection of pathogenic DNAs
    Qiumei Feng
    Hongyuan Chen
    Jingjuan Xu
    Science China(Chemistry) , 2015, (05) : 810 - 820
  • [7] Disposable paper-based bipolar electrode array for multiplexed electrochemiluminescence detection of pathogenic DNAs
    Feng, Qiumei
    Chen, Hongyuan
    Xu, Jingjuan
    SCIENCE CHINA-CHEMISTRY, 2015, 58 (05) : 810 - 818
  • [8] Disposable paper-based bipolar electrode array for multiplexed electrochemiluminescence detection of pathogenic DNAs
    Qiumei Feng
    Hongyuan Chen
    Jingjuan Xu
    Science China Chemistry, 2015, 58 : 810 - 818
  • [9] Disposable paper-based bipolar electrode array for multiplexed electrochemiluminescence detection of pathogenic DNAs
    Qiumei Feng
    Hongyuan Chen
    Jingjuan Xu
    Science China(Chemistry), 2015, 58 (05) : 810 - 820
  • [10] Paper-based solid-state supercapacitors with pencil-drawing graphite/polyaniline networks hybrid electrodes
    Yao, Bin
    Yuan, Longyan
    Xiao, Xu
    Zhang, Jing
    Qi, Yanyuan
    Zhou, Jing
    Zhou, Jun
    Hu, Bin
    Chen, Wen
    NANO ENERGY, 2013, 2 (06) : 1071 - 1078