摘要
PURPOSE. To develop an automated approach for segmenting the neural canal opening (NCO) and cup at the level of the retinal pigment epithelium (RPE)/Bruch's membrane (BM) complex in spectral-domain optical coherence tomography (SD-OCT) volumes. To investigate the correspondence and discrepancy between the NCO-based metrics and the clinical disc margin on fundus photographs of glaucoma subjects. METHODS. SD-OCT scans and corresponding stereo fundus photographs of the optic nerve head were obtained from 68 eyes of 34 patients with glaucoma or glaucoma suspicion. Manual planimetry was performed by three glaucoma experts to delineate a reference standard (RS) for cup and disc margins from the images. An automated graph-theoretic approach was used to identify the NCO and cup. NCO-based metrics were compared with the RS. RESULTS. Compared with the RS disc margin, the authors found mean unsigned and signed border differences of 2.81 +/- 1.48 pixels (0.084 +/- 0.044 mm) and -0.99 +/- 2.02 pixels (-0.030 +/- 0.061 mm), respectively, for NCO segmentation. The correlations of the linear cup-to-disc (NCO) area ratio, disc (NCO) area, rim area, and cup area of the algorithm with the RS were 0.85, 0.77, 0.69, and 0.83, respectively. CONCLUSIONS. In most eyes, the NCO-based 2D metrics, as estimated by the novel automated graph-theoretic approach to segment the NCO and cup at the level of the RPE/BM complex in SD-OCT volumes, correlate well with RS. However, a small discrepancy exists in NCO-based anatomic structures and the clinical disc margin of the RS in some eyes. (Invest Ophthalmol Vis Sci. 2010;51:5708-5717) DOI:10.1167/iovs.09-4838
引用
收藏
页码:5708 / 5717
页数:10
相关论文
共 50 条
  • [1] Automated Segmentation of Optic Nerve Head Structures With Optical Coherence Tomography
    Almobarak, Faisal A.
    O'Leary, Neil
    Reis, Alexandre S. C.
    Sharpe, Glen P.
    Hutchison, Donna M.
    Nicolela, Marcelo T.
    Chauhan, Balwantray C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (02) : 1161 - 1168
  • [2] Detection of Optic Nerve Head Neural Canal Opening within Histomorphometric and Spectral Domain Optical Coherence Tomography Data Sets
    Strouthidis, Nicholas G.
    Yang, Hongli
    Fortune, Brad
    Downs, J. Crawford
    Burgoyne, Claude F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (01) : 214 - 223
  • [3] Automated 3-D Segmentation of Intraretinal Layers from Optic Nerve Head Optical Coherence Tomography Images
    Antony, Bhavna J.
    Abramoff, Michael D.
    Lee, Kyungmoo
    Sonkova, Pavlina
    Gupta, Priya
    Kwon, Young
    Niemeijer, Meindert
    Hu, Zhihong
    Garvin, Mona K.
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [4] Evaluation of Automated Segmentation Algorithms for Optic Nerve Head Structures in Optical Coherence Tomography Images
    Duan, Xiangyun J.
    Jefferys, Joan L.
    Quigley, Harry A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (10) : 3816 - 3826
  • [5] Automated Segmentation of the Cup and Rim from Spectral Domain OCT of the Optic Nerve Head
    Abramoff, Michael D.
    Lee, Kyungmoo
    Niemeijer, Meindert
    Alward, Wallace L. M.
    Greenlee, Emily C.
    Garvin, Mona K.
    Sonka, Milan
    Kwon, Young H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) : 5778 - 5784
  • [6] Combined Use of High-Definition and Volumetric Optical Coherence Tomography for the Segmentation of Neural Canal Opening in Cases of Optic Nerve Edema
    Wang, Jui-Kai
    Kardon, Randy H.
    Garvin, Mona K.
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413
  • [7] Automated optic-nerve-head analysis using optical coherence tomography
    Kulkarni, MD
    Harman, J
    Kim, R
    Kirschbaum, AR
    Pedersen, P
    Everett, MJ
    Wei, J
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 : 237 - 239
  • [8] A joint estimation detection of Glaucoma progression in 3D spectral domain optical coherence tomography optic nerve head images
    Belghith, Akram
    Bowd, Christopher
    Weinreb, Robert N.
    Zangwill, Linda M.
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [9] Optic Nerve Head Diagnostics with Optical Coherence Tomography
    Unterlauft, J. D.
    Tegetmeyer, H.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (01) : 47 - 57
  • [10] Optical Coherence Tomography in Optic Nerve Head Avulsion
    Murchison, Ann P.
    Affel, Elizabeth L.
    Garg, Sunir J.
    Bilyk, Jurij R.
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2012, 31 (02): : 97 - 101