Luminance calculation method accounting for mesopic vision and fog penetration ability

被引:5
|
作者
Qin, Li [1 ]
Shi, Xuhua [1 ]
Leon, Arturo S. [2 ]
机构
[1] Ningbo Univ, Dept Informat Sci & Engn, Ningbo 315211, Peoples R China
[2] Florida Int Univ, Coll Engn & Comp, Dept Civil & Environm Engn, Miami, FL 33174 USA
基金
中国国家自然科学基金;
关键词
D O I
10.1364/AO.59.000683
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new luminance calculation method that accounts for mesopic vision and fog penetration ability is presented. This method aims to select a suitable light source for street lighting and is obtained using the mesopic luminance calculation and transmittance calculation methods at each individual wavelength. Additionally, the new method was evaluated using six LED light sources between 3500 and 6000 K. Overall, the calculation results indicate that suitable LEDs' CCT decreases with an increase of luminance for low transmittance rates. However, for high transmittance rates, high CCT LED lamps are the most suitable for street lighting. The recommended CCT of LED light sources for street lighting under different visibility and luminance conditions is presented. (C) 2020 Optical Society of America.
引用
收藏
页码:683 / 686
页数:4
相关论文
共 50 条
  • [1] Mesopic vision characteristics at decreased contrast in fog
    Ozolinsh, M.
    Colomb, M.
    Lauva, D.
    Fomins, S.
    Morange, P.
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS IV, 2010, 7853
  • [2] Study on the equivalent luminance of luminous fibers in mesopic vision
    Yan, Yanhong
    Gu, Bingfei
    Du, Lei
    Zhu, Yanan
    JOURNAL OF THE TEXTILE INSTITUTE, 2019, 110 (02) : 311 - 316
  • [3] A modification of the mesopic luminance equation in the cie mesopic photometry system for a better representation of the mesopic vision in the whole visual field
    Morimoto K.
    Nie D.X.
    Akash Y.
    Journal of Environmental Engineering (Japan), 2017, 82 (732): : 113 - 119
  • [4] M/P RATIO METHOD FOR MESOPIC LUMINANCE MEASUREMENT
    Uchida, T.
    Ohno, Y.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 402 - 409
  • [5] A Study on the Luminance of Landscape Lighting of Chinese Classical Architectures Based on Mesopic Vision
    Sun, Liye
    Liu, Gang
    Hai, Hong
    GREEN BUILDING TECHNOLOGIES AND MATERIALS, 2011, 224 : 175 - +
  • [6] Calculation of Mesopic Luminance Using per Pixel S/P Ratios Measured with Digital Imaging
    Maksimainen, Mikko
    Kurkela, Matti
    Bhusal, Pramod
    Hyyppa, Hannu
    LEUKOS, 2019, 15 (04) : 309 - 317
  • [7] A METHOD OF LUMINANCE CALCULATION IN AN ANISOTROPIC DIFFUSE REFLECTING INTERIOR
    UETANI, Y
    MATSUURA, K
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1993, 22 (02): : 166 - 175
  • [8] Method for the determination of the luminance of two-photon vision stimuli
    Kaczkos, Oliwia
    Zielinska, Agnieszka
    Pniewski, Jacek
    Wojtkowski, Maciej
    Komar, Katarzyna
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (10): : 5818 - 5830
  • [9] PECULIARITIES OF CALCULATION FOR A PROPOSITIVE METHOD OF ACCOUNTING COSTS
    Zhumabekova, G. Zh.
    BULLETIN OF THE NATIONAL ACADEMY OF SCIENCES OF THE REPUBLIC OF KAZAKHSTAN, 2018, (01): : 131 - 135
  • [10] Applied calculation method for penetration of projectile into rock
    Chen Shi-lin
    Wang De-rong
    Tan Ke-ke
    ROCK AND SOIL MECHANICS, 2007, 28 (06) : 1103 - 1107