Electrochemical behavior and electrochemical determination of carbamazepine at an ionic liquid modified carbon paste electrode in the presence of sodium dodecyl sulfate

被引:27
|
作者
Liu, Li-Hong [1 ,2 ]
Duan, Cheng-Qian [1 ,3 ]
Gao, Zuo-Ning [1 ]
机构
[1] Ningxia Univ, Coll Chem & Chem Engn, Key Lab Energy Sources & Chem Engn, Yinchuan 750021, Peoples R China
[2] Heihe Coll, Dept Chem, Heihe 164300, Peoples R China
[3] Ningxia Med Univ, Higher Vocat Coll, Yinchuan 750004, Peoples R China
关键词
carbamazepine; sodium dodecyl sulfate; ionic liquid modified carbon paste electrode; electrochemistry; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC DETERMINATION; SELECTIVE DETERMINATION; ASCORBIC-ACID; URIC-ACID; CHROMATOGRAPHY; DOPAMINE; SURFACTANTS; METABOLITES; HEMOGLOBIN;
D O I
10.2298/JSC110420188L
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical behavior and electrochemical determination of carbamazepine (CBZ) at a hydrophobic ionic liquid 1-benzyl-3-methylimidazole hexafluorophosphate ([BnMIM]PF6) modified carbon paste electrode ([BnMIM]PF6/CPE) in the presence of sodium dodecyl sulfate (SDS) were investigated. A well-defined and sensitive oxidation peak was observed at the [BnMIM]PF6/CPE in the presence of SDS and a 0.10 M phosphate buffer solution (pH 6.80). The oxidation peak current of CBZ increased significantly at the [BnMIM]PF6/CPE in the presence of SDS compared with that in the absence of SDS at the carbon paste electrode. It suggested that both SDS and [BnMIM]PF6/CPE show an obvious enhancing effect on the electrochemical oxidation of CBZ. The electrochemical kinetic parameters for CBZ at the [BnMIM]PF6/CPE in aqueous SDS solutions were also determined by chronocoulometry and chronoamperometry. Finally, the experimental conditions were optimized, and a new electrochemical method for the determination for CBZ was established. The oxidation peak current was linearly dependent on the CBZ concentration in the range 7.0 mu M to 0.7 mM, with a detection limit of 0.98 mu M (signal to noise ratio, S/N = 3). The relative standard deviation for six determinations of 0.10 mM CBZ was between 1.40 and 2.13 %. The proposed method was applied in the determination of CBZ in commercial tablet samples.
引用
收藏
页码:483 / 496
页数:14
相关论文
共 50 条
  • [1] Electrochemical Behavior and Electrochemical Determination of Tiamulin Fumarate at an Ionic Liquid Modified Carbon Paste Electrode
    Liu, Li-Hong
    Duan, Cheng-Qian
    Gao, Zuo-Ning
    [J]. CROATICA CHEMICA ACTA, 2010, 83 (04) : 409 - 414
  • [2] Electrochemical behavior of labetalol at an ionic liquid-modified carbon paste electrode and its electrochemical determination
    Zhang, Yan-Mei
    Duan, Cheng-Qian
    Gao, Zuo-Ning
    [J]. JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (02) : 281 - 294
  • [3] Comparative investigation on electrochemical behavior of hydroquinone at carbon ionic liquid electrode, ionic liquid modified carbon paste electrode and carbon paste electrode
    Zhang, Ya
    Zheng, Jian Bin
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (25) : 7210 - 7216
  • [4] A new electrochemical method for the determination of trace molybdenum(VI) using carbon paste electrode modified with sodium dodecyl sulfate
    Deng, Pei-hong
    Feng, Yong-lan
    Fei, Jun-jie
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (02) : 367 - 373
  • [5] Electrochemical determination of tyrosine in the presence of uric acid at a carbon paste electrode modified with multi-walled carbon nanotubes enhanced by sodium dodecyl sulfate
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Delshad, Mona
    Khoobi, Asma
    [J]. CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (06): : 1824 - 1829
  • [6] Electrochemical investigations of an anticancer drug in the presence of sodium dodecyl sulfate as an enhancing agent at carbon paste electrode
    Nagappa L. Teradal
    Shankara S. Kalanur
    S. N. Prashanth
    Jaldappagari Seetharamappa
    [J]. Journal of Applied Electrochemistry, 2012, 42 : 917 - 923
  • [7] Electrochemical investigations of an anticancer drug in the presence of sodium dodecyl sulfate as an enhancing agent at carbon paste electrode
    Teradal, Nagappa L.
    Kalanur, Shankara S.
    Prashanth, S. N.
    Seetharamappa, Jaldappagari
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (11) : 917 - 923
  • [8] Electrochemical Studies of Mesalazine at Sodium Dodecyl Sulfate Modified Carbon Paste Electrode: A Cyclic Voltammetric Study
    Tanuja, S. B.
    Swamy, B. E. Kumara
    Pai, K. Vasantakumar
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (01): : 64 - 76
  • [9] Electrochemical behavior and determination of rutin on a pyridinium-based ionic liquid modified carbon paste electrode
    Sun, Wei
    Yang, Maoxia
    Li, Yinzhuo
    Jiang, Qiang
    Liu, Shufeng
    Jiao, Kui
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (05) : 1326 - 1331
  • [10] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657