A comparison between stereophotogrammetry and smartphone structured light technology for three-dimensional face scanning

被引:36
|
作者
D'Ettorre, Giorgio [1 ]
Farronato, Marco [2 ]
Candida, Ettore [1 ]
Quinzi, Vincenzo [3 ]
Grippaudo, Cristina [4 ,5 ]
机构
[1] Univ Cattolica Sacro Cuore, Dent Inst, Orthodont Head & Neck Dept, Rome, Italy
[2] Univ Milan, Osped Maggiore Policlin, Dept Med Surg & Dent, Fdn IRCCS IRCCS Ist Ricovero & Cura Carattere Sci, Via Commenda 10, I-20122 Milan, Italy
[3] Univ Aquila, Sect Orthodont, Dept Life Hlth & Environm Sci, Laquila, Italy
[4] Fdn Policlin Univ A Gemelli IRCCS, Dent Inst, Head & Neck Dept, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Dent Inst, Neck Dept, Rome, Italy
关键词
Stereophotogrammetry; Orthodontics; Facial scan; REPRODUCIBILITY; VALIDATION; RELIABILITY; ACCURACY;
D O I
10.2319/040921-290.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare three-dimensional facial scans obtained by stereophotogrammetry with two different applications for smartphone supporting the TrueDepth system, a structured light technology. Materials and Methods: Facial scans of 40 different subjects were acquired with three different systems. The 3dMDtrio Stereophotogrammetry System (3dMD, Atlanta, Ga) was compared with a smartphone (iPhone Xs; Apple, Cupertino, Calif) equipped with the Bellus3D Face Application (version 1.6.11; Bellus3D Inc, Campbell, Calif) or Capture (version 1.2.5; Standard Cyborg Inc, San Francisco, Calif). Times of image acquisition and elaboration were recorded. The surface-to-surface deviation and the distance between 18 landmarks from 3dMD reference images to those acquired with Bellus3D or Capture were measured. Results: Capturing and processing times with the smartphone applications were considerably longer than with the 3dMD system. The surface-to-surface deviation analysis between the Bellus3D and 3dMD showed an overlap percentage of 80.01% +/- 5.92% and 56.62% +/- 7.65% within the ranges of 1 mm and 0.5 mm discrepancy, respectively. Images from Capture showed an overlap percentage of 81.40% +/- 9.59% and 56.45% +/- 11.62% within the ranges of 1 mm and 0.5 mm, respectively. Conclusions: The face image acquisition with the 3dMD device is fast and accurate, but bulky and expensive. The new smartphone applications combined with the TrueDepth sensors show promising results. They need more accuracy from the operator and more compliance from the patient because of the increased acquisition time. Their greatest advantages are related to cost and portability.
引用
收藏
页码:358 / 363
页数:6
相关论文
共 50 条
  • [1] Three-dimensional human face laser scanning based on three-line structured light
    Key Laboratory of Opto-Electronics Information Science and Technology, College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China
    [J]. Zhongguo Jiguang, 1600, 6 (1594-1598):
  • [2] Computer-generated three-dimensional modeling using passive stereophotogrammetry and structured light scanning for craniomaxillofacial imaging
    Kantor, Jonathan
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2017, 70 (12): : 1776 - 1777
  • [4] Comparison of the accuracy of digital stereophotogrammetry and projection moire profilometry for three-dimensional imaging of the face
    Artopoulos, A.
    Buytaert, J. A. N.
    Dirckx, J. J. J.
    Coward, T. J.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (05) : 654 - 662
  • [5] Three-dimensional measurement of human face with structured-light illumination
    Carnicky, J
    Chorvat, D
    [J]. Measurement 2005, Proceedings, 2005, : 145 - 148
  • [6] Three-dimensional Scanning System with Double Structured-light Sensors
    Peng, Bin
    Tan, Haishu
    Zhou, Fuqiang
    [J]. VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 1938 - +
  • [7] Effects of Artificial Extraoral Markers on Accuracy of Three-Dimensional Dentofacial Image Integration: Smartphone Face Scan versus Stereophotogrammetry
    Mai, Hang-Nga
    Lee, Du-Hyeong
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (03):
  • [8] Validation of three-dimensional facial imaging captured with smartphone-based photogrammetry application in comparison to stereophotogrammetry system
    Andrews, James
    Alwafi, Abdulraheem
    Bichu, Yashodhan M.
    Pliska, Benjamin T.
    Mostafa, Nesrine
    Zou, Bingshuang
    [J]. HELIYON, 2023, 9 (05)
  • [9] Face Feature Detection Based on Structured Light Projection Three-Dimensional Reconstruction
    Xia Chenxu
    Hao Qun
    Zhang Yiming
    Zhang Shaohui
    Li Fanfei
    Yang Zhihui
    Sun Jiankun
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (22)
  • [10] Passive Stereophotogrammetry and Structured Light Scanning for 3-Dimensional Imaging in Dermatologic Surgery
    Kantor, Jonathan
    [J]. DERMATOLOGIC SURGERY, 2020, 46 (06) : 855 - 856