Kilovoltage transit and exit dosimetry for a small animal image-guided radiotherapy system using built-in EPID

被引:10
|
作者
Anvari, Akbar [1 ]
Poirier, Yannick [1 ]
Sawant, Amit [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
dosimetry; EPID; image-guided radiotherapy; kilovoltage; preclinical; small animal; VERIFICATION; IRRADIATOR; TECHNOLOGY; DEVICE;
D O I
10.1002/mp.13134
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWe investigated the potential use of the built-in electronic portal imaging device (EPID) in the small animal radiation research platform (SARRP) as a dosimeter in the kV energy range. To this end, we developed a method for converting portal images to a two-dimensional (2D) dose maps at the detector plane and object's exit surface and validated them against empirical dose measurements. MethodsWe calibrated the SARRP's EPID to measure transit dose. The transit dose map was back-projected to calculate 2D dose distribution at the object's exit surface. The accuracy of transit and exit dose distributions was independently validated with a PinPoint ion chamber (IC) and Gafchromic EBT3 film measurements for a range of radiation dose rates (0.43-2.78 cGy/s), cone sizes (5-40 mm), in a homogeneous phantom of varying thickness (0-50 mm) and in an inhomogeneous phantom containing graphite, cork, air, and aluminum. ResultsIn-air central axis (CAX) transit dose values measured with the EPID showed close agreement with film and IC measurements. The maximum differences in EPID in-air transit measurements with film or IC measurements were 1%. The EPID was capable of accurately measuring phantom transit dose independently of the attenuating phantom thickness, with average discrepancies of 0.5% and 2.9% with IC and film, respectively, where the maximum difference between the EPID and the IC was 1.8%. The results were slightly worse for film, with maximum differences in 4.9%. Output factor measurements using EPID were within 2.9% of both IC and film measurements. In addition, calculated exit doses agreed with film values within 3.1%, for attenuating phantom thicknesses 15 mm. The agreement became worse with decreasing phantom thickness; for thicknesses of 10 and 5 mm, agreements were 5.7% and 6.9%, respectively. Compared to film, transit and exit profiles measured with the EPID showed average differences <2% for both homogeneous and inhomogeneous materials. ConclusionWe developed and validated a novel 2D transit/exit dosimetry for a kV SA-IGRT system using an EPID. We verified the accuracy of our method to measure EPID transit and exit dose distributions for a range of dose rates, beam attenuation, and collimation. Our results indicate that the EPID can be used as a simple, convenient device for kV dose delivery verification in small animal radiotherapy.
引用
收藏
页码:4642 / 4651
页数:10
相关论文
共 50 条
  • [1] Novel, EPID-Based Quality Assurance Framework for a Small Animal Image-Guided Radiotherapy System
    Anvari, A.
    Poirier, Y.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E601 - E602
  • [2] Small animal image-guided radiotherapy
    Verhaegen, Frank
    Vaz, Pedro
    Prise, Kevin M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):
  • [3] Small animal image-guided radiotherapy
    Prise, Kevin M.
    Verhaegen, Frank
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1069):
  • [4] Spatially Fractionated Radiotherapy using an Image-guided Small Animal Irradiation System
    Sharma, S.
    Webber, J.
    Koonce, N.
    Griffine, R. J.
    Penagaricano, J.
    Corry, P. M.
    Moros, E. G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S547 - S547
  • [5] Characterization of Inorganic Scintillator Detectors for Dosimetry in Image-Guided Small Animal Radiotherapy Platforms
    Silvestre Patallo, Ileana
    Subiel, Anna
    Carter, Rebecca
    Flynn, Samuel
    Schettino, Giuseppe
    Nisbet, Andrew
    [J]. CANCERS, 2023, 15 (03)
  • [6] Implications of respiratory motion for small animal image-guided radiotherapy
    Hill, Mark A.
    Vojnovic, Borivoj
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1069):
  • [7] Image-guided radiotherapy using a mobile kilovoltage x-ray device
    Sorensen, SP
    Chow, PE
    Kriminski, S
    Medin, PM
    Solberg, TD
    [J]. MEDICAL DOSIMETRY, 2006, 31 (01) : 40 - 50
  • [8] Validation of a Preclinical KV Treatment Planning System for Small Animal Image-Guided Radiotherapy
    Anvari, A.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E664 - E664
  • [9] Dose reduction potential of using gold fiducial markers for kilovoltage image-guided radiotherapy
    Takei, Yoshiki
    Monzen, Hajime
    Tamura, Mikoto
    Doi, Hiroshi
    Nishimura, Yasumasa
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (10): : 151 - 157
  • [10] Small animal image-guided radiotherapy: A new era for preclinical studies
    Delpon, G.
    Frelin-Labalme, A. -M.
    Heinrich, S.
    Beaudouin, V.
    Noblet, C.
    Begue, M.
    Le Deroff, C.
    Pouzoulet, F.
    Chiavassa, S.
    [J]. CANCER RADIOTHERAPIE, 2016, 20 (01): : 43 - 53