Fracture resistance of single-rooted pulpless teeth using hybrid CAD/CAM blocks for post and core restoration

被引:0
|
作者
Passos, L. [1 ]
Barino, B. [2 ]
Laxe, L. [3 ]
Street, A. [4 ]
机构
[1] Fed Fluminense Univ, Hlth Inst Nova Friburgo, Sch Dent, Dept Prosthet Dent, Rua Doutor Silvio Henrique Braune 22, BR-28625650 Nova Friburgo, RJ, Brazil
[2] Univ Estado Rio De Janeiro, Sch Dent, Dept Endodont, Rio De Janeiro, Brazil
[3] Univ Estado Rio De Janeiro, Sch Dent, Dept Restorat Dent, Rio De Janeiro, Brazil
[4] Pontifical Catholic Univ Rio de Janeiro, Sch Engn, Elect Engn Dept, Rio De Janeiro, Brazil
关键词
CAD/CAM; post and core; anatomic posts; digital impression; fracture resistance; BOND STRENGTH; ENDODONTIC POSTS; CROWN FERRULE; FIBER POSTS; SYSTEMS; RETENTION; OPTIMIZES; SELECTION; STRESS; DENTIN;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to determine whether there is a significant difference in the fracture strengths of hybrid computer-aided design/computer-aided manufacturing (CAD/CAM) blocks and fiber posts for post and core restorations in both ferrule and nonferrule pulpless mandibular canines. Materials and method: Forty extracted human mandibular canines were divided into ferrule and nonferrule groups and restored with hybrid CAD/CAM blocks using either the CAD/CAM system or fiber posts (control). Thus, there were four subgroups of ten specimens each. A 45-degree oblique load was applied with a crosshead of 0.5 mm/min, and the fracture loads were recorded. The mode of fracture was evaluated using an optical microscope at 3x magnification, and the data were tabulated and statistically analyzed using the Mann-Whitney U test and the t test, respectively, for the existence of significant difference at a 0.05 significance level. Results: No statistically significant difference was found between the fracture strength under oblique loading when using hybrid CAD/CAM blocks and fiber posts in both ferrule and nonferrule groups. The failure mode distribution of the nonferrule group presented no unfavorable failures, whereas failures in the ferrule groups were spread out between the Favorable and Unfavorable groups. Conclusions: The results show that hybrid CAD/CAM blocks can be considered as an alternative restorative system in post and core restorations. Further basic and clinical research should be conducted to support the improvement of this system.
引用
收藏
页码:287 / 301
页数:15
相关论文
共 19 条
  • [1] Fabricated CAD/CAM Post-Core Using Glass Fiber-Reinforced Resin Shows Innovative Potential in Restoring Pulpless Teeth
    Suzaki, Naoko
    Yamaguchi, Satoshi
    Nambu, Eriko
    Tanaka, Ryousuke
    Imazato, Satoshi
    Hayashi, Mikako
    MATERIALS, 2021, 14 (20)
  • [2] Evaluating Fracture Resistance And Failure Modes Of Root Filled Teeth Restored With CAD/CAM-Fabricated Post And Core
    Alkhatri, Reem
    Saleh, Abdul Rahman Mohammed
    Kheder, Waad
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2019, 11 : 349 - 355
  • [3] Fracture resistance of endodontically treated teeth restored with CAD-CAM milled and prefabricated post-and-core systems
    Hamitoglu, Betul
    Ozkurt-Kayahan, Zeynep
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [4] CAD/CAM post-and-core using different esthetic materials: Fracture resistance and bond strengths
    Falcao Spina, Denis Roberto
    da Costa, Rogerio Goulart
    Farias, Isabelli Carolini
    da Cunha, Leonardo Goncalves
    Ritter, Andre Vicente
    Gonzaga, Carla Castiglia
    Correr, Gisele Maria
    AMERICAN JOURNAL OF DENTISTRY, 2017, 30 (06): : 299 - 304
  • [5] Influence of masticatory fatigue on the fracture resistance of the pulpless teeth restored with quartz-fiber post–core and crown
    Er-Min Nie
    Xia-Yun Chen
    Chun-Yuan Zhang
    Li-Li Qi
    Ying-He Huang
    International Journal of Oral Science, 2012, 4 : 218 - 220
  • [6] An in vitro study of the fracture resistance and the incidence of vertical root fracture of pulpless teeth restored with six post-and-core systems
    Sirimai, S
    Riis, DN
    Morgano, SM
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (03): : 262 - 269
  • [7] Influence of masticatory fatigue on the fracture resistance of the pulpless teeth restored with quartz-fiber post-core and crown
    Nie, Er-Min
    Chen, Xia-Yun
    Zhang, Chun-Yuan
    Qi, Li-Li
    Huang, Ying-He
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2012, 4 (04) : 218 - 220
  • [8] Influence of masticatory fatigue on the fracture resistance of the pulpless teeth restored with quartz-fiber post-core and crown
    Er-Min Nie
    Xia-Yun Chen
    Chun-Yuan Zhang
    Li-Li Qi
    Ying-He Huang
    International Journal of Oral Science, 2012, 4 (04) : 218 - 220
  • [9] Fracture resistance of CAD/CAM blocks cemented on dentin using different cementation strategies
    Anuntasainont, Munlika
    Po-ngam, Nanthiphorn
    Luhrs, Anne-Katrin
    Neoh, Siew Peng
    Pongprueksa, Pong
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 603 - 609
  • [10] Influence of masticatory fatigue on the fracture resistance of the pulpless teeth restored with quartz-fiber post-core and crown
    ErMin Nie
    XiaYun Chen
    ChunYuan Zhang
    LiLi Qi
    YingHe Huang
    International Journal of Oral Science, 2012, (04) : 218 - 220