LWIR NUC Using an Uncooled Microbolometer Camera

被引:3
|
作者
LaVeigne, Joe [1 ]
Franks, Greg [1 ]
Sparkman, Kevin [1 ]
Prewarski, Marcus [1 ]
Nehring, Brian [1 ]
McHugh, Steve [1 ]
机构
[1] Santa Barbara Infrared Inc, Santa Barbara, CA 93103 USA
关键词
Scene Projection; LFRA; Mirage XL; LWIR; NUC; microbolometer; IRSP;
D O I
10.1117/12.850524
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Performing a good non-uniformity correction is a key part of achieving optimal performance from an infrared scene projector. Ideally, NUC will be performed in the same band in which the scene projector will be used. Cooled, large format MWIR cameras are readily available and have been successfully used to perform NUC, however, cooled large format LWIR cameras are not as common and are prohibitively expensive. Large format uncooled cameras are far more available and affordable, but present a range of challenges in practical use for performing NUC on an IRSP. Santa Barbara Infrared, Inc. reports progress on a continuing development program to use a microbolometer camera to perform LWIR NUC on an IRSP. Camera instability and temporal response and thermal resolution are the main difficulties. A discussion of processes developed to mitigate these issues follows.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Enhanced LWIR NUC Using an Uncooled Microbolometer Camera
    LaVeigne, Joe
    Franks, Greg
    Sparkman, Kevin
    Prewarski, Marcus
    Nehring, Brian
    TECHNOLOGIES FOR SYNTHETIC ENVIRONMENTS: HARDWARE-IN-THE-LOOP XVI, 2011, 8015
  • [2] Amber's uncooled microbolometer LWIR camera
    Meyer, B
    Cannata, R
    Stout, A
    Gin, A
    Taylor, P
    Woodbury, E
    Deffner, J
    Ennerson, F
    INFRARED DETECTORS AND FOCAL PLANE ARRAYS IV, 1996, 2746 : 13 - 22
  • [3] Quantitative thermal nondestructive evaluation using an uncooled microbolometer infrared camera
    Zalameda, JN
    Winfree, WP
    THERMOSENSE XXIV, 2002, 4710 : 610 - 617
  • [4] Microbolometer uncooled infrared camera with 20 mK NETD
    Radford, W
    Wyles, R
    Wyles, J
    Ray, M
    Kennedy, A
    Finch, A
    Moody, E
    Cheung, F
    Coda, R
    Baur, S
    INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 636 - 646
  • [5] UNCOOLED SIxGEyO1-x-y MICROBOLOMETER STACK FOR LWIR DETECTION
    Abdullah, Amjed
    Liu, Tao
    Kinzel, Edward
    Almasri, Mahmoud
    2020 33RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2020), 2020, : 161 - 164
  • [6] Challenges in using an analog uncooled microbolometer thermal camera to measure crop temperature
    Kusnierek, Krzysztof
    Korsaeth, Audun
    INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING, 2014, 7 (04) : 60 - 74
  • [7] Calibration of uncooled LWIR microbolometer imagers to enable long-term field deployment
    Nugent, Paul W.
    Shaw, Joseph A.
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XXV, 2014, 9071
  • [8] Microbolometer uncooled infrared camera with 20mK NETD
    Radford, W
    Murphy, D
    Finch, A
    Kennedy, A
    Kojiro, J
    Ray, M
    Wyles, R
    Coda, R
    Moody, E
    Baur, S
    INFRARED DETECTORS AND FOCAL PLANE ARRAYS V, 1998, 3379 : 22 - 35
  • [9] Radiometric cloud imaging with an uncooled microbolometer thermal infrared camera
    Shaw, JA
    Nugent, PW
    Pust, NJ
    Thurairajah, B
    Mizutani, K
    OPTICS EXPRESS, 2005, 13 (15): : 5807 - 5817
  • [10] Real time control of uncooled microbolometer camera transfer function
    Grimberg, E
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XV, 2004, 5407 : 168 - 180