Longitudinal examination of cervical volume and vascularization changes during the antepartum and postpartum period using three-dimensional and power Doppler ultrasound

被引:0
|
作者
Yilmaz, Nur Cansu [1 ]
Yigiter, Alin Basguel [2 ]
Kavak, Zehra Nese [1 ]
Durukan, Birol [3 ]
Gokaslan, Husnu [1 ]
机构
[1] Marmara Univ, Fac Med, Fetal Med Unit, Dept Obstet & Gynecol, Istanbul, Turkey
[2] Istanbul Bilim Univ, Dept Obstet & Gynecol, European Florence Nightingale Hosp, Sch Med,Fetal Med Unit, Istanbul, Turkey
[3] Goztepe Educ & Res Hosp, Istanbul, Turkey
关键词
Cervical volume; pregnancy outcome; three-dimensional ultrasound; VOCAL; PRETERM DELIVERY; PREGNANT-WOMEN; PREDICTION; LENGTH; ULTRASONOGRAPHY; INTRAOBSERVER; PREECLAMPSIA; VELOCIMETRY; GESTATION; RISK;
D O I
10.1515/JPM.2010.087
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess longitudinally the changes in cervical volume and vascularization during the peripartum period using three-dimensional ultrasound (3D US) and power Doppler and to determine whether these measures change with gestational complications. Methods: Longitudinal measurements of cervical dimensions by transvaginal 3D US and power Doppler using the virtual organ computer-aided analysis program were performed at 11-14, 22-24, 32-34 weeks' gestation, and at 6 weeks' postpartum in 111 pregnant women. Comparisons were made between women who delivered at term (vs. preterm), nulliparous (vs. parous), with (vs. without) pre-eclampsia and those with (vs. without) gestational diabetes. Results: After establishing reference values for each peripartum period for cervical volume, vascularization index (VI) and flow index (FI), we found that the 2(nd) and 3(rd) trimester volume, 2(nd) trimester FI and postpartum VI were different in nulli- vs. multiparous women. Volume and vascularization parameters were unaffected by preterm labor. Second trimester VI and vascularization flow index values were lower in pre-eclamptic vs. non-pre-eclamptic women (P<0.05), but unaffected by gestational diabetes. Conclusion: Cervical volume and vascularization parameters are not helpful in predicting preterm labor and gestational diabetes, but might be associated with pre-eclampsia.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [1] Assessment of changes in volume and vascularity of the ovaries during the normal menstrual cycle using three-dimensional power Doppler ultrasound
    Jokubkiene, Ligita
    Sladkevicius, Povilas
    Rovas, Linas
    Valentin, Lil
    HUMAN REPRODUCTION, 2006, 21 (10) : 2661 - 2668
  • [2] Alteration of vascularization in preeclamptic placentas measured by three-dimensional power Doppler ultrasound
    Chen, Chen-Yu
    Wang, Kuo-Gon
    Chen, Chie-Pein
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2013, 26 (16): : 1616 - 1622
  • [3] Assessment of changes in endometrial and subendometrial volume and vascularity during the normal menstrual cycle using three-dimensional power Doppler ultrasound
    Jokubkiene, L.
    Sladkevicius, P.
    Rovas, L.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (06) : 672 - 679
  • [4] Assessment of placental volume and vascularization at 11-14 weeks of gestation in a Taiwanese population using three-dimensional power Doppler ultrasound
    Wang, Hsing-I
    Yang, Ming-Jie
    Wang, Peng-Hui
    Wu, Yi-Cheng
    Chen, Chih-Yao
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2014, 77 (12) : 648 - 652
  • [5] Reproducibility of the study of placental vascularization by three-dimensional power Doppler
    Mercé, LT
    Barco, MJ
    Bau, S
    JOURNAL OF PERINATAL MEDICINE, 2004, 32 (03) : 228 - 233
  • [6] Three-dimensional power Doppler ultrasound for the study of cervical cancer and precancerous lesions
    Belitsos, P.
    Papoutsis, D.
    Rodolakis, A.
    Mesogitis, S.
    Antsaklis, A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (05) : 576 - 581
  • [7] Ultrasonographic evaluation of pelvic floor structure at antepartum and postpartum periods using three-dimensional transperineal ultrasound
    Manabu Nishibayashi
    Ryugo Okagaki
    Journal of Medical Ultrasonics, 2021, 48 : 345 - 351
  • [8] Ultrasonographic evaluation of pelvic floor structure at antepartum and postpartum periods using three-dimensional transperineal ultrasound
    Nishibayashi, Manabu
    Okagaki, Ryugo
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (03) : 345 - 351
  • [9] Three-dimensional ultrasound and three-dimensional power Doppler in the assessment of ovarian tumors
    Laban, M.
    Metawee, H.
    Elyan, A.
    Kamal, M.
    Kamel, M.
    Mansour, G.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 99 (03) : 201 - 205
  • [10] Assessment of placental fractional moving blood volume using quantitative three-dimensional power Doppler ultrasound
    Yu, CH
    Chang, CH
    Ko, HC
    Chen, WC
    Chang, FM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (01): : 19 - 23