Vibration measurements by pulsed digital holographic endoscopy

被引:3
|
作者
Schedin, S [1 ]
Pedrini, G [1 ]
López, CP [1 ]
Mendoza-Santoyo, F [1 ]
机构
[1] Umea Univ, Dept Appl Phys & Elect, SE-90187 Umea, Sweden
关键词
pulsed digital holography; fibre optic endoscope; dynamic measurements; vibrations analysis; non-destructive testing;
D O I
10.1117/12.611745
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Digital holographic interferometry in combination with a flexible fiber endoscope allows high precision measurements of deformations on hidden objects surfaces, inside cavities and objects with small access apertures. A digital holographic endoscopy system is described with a frequency-doubled, twin oscillator Q-switched pulsed Nd:YAG laser as light source. A sequence of digital hologram pairs are recorded with a maximum repetition rate of 260 ms. Each digital hologram is captured at separate video frames of a CCD-camera. The time separation between the laser pulses from each cavity can be set in the range from 50 to 500 mu s. The digital holograms are transferred to a PC via a frame grabber and evaluated quantitatively by the Fourier transform method. The resulting phase fringe pattern has the information needed to evaluate quantitatively the amount of the deformation. Experimental results of vibration measurements of hidden mechanical and biological object surfaces are presented. The quality of the results obtained by mechanical object surfaces is usually higher than for biological surfaces. This can be explained easily by the fact that a biological surface is much more complex than a mechanical surface in the sense that some parts of the surface may reflect the light well whereas other parts may absorb the light. Also, biological surfaces are translucent, which means that part of the light may enter inside the sample where it may be absorbed or reflected.
引用
收藏
页码:729 / 734
页数:6
相关论文
共 50 条
  • [1] DIGITAL DOUBLE-PULSED HOLOGRAPHIC-INTERFEROMETRY FOR VIBRATION ANALYSIS
    PEDRINI, G
    ZOU, YL
    TIZIANI, HJ
    JOURNAL OF MODERN OPTICS, 1995, 42 (02) : 367 - 374
  • [2] Vibration Modes Study of Defective Eardrum Realized Using Digital Holographic Endoscopy
    Ding, Jianwen
    Zhou, Wenjing
    Yu, Yingjie
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (15):
  • [3] PULSED DIFFERENTIAL HOLOGRAPHIC MEASUREMENTS OF VIBRATION MODES OF HIGH-TEMPERATURE PANELS.
    Evensen, D.A.
    Aprahamian, R.
    Overoye, K.R.
    1600,
  • [4] Digital holographic interferometry for simultaneous orthogonal radial vibration measurements along rotating shafts
    Tatar, Kourosh
    Gren, Per
    Lycksam, Henrik
    APPLIED OPTICS, 2008, 47 (18) : 3269 - 3274
  • [5] Single-pulsed digital holographic topometry
    Hirsch, Sven
    Heintz, Stephanie
    Thelen, Andrea
    Gisbert, Nicola
    Hering, Peter
    NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS III, 2007, 6631
  • [6] Use of endoscopes in pulsed digital holographic interferometry
    Pedrini, G
    Schedin, S
    Alexeenko, I
    Tiziani, HJ
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION II: APPLICATIONS IN PRODUCTION ENGINEERING, 2001, 4399 : 1 - 8
  • [7] Digital holographic interferometry for shape and vibration analysis
    Tiziani, HJ
    Pedrini, G
    INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS: ADVANCES AND APPLICATIONS, 1997, 2921 : 282 - 287
  • [8] INTERFEROMETRIC MEASUREMENTS OF RESISTANCE TO VIBRATION OF A HOLOGRAPHIC STAND
    MIROVITSKII, DI
    SHANIN, VI
    SAMSONOV, GA
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1972, (04): : 191 - +
  • [9] Pulsed digital holography for vibration analysis
    Tiziani, HJ
    Pedrini, G
    Froning, P
    INTERNATIONAL CONFERENCE ON APPLIED OPTICAL METROLOGY, 1998, 3407 : 210 - 216
  • [10] An optimized interferometer for 3D digital holographic endoscopy
    Osten, W
    Kolenovic, E
    Klattenhoff, R
    Köpp, N
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION III, 2003, 5144 : 150 - 161