Monte Carlo simulation of the imaging properties of scintillator-coated X-ray pixel detectors

被引:9
|
作者
Hjelm, M [1 ]
Norlin, B
Nilsson, HE
Fröjdh, C
Badel, X
机构
[1] Mid Sweden Univ, Dept Informat Technol & Media, SE-85170 Sundsvall, Sweden
[2] Royal Inst Technol, Dept Microelect & Informat Technol, SE-16440 Kista, Sweden
关键词
X-ray; signal-to-noise ratio; Monte Carlo simulation; imaging; pixel detector; scintillating screen;
D O I
10.1016/S0168-9002(03)01553-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The spatial resolution of scintillator-coated X-ray pixel detectors is usually limited by the isotropic light spread in the scintillator. One way to overcome this limitation is to use a pixellated scintillating layer on top of the semiconductor pixel detector. Using advanced etching and filling techniques, arrays of CsI columns have been successfully fabricated and characterized. Each CsI waveguide matches one pixel of the semiconductor detector, limiting the spatial spread of light. Another concept considered in this study is to detect the light emitted from the scintillator by diodes formed in the silicon pore walls. There is so far no knowledge regarding the theoretical limits for these two approaches, which makes the evaluation of the fabrication process difficult. In this work we present numerical calculations of the signal-to-noise ratio (SNR) for detector designs based on scintillator-filled pores in silicon. The calculations are based on separate Monte Carlo (MC) simulations of X-ray absorption and light transport in scintillator waveguides. The resulting data are used in global MC simulations of flood exposures of the detector array, from which the SNR values are obtained. Results are presented for two scintillator materials, namely CsI (Tl) and GADOX. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 50 条
  • [1] Monte Carlo simulation of the transient response of single photon absorption in X-ray pixel detectors
    Nilsson, HE
    Dubaric, E
    Hjelm, M
    Englund, U
    [J]. MATHEMATICS AND COMPUTERS IN SIMULATION, 2003, 62 (3-6) : 471 - 478
  • [2] Resolution and noise properties of scintillator coated X-ray detectors
    Dubaric, E
    Fröjdh, C
    Nilsson, HE
    Petersson, CS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 178 - 182
  • [3] Uncertainty of Monte Carlo variance estimates: application to the simulation of x-ray imaging detectors
    Badano, Aldo
    Samuelson, Frank W.
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [4] Hybridmantis: A Novel Method for Faster Monte Carlo Simulation of X-Ray Imaging Detectors
    Sharma, D.
    Badal, A.
    Fang, Y.
    Badano, A.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Monte Carlo Simulation of an X-Ray Pixel Beam Microirradiation System
    Schreiber, E. C.
    Chang, S. X.
    [J]. RADIATION RESEARCH, 2009, 171 (03) : 332 - 341
  • [6] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [7] X-ray microanalysis of a coated nonconductive specimen: Monte Carlo simulation
    Demers, H
    Gauvin, R
    [J]. MICROSCOPY AND MICROANALYSIS, 2004, 10 (06) : 776 - 782
  • [8] Imaging theory for X-ray pixel detectors
    Anton, G
    Durst, J
    Firsching, M
    Giersch, J
    Korn, A
    Mitschke, M
    Niederlhöner, D
    Pfeiffer, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 116 - 123
  • [9] X-ray fluorescence imaging with pixel detectors
    Tichy, V.
    Holy, T.
    Jakubek, J.
    Linhart, V.
    Pospisil, S.
    Vykydal, Z.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 67 - 70
  • [10] Energy discrimination with an X-ray pixel detector - a Monte-Carlo simulation
    Pedersen, F
    Ronnqvist, C
    Fransson, K
    Gustafsson, L
    Kullander, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 443 - 447